Santica M. Marcovina

Santica M. Marcovina

Auto-generated profile, based on publicly available information

Santica M. Marcovina

Medpace Reference Laboratories, Cincinnati, OH

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2016 in Journal of Lipid Research
Verified
Journal Article
Open access
PDF file
SMSantica M. Marcovina
Santica M. Marcovina
JAJohn J. Albers
John J. Albers
The high degree of size heterogeneity of apolipoprotein(a) [apo(a)], the distinct protein component of lipoprotein(a) [Lp(a)], renders more difficult the development and selection of specific antibodies directed to apo(a) and poses significant challenges to the development of immunoassays to measure its concentration in plasma or serum samples. Apo(a) is extremely variable in size not only between but also within individuals because of the presence of two different, genetically determined apo(a) isoform sizes. Therefore, the antigenic determinants per particle available to interact with the antibodies will vary in the samples and the calibrators, thus contributing to apo(a) size-dependent inaccuracy of different methods. The lack of rigorous validation of the immunoassays and common means of expressing Lp(a) concentrations hinder the harmonization of results obtained by different studies and contribute to the lack of common cut points for identification of individuals at risk for coronary artery disease or for interventions aimed at reducing Lp(a) levels. The aim of our review is to present and critically evaluate the issues surrounding the measurements of Lp(a), their impact on the clinical interpretation of the data and the obstacles we need to overcome to achieve the standardization of Lp(a) measurements.

1 October 2013 in JACC
Verified
Journal Article
Closed access
JAJohn J. Albers
John J. Albers
ASApril Slee
April Slee
KOKevin Douglas O'Brien
Kevin Douglas O'Brien
JRJennifer G. Robinson
Jennifer G. Robinson
MKMoti L. Kashyap
Moti L. Kashyap
SMSantica M. Marcovina
Santica M. Marcovina

1 December 2000 in Clinical Chemistry
Verified
Journal Article
Open access
PDF file
SMSantica M Marcovina
Santica M Marcovina
JAJohn J Albers
John J Albers
ASAngelo M Scanu
Angelo M Scanu
HKHal Kennedy
Hal Kennedy
FGFederico Giaculli
Federico Giaculli
ASArmin Steinmetz
Armin Steinmetz
Background: As part of the NIH/National Heart, Lung and Blood Institute Contract for the Standardization of Lipoprotein(a) [Lp(a)] Measurements, a study was performed in collaboration with the IFCC Working Group for the Standardization of Lp(a) Assays. The aims of the study, performed with the participation of 16 manufacturers and 6 research laboratories, were to evaluate the IFCC proposed reference material (PRM) for its ability to transfer an accuracy-based value to the immunoassay calibrators and to assess concordance in results among different methods. Methods: Two different purified Lp(a) preparations with protein mass concentrations determined by amino acid analysis were used to calibrate the reference method. A Lp(a) value of 107 nmol/L was assigned to PRM. After uniformity of calibration was demonstrated in the 22 evaluated systems, Lp(a) was measured on 30 fresh-frozen sera covering a wide range of Lp(a) values and apolipoprotein(a) [apo(a)] sizes. Results: The among-laboratory CVs for these samples (6–31%) were, in general, higher than those obtained for PRM (2.8%) and the quality-control samples (14%, 12%, and 9%, respectively), reflecting the broad range of apo(a) sizes in the 30 samples and the sensitivity of most methods to apo(a) size heterogeneity. Thus, although all of the assays were uniformly calibrated through the use of PRM, no uniformity in results was achieved for the isoform-sensitive methods. Conclusions: Linear regression analyses indicated that to various degrees, apo(a) size heterogeneity affects the outcome of the immunochemical methods used to measure Lp(a). We have also shown that the inaccuracy of Lp(a) values determined by methods sensitive to apo(a) size significantly affects the assessment of individual risk status for coronary artery disease.

1 November 2003 in Clinical Chemistry
Verified
Journal Article
Open access
PDF file
SMSantica M. Marcovina
Santica M. Marcovina
MKMarlys L. Koschinsky
Marlys L. Koschinsky
JAJohn J. Albers
John J. Albers
SSSonia Skarlatos
Sonia Skarlatos
It has been estimated that ∼37% of the US population judged to be at high risk for developing coronary artery disease (CAD), based on the National Cholesterol Education Program guidelines, have increased plasma lipoprotein(a) [Lp(a)], whereas Lp(a) is increased in only 14% of those judged to be at low risk. Therefore, the importance of establishing a better understanding of the relative contribution of Lp(a) to the risk burden for CAD and other forms of vascular disease, as well as the underlying mechanisms, is clearly evident. However, the structural complexity and size heterogeneity of Lp(a) have hindered the development of immunoassays to accurately measure Lp(a) concentrations in plasma. The large intermethod variation in Lp(a) values has made it difficult to compare data from different clinical studies and to achieve a uniform interpretation of clinical data. A workshop was recently convened by the National Heart, Lung, and Blood Institute (NHLBI) to evaluate our current understanding of Lp(a) as a risk factor for atherosclerotic disorders; to determine how future studies could be designed to more clearly define the extent to which, and mechanisms by which, Lp(a) participates in these processes; and to present the results of the NHLBI-supported program for the evaluation and standardization of Lp(a) immunoassays. This report includes the most recent data presented by the workshop participants and the resulting practical and research recommendations.

1 February 2013 in Translational Research
Verified
Journal Article
Closed access
SMSantica M. Marcovina
Santica M. Marcovina
CSCesare Sirtori
Cesare Sirtori
APAndrea Peracino
Andrea Peracino
MGMihai Gheorghiade
Mihai Gheorghiade
PBPeggy Borum
Peggy Borum
HAHossein Ardehali
Hossein Ardehali

1 February 2021 in Journal of Clinical Investigation
Verified
Journal Article
Closed access
PDF file
RGRose A. Gubitosi-Klug
Rose A. Gubitosi-Klug
BBBarbara H. Braffett
Barbara H. Braffett
SHSusan Hitt
Susan Hitt
VAValerie Arends
Valerie Arends
DUDiane Uschner
Diane Uschner
JPJerry P. Palmer
Jerry P. Palmer
BACKGROUND. We investigated residual β cell function in Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) study participants with an average 35-year duration of type 1 diabetes mellitus (T1DM). METHODS. Serum C-peptide was measured during a 4-hour mixed-meal tolerance test. Associations with metabolic outcomes and complications were explored among nonresponders (all C-peptide values after meal 0.2), intermediate (>0.03 to ≤0.2), and low (≥ 0.003 to ≤0.03). RESULTS. Of the 944 participants, 117 (12.4%) were classified as responders. Residual C-peptide concentrations were associated with higher DCCT baseline concentrations of stimulated C-peptide (P value for trend = 0.0001). Residual C-peptide secretion was not associated with current or mean HbA1c, HLA high-risk haplotypes for T1DM, or the current presence of T1DM autoantibodies. The proportion of subjects with a history of severe hypoglycemia was lower with high (27%) and intermediate (48%) residual C-peptide concentrations than with low (74%) and no (70%) residual C-peptide concentrations (P value for trend = 0.0001). Responders and nonresponders demonstrated similar rates of advanced microvascular complications. CONCLUSION. β Cell function can persist in long-duration T1DM. With a peak C-peptide concentration of >0.03 nmol/L, we observed clinically meaningful reductions in the prevalence of severe hypoglycemia. TRIAL REGISTRATION. ClinicalTrials.gov NCT00360815 and NCT00360893. FUNDING. Division of Diabetes Endocrinology and Metabolic Diseases of the National Institute of Diabetes and Digestive and Kidney Diseases (DP3-DK104438, U01 DK094176, and U01 DK094157).