2 August 2010 in Angewandte Chemie International Edition
12 January 2005 in Journal of Raman Spectroscopy
Raman spectra of fresh human lung tissues without any treatment such as freezing and/or formalin fixation were successfully recorded on a near‐infrared multichannel Raman system developed in our laboratory. It was confirmed that 1064 nm excitation was a requisite for the Raman study of fresh lung tissues; excitation at 785 nm failed to detect any Raman bands because of an extremely high fluorescence background. The observed Raman spectra of lung tissues made a clear distinction between the normal and cancerous states. We also succeeded in obtaining high signal‐to‐noise ratio Raman spectra of coagulated blood and carbon matter engulfed in the lung by scavenger cells. These results demonstrate the feasibility of 1064 nm near‐infrared multichannel Raman spectroscopy for in vivo, non‐invasive and molecular‐level clinical diagnosis of diseases including cancers. Copyright © 2005 John Wiley & Sons, Ltd.
28 June 2004 in Journal of Raman Spectroscopy
1 February 2019 in Heliyon
We study Raman spectra of ZnO nanoparticles of 5-12 nm size in the whole range of the first-order phonon bands. We apply the 3D phonon confinement model (PCM) for the interpretation of the observed Raman spectra. It is found that PCM is well applicable to the acoustic modes as well as to the optical ones, despite the fact that PCM has been thought not to be suitable for acoustic phonons. We show that the asymptotic behavior of PCM for the small-size limit is more consistent with the observation than that of the elastic sphere model (ESM). Furthermore, PCM gives detailed information on the complex size-dependent shapes of the phonon bands.
2 December 2010 in Optics Letters
We have developed a multifocus confocal Raman microspectroscopic system for the fast multimode vibrational imaging of living cells. It consists of an inverted microscope equipped with a microlens array, a pinhole array, a fiber bundle, and a multichannel Raman spectrometer. Forty-eight Raman spectra from 48 foci under the microscope are simultaneously obtained by using multifocus excitation and image-compression techniques. The multifocus confocal configuration suppresses the background generated from the cover glass and the cell culturing medium so that high-contrast images are obtainable with a short accumulation time. The system enables us to obtain multimode (10 different vibrational modes) vibrational images of living cells in tens of seconds with only laser power at one focal point. This image acquisition time is more than 10 times faster than that in conventional single-focus Raman microspectroscopy.
11 November 2011 in Journal of Biophotonics