1 September 2001 in Tellus B: Chemical and Physical Meteorology
21 December 2012 in Atmospheric Chemistry and Physics
This study scrutinizes a decade-long series of ozone deposition measurements in a boreal forest in search for the signature and relevance of the different deposition processes. The canopy-level ozone flux measurements were analysed for deposition characteristics and partitioning into stomatal and non-stomatal fractions, with the main focus on growing season day-time data. Ten years of measurements enabled the analysis of ozone deposition variation at different time-scales, including daily to inter-annual variation as well as the dependence on environmental variables and concentration of biogenic volatile organic compounds (BVOC-s). Stomatal deposition was estimated by using multi-layer canopy dispersion and optimal stomatal control modelling from simultaneous carbon dioxide and water vapour flux measurements, non-stomatal was inferred as residual. Also, utilising the big-leaf assumption stomatal conductance was inferred from water vapour fluxes for dry canopy conditions. The total ozone deposition was highest during the peak growing season (4 mm s−1) and lowest during winter dormancy (1 mm s−1). During the course of the growing season the fraction of the non-stomatal deposition of ozone was determined to vary from 26 to 44% during day time, increasing from the start of the season until the end of the growing season. By using multi-variate analysis it was determined that day-time total ozone deposition was mainly driven by photosynthetic capacity of the canopy, vapour pressure deficit (VPD), photosynthetically active radiation and monoterpene concentration. The multi-variate linear model explained the high portion of ozone deposition variance on daily average level (R2 = 0.79). The explanatory power of the multi-variate model for ozone non-stomatal deposition was much lower (R2 = 0.38). The set of common environmental variables and terpene concentrations used in multivariate analysis were able to predict the observed average seasonal variation in total and non-stomatal deposition but failed to explain the inter-annual differences, suggesting that some still unknown mechanisms might be involved in determining the inter-annual variability. Model calculation was performed to evaluate the potential sink strength of the chemical reactions of ozone with sesquiterpenes in the canopy air space, which revealed that sesquiterpenes in typical amounts at the site were unlikely to cause significant ozone loss in canopy air space. The results clearly showed the importance of several non-stomatal removal mechanisms. Unknown chemical compounds or processes correlating with monoterpene concentrations, including potentially reactions at the surfaces, contribute to non-stomatal sink term.
21 October 2016 in Atmospheric Measurement Techniques
Large variability is inherent to turbulent flux observations. We review different methods used to estimate the flux random errors. Flux errors are calculated using measured turbulent and simulated artificial records. We recommend two flux errors with clear physical meaning: the flux error of the covariance, defining the error of the measured flux as 1 standard deviation of the random uncertainty of turbulent flux observed over an averaging period of typically 30 min to 1 h duration; and the error of the flux due to the instrumental noise. We suggest that the numerical approximation by Finkelstein and Sims (2001) is a robust and accurate method for calculation of the first error estimate. The method appeared insensitive to the integration period and the value 200 s sufficient to obtain the estimate without significant bias for variety of sites and wide range of observation conditions. The filtering method proposed by Salesky et al. (2012) is an alternative to the method by Finkelstein and Sims (2001) producing consistent, but somewhat lower, estimates. The method proposed by Wienhold et al. (1995) provides a good approximation to the total flux random uncertainty provided that independent cross-covariance values far from the maximum are used in estimation as suggested in this study. For the error due to instrumental noise the method by Lenschow et al. (2000) is useful in evaluation of the respective uncertainty. The method was found to be reliable for signal-to-noise ratio, defined by the ratio of the standard deviation of the signal to that of the noise in this study, less than three. Finally, the random uncertainty of the error estimates was determined to be in the order of 10 to 30 % for the total flux error, depending on the conditions and method of estimation.
23 March 2009 in Atmospheric Chemistry and Physics
Night-time ozone deposition for a Scots pine forest in Southern Finland was studied at the SMEAR II measurement station by evaluating the turbulent eddy covariance (EC), storage change and vertical advection fluxes. Similarly to night-time carbon dioxide flux, the eddy-covariance flux of ozone was decreasing with turbulence intensity (friction velocity), and storage change of the compound did not compensate the reduction (well-known night-time measurement problem). Accounting for vertical advection resulted in invariance of ozone deposition rate on turbulence intensity. This was also demonstrated for carbon dioxide, verified by independent measurements of NEE by chamber systems. The result highlights the importance of advection when considering the exchange measurements of any scalar. Analysis of aerodynamic and laminar boundary layer resistances by the model approach indicated that the surface resistance and/or chemical sink strength was limiting ozone deposition. The possible aerial ozone sink by known fast chemical reactions with sesquiterpenes and NO explain only a minor fraction of ozone sink. Thus the deposition is controlled either by stomatal uptake or surface reactions or both of them, the mechanisms not affected by turbulence intensity. Therefore invariance of deposition flux on turbulence intensity is expected also from resistance and chemical sink analysis.
22 January 2015 in Biogeosciences
Four gas analysers capable of measuring nitrous oxide (N2O) concentration at a response time necessary for eddy covariance flux measurements were operated from spring until winter 2011 over a field cultivated with reed canary grass (RCG, Phalaris arundinacea, L.), a perennial bioenergy crop in eastern Finland. The instruments were TGA100A (Campbell Scientific Inc.), CW-TILDAS-CS (Aerodyne Research Inc.), N2O / CO-23d (Los Gatos Research Inc.) and QC-TILDAS-76-CS (Aerodyne Research Inc.). The period with high emissions, lasting for about 2 weeks after fertilization in late May, was characterized by an up to 2 orders of magnitude higher emission, whereas during the rest of the campaign the N2O fluxes were small, from 0.01 to 1 nmol m−2 s−1. Two instruments, CW-TILDAS-CS and N2O / CO-23d, determined the N2O exchange with minor systematic difference throughout the campaign, when operated simultaneously. TGA100A produced the cumulatively highest N2O estimates (with 29% higher values during the period when all instruments were operational). QC-TILDAS-76-CS obtained 36% lower fluxes than CW-TILDAS-CS during the first period, including the emission episode, whereas the correspondence with other instruments during the rest of the campaign was good. The reasons for systematic differences were not identified, suggesting further need for detailed evaluation of instrument performance under field conditions with emphasis on stability, calibration and any other factors that can systematically affect the accuracy of flux measurements. The instrument CW-TILDAS-CS was characterized by the lowest noise level (with a standard deviation of around 0.12 ppb at 10 Hz sampling rate) as compared to N2O / CO-23d and QC-TILDAS-76-CS (around 0.50 ppb) and TGA100A (around 2 ppb). We identified that for all instruments except CW-TILDAS-CS the random error due to instrumental noise was an important source of uncertainty at the 30 min averaging level and the total stochastic error was frequently of the same magnitude as the fluxes when N2O exchange was small at the measurement site. Both instruments based on continuous-wave quantum cascade laser, CW-TILDAS-CS and N2O / CO-23d, were able to determine the same sample of low N2O fluxes with a high mutual coefficient of determination at the 30 min averaging level and with minor systematic difference over the observation period of several months. This enables us to conclude that the new-generation instrumentation is capable of measuring small N2O exchange with high precision and accuracy at sites with low fluxes.