Changes in thyroglobulin (Tg) and/or Tg antibody (TgAb) methods can disrupt the serial monitoring of differentiated thyroid carcinoma (DTC) patients. This study compared Tg measurements made in TgAb-negative and TgAb-positive sera using four RIA and 10 immunometric assay (IMA) methods. TgAb detection using a panel of 12 direct methods was contrasted with four Tg recovery tests. Sera from 110 normal euthyroid subjects (68 TgAb negative/42 TgAb positive) and 131 TgAb-negative DTC patients had Tg and/or TgAb analyses made by 10 laboratories in four countries. Euthyroid controls were used to compare Tg and TgAb ranges, sensitivities, and TgAb interference, whereas DTC patients were used to study Tg assay specificities, hook effects, and the influence of high Tg levels on TgAb measurements. Tg methods had high between-method variability [47 +/- 3% (+/-sem)] that was only marginally reduced by CRM-457 standardization (37 +/- 3%). All methods had suboptimal sensitivity, and some failed to detect Tg in some normal euthyroid controls. Although direct TgAb measurements were more reliable than exogenous recovery tests, TgAb status was only concordant in 65% of sera. Only four of 42 (9.5%) sera containing TgAb had antibody detected by all direct methods. All IMA methods reported paradoxically undetectable Tg for many TgAb-positive euthyroid controls, suggesting TgAb interference, whereas RIA methods reported appropriate normal range values for these same subjects. Some sera displaying interference had TgAb detected by only a minority of methods. Specificity differences, suboptimal sensitivity, hook effects, and an inability to reliably detect interfering TgAb compromise the clinical utility of current Tg and TgAb methods. All of the IMA methods were prone to underestimate serum Tg in the presence of TgAb, whereas the RIA methods appeared resistant to TgAb interference.
1 December 2011 in The Journal of Clinical Endocrinology & Metabolism
Thyroglobulin autoantibodies (TgAb) are primarily measured in serum in conjunction with thyroglobulin (Tg)--the primary tumor marker used to monitor patients with differentiated thyroid cancers (DTC). Every specimen needs TgAb testing to authenticate that the Tg measurement is not compromised by TgAb interference. When present, TgAb concentrations per se can be monitored as a surrogate tumor marker. The aims of the study were: 1) to review published reports concerning whether there are associations between DTC, thyroid autoimmunity (Hashimoto's thyroiditis), and the presence of TgAb; and 2) to evaluate the methodological factors that influence TgAb interference with serum Tg testing. PubMed was used to identify studies published over the last 55 yr that focused on DTC relationships with thyroid autoimmunity and the presence of thyroid autoantibodies. Many studies have reported significant associations between papillary thyroid cancer and Hashimoto's thyroiditis that may have a favorable prognostic significance. TgAb is detected in approximately 20% of DTC patients and may be a more specific thyroid tumor marker than thyroid peroxidase antibodies. TgAb interferes with Tg immunometric assay (IMA) measurements, causing falsely low/undetectable Tg values, especially when TgAb concentrations are high and serum Tg concentrations (measured by RIA) are low. TgAb concentrations respond to changes in Tg-secreting thyroid tissue such that the TgAb trend can be used as a more reliable surrogate DTC tumor marker than Tg IMA. Current TgAb assays may not always detect interfering TgAb because of insensitivity and specificity differences. It is critical to retain the same method for long-term TgAb monitoring. Patients with Hashimoto's thyroiditis frequently have TgAb detected and may have a higher risk for papillary thyroid cancer. Although TgAb interferes with Tg IMA measurements, TgAb trends can be used as a surrogate DTC tumor marker in preference to Tg IMA, provided that the same method is used.
1 November 2007 in The Journal of Clinical Endocrinology & Metabolism
Context: The setting of the TSH upper reference limit impacts the diagnosis of mild hypothyroidism and is currently controversial. Objective: Our objective was to evaluate factors influencing the TSH reference range. Design: Nonpregnant subjects aged 12 yr and older from National Health and Nutrition Examination Survey III were used to study the relationships between TSH, thyroid peroxidase antibodies (TPOAb), and thyroglobulin antibodies in different ethnic groups. Results: TPOAb prevalence was lowest (<3%) when TSH was between 0.1 and 1.5 mIU/liter in women and between 0.1 and 2.0 mIU/liter in men and progressively increased to above 50% when TSH exceeded 20 mIU/liter. TSH reference range parameters (2.5th, 50th, and 97.5th percentiles) were analyzed according to thyroid antibody status, race/ethnicity, and age for the 14,202 subjects made up of non-Hispanic Blacks (B), non-Hispanic whites (W), and Mexican-Americans (M) who did not report thyroid disease or taking thyroid-altering medications and whose total T4 was within the reference range. For each age group of each ethnicity, the inclusion of antibody-positive subjects increased TSH medians and upper limits (97.5th percentiles). The TSH upper limit was lower for the entire B cohort vs. W or M. However, this difference was lost when age cohorts with a similar prevalence of TPOAb (B age 40–49 yr vs. W and M age 20–29 yr) were compared. Conclusions: Ethnic differences in TSH were not present when populations with the same relative frequency of thyroid antibodies were compared. TSH upper reference limits may be skewed by TPOAb-negative individuals with occult autoimmune thyroid dysfunction.
1 October 2013 in Best Practice & Research Clinical Endocrinology & Metabolism
Thyroglobulin autoantibodies (TgAb) are detected at diagnosis or during treatment in approximately 25% of patients with differentiated thyroid cancer (DTC). When present, TgAb interferes with thyroglobulin (Tg) measurement causing falsely low or undetectable Tg immunometric assay (IMA) values that can mask disease. Guidelines mandate that every Tg test have TgAb measured simultaneously and quantitatively by immunoassay and not a recovery test. The propensity and magnitude of TgAb-Tg interference relates to both Tg and TgAb concentrations and the class of Tg method used. Because the TgAb trend reflects changes in thyroid tissue mass, TgAb concentrations serve as a surrogate post-operative DTC tumor marker. A rising, or de novo appearance of TgAb may indicate recurrence, whereas a progressive decline suggests successful treatment. This review focuses on the technical limitations of current TgAb methods, characteristics of TgAb interference with different classes of Tg method, and the clinical value of monitoring TgAb trends as a surrogate DTC tumor marker.
1 May 2011 in The Journal of Clinical Endocrinology & Metabolism
Specimens have thyroglobulin antibody (TgAb) measured prior to thyroglobulin (Tg) testing because the qualitative TgAb status (positive or negative) determines risk for Tg assay interference, and the quantitative TgAb concentration serves as a surrogate tumor marker for differentiated thyroid cancer. This study assessed the reliability of four TgAb methods to detect interfering TgAb [as judged from abnormally low Tg immunometric assay (IMA) to Tg RIA ratios] and determine whether between-method conversion factors might prevent a change in method from disrupting TgAb monitoring. Sera from selected and unselected TgAb-negative and TgAb-positive differentiated thyroid cancer patients had serum Tg measured by both IMA and RIA and TgAb measured by a reference method and three additional methods. The Tg IMA and Tg RIA values were concordant when TgAb was absent. Tg IMA to Tg RIA ratios below 75% were considered to indicate TgAb interference. Manufacturer-recommended cutoffs were set in the detectable range, and when used to determine the presence of TgAb misclassified many specimens displaying Tg interference as TgAb negative. False-negative misclassifications were virtually eliminated for two of four methods by using the analytical sensitivity (AS) as the detection limit for TgAb. Relationships between values for different specimens were too variable to establish between-method conversion factors. Many specimens with interfering TgAb were misclassified as TgAb negative using manufacturer-recommended cutoffs. It is recommended that assay AS limits be used to detect TgAb to minimize false-negative misclassifications. However, for two of four assays, AS limits failed to detect interfering TgAb in 20-30% of cases. TgAb methods were too qualitatively and quantitatively variable to establish conversion factors that would allow a change in method without disrupting serial TgAb monitoring.