Sachin Wani

Sachin Wani

Auto-generated profile, based on publicly available information

Sachin Wani

University of Colorado Health,Aurora,United States, USA

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2009 in American Journal of Gastroenterology
Verified
Journal Article
Closed access
PDF file
ARAmit Rastogi
Amit Rastogi
JKJohn Keighley
John Keighley
VSVikas Singh
Vikas Singh
PCPeggy Callahan
Peggy Callahan
ABAjay Bansal
Ajay Bansal
PSPrateek Sharma
Prateek Sharma
Standard white light colonoscopy has limited ability to differentiate between polyp types (adenomatous vs. hyperplastic). Narrow band imaging (NBI) highlights the superficial mucosal/vascular patterns on polyps and may facilitate real-time characterization of polyp histology. The aim of this study was to prospectively evaluate and compare the diagnostic characteristics of high-definition white light colonoscopy (HDWL) and NBI without magnification in the real-time prediction of polyp histology (adenomatous vs. hyperplastic) by evaluating the surface mucosal and vascular patterns. We conducted a prospective comparative study in a tertiary referral center. A total of 100 patients referred for screening or surveillance colonoscopy were prospectively enrolled and underwent colonoscopy using a high-definition colonoscope with NBI capability. Every polyp detected was initially evaluated with HDWL followed by NBI for the presence of surface mucosal/vascular patterns. Based on these patterns, polyp histology was predicted by both modalities. The main outcome measurements were: (i) diagnostic characteristics of HDWL and NBI in predicting polyp histology and (ii) impact of polyp size and learning effect (first half of study vs. second half) on the ability of NBI to predict adenomas. A total of 236 polyps were detected in 100 patients—143 adenomas, 77 hyperplastic, and 16 others. Surface patterns (type A: hyperplastic; type B: adenomatous) were recognized in all polyps with NBI (100%) compared to 45% with HDWL. For predicting adenomas, NBI had a significantly higher sensitivity and greater accuracy (96 and 93% respectively) compared with HDWL (38 and 61% respectively) (all P<0.0001). Although the accuracy of NBI for predicting adenomas improved with increasing polyp size (≤5 mm; 6–9 mm; ≥10 mm) and in the second half compared with the first half of the study, these differences were not statistically significant. Using a simple surface mucosal/vascular pattern classification, NBI without magnification was highly accurate and significantly superior to HDWL for the real-time prediction of adenomas.

1 November 2017 in Clinical Gastroenterology and Hepatology
Verified
Journal Article
Closed access
SWSachin Wani
Sachin Wani
RKRajesh Keswani
Rajesh Keswani
MHMatt Hall
Matt Hall
SHSamuel Han
Samuel Han
MAMeer Akbar Ali
Meer Akbar Ali
DEDayna S. Early
Dayna S. Early

1 February 2014 in Gastrointestinal Endoscopy
Verified
Journal Article
Closed access
SWSachin Wani
Sachin Wani
JDJennifer Drahos
Jennifer Drahos
MCMichael B. Cook
Michael B. Cook
ARAmit Rastogi
Amit Rastogi
ABAjay Bansal
Ajay Bansal
ADAnanya Das
Ananya Das

1 November 2018 in Gastroenterology
Verified
Journal Article
Open access
PDF file
SWSachin Wani
Sachin Wani
RKRajesh N. Keswani
Rajesh N. Keswani
SHSamuel Han
Samuel Han
EAEva M. Aagaard
Eva M. Aagaard
MHMatthew Hall
Matthew Hall
DEDayna Early
Dayna Early
It is unclear whether participation in competency-based fellowship programs for endoscopic ultrasound (EUS) and endoscopic retrograde cholangiopancreatography (ERCP) results in high-quality care in independent practice. We measured quality indicator (QI) adherence during the first year of independent practice among physicians who completed endoscopic training with a systematic assessment of competence. We performed a prospective multicenter cohort study of invited participants from 62 training programs. In phase 1, 24 advanced endoscopy trainees (AETs), from 20 programs, were assessed using a validated competence assessment tool. We used a comprehensive data collection and reporting system to create learning curves using cumulative sum analysis that were shared with AETs and trainers quarterly. In phase 2, participating AETs entered data into a database pertaining to every EUS and ERCP examination during their first year of independent practice, anchored by key QIs. By the end of training, most AETs had achieved overall technical competence (EUS 91.7%, ERCP 73.9%) and cognitive competence (EUS 91.7%, ERCP 94.1%). In phase 2 of the study, 22 AETs (91.6%) participated and completed a median of 136 EUS examinations per AET and 116 ERCP examinations per AET. Most AETs met the performance thresholds for QIs in EUS (including 94.4% diagnostic rate of adequate samples and 83.8% diagnostic yield of malignancy in pancreatic masses) and ERCP (94.9% overall cannulation rate). In this prospective multicenter study, we found that although competence cannot be confirmed for all AETs at the end of training, most meet QI thresholds for EUS and ERCP at the end of their first year of independent practice. This finding affirms the effectiveness of training programs. Clinicaltrials.gov ID NCT02509416.

1 March 2018 in Clinical Gastroenterology and Hepatology
Verified
Journal Article
Closed access
SWSachin Wani
Sachin Wani
VMV. Raman Muthusamy
V. Raman Muthusamy
CMCindy M. McGrath
Cindy M. McGrath
ASAntonia R. Sepulveda
Antonia R. Sepulveda
ADAnanya Das
Ananya Das
JSJanak Shah
Janak Shah

30 April 2013 in Digestive Diseases and Sciences
Verified
Journal Article
Closed access
PDF file
SWSachin Wani
Sachin Wani
JAJulian Abrams
Julian Abrams
SESteven A. Edmundowicz
Steven A. Edmundowicz
SGSrinivas Gaddam
Srinivas Gaddam
CHChristine E. Hovis
Christine E. Hovis
PSPrateek Sharma
Prateek Sharma