Kaley A. Walker

Kaley A. Walker

Auto-generated profile, based on publicly available information

Kaley A. Walker

Department of Physics, University of Toronto, Toronto, Canada

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2017 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
WSWolfgang Steinbrecht
Wolfgang Steinbrecht
LFLucien Froidevaux
Lucien Froidevaux
RFRyan Fuller
Ryan Fuller
RWRay Wang
Ray Wang
JAJohn Anderson
John Anderson
FTFiona Tummon
Fiona Tummon
Ozone profile trends over the period 2000 to 2016 from several merged satellite ozone data sets and from ground-based data measured by four techniques at stations of the Network for the Detection of Atmospheric Composition Change indicate significant ozone increases in the upper stratosphere, between 35 and 48 km altitude (5 and 1 hPa). Near 2 hPa (42 km), ozone has been increasing by about 1.5 % per decade in the tropics (20° S to 20° N), and by 2 to 2.5 % per decade in the 35 to 60° latitude bands of both hemispheres. At levels below 35 km (5 hPa), 2000 to 2016 ozone trends are smaller and not statistically significant. The observed trend profiles are consistent with expectations from chemistry climate model simulations. This study confirms positive trends of upper stratospheric ozone already reported, e.g., in the WMO/UNEP Ozone Assessment 2014 or by Harris et al. (2015). Compared to those studies, three to four additional years of observations, updated and improved data sets with reduced drift, and the fact that nearly all individual data sets indicate ozone increase in the upper stratosphere, all give enhanced confidence. Uncertainties have been reduced, for example for the trend near 2 hPa in the 35 to 60° latitude bands from about ±5 % (2σ) in Harris et al. (2015) to less than ±2 % (2σ). Nevertheless, a thorough analysis of possible drifts and differences between various data sources is still required, as is a detailed attribution of the observed increases to declining ozone-depleting substances and to stratospheric cooling. Ongoing quality observations from multiple independent platforms are key for verifying that recovery of the ozone layer continues as expected.

7 September 2015 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
NHNeil R.P. Harris
Neil R.P. Harris
BHBirgit Hassler
Birgit Hassler
FTF. Tummon
F. Tummon
GBG. E. Bodeker
G. E. Bodeker
DHDaan Hubert
Daan Hubert
JZJ. M. Zawodny
J. M. Zawodny
Trends in the vertical distribution of ozone are reported and compared for a number of new and recently revised data sets. The amount of ozone-depleting compounds in the stratosphere (as measured by equivalent effective stratospheric chlorine – EESC) was maximised in the second half of the 1990s. We examine the periods before and after the peak to see if any change in trend is discernible in the ozone record that might be attributable to a change in the EESC trend, though no attribution is attempted. Prior to 1998, trends in the upper stratosphere (~ 45 km, 4 hPa) are found to be −5 to −10 % per decade at mid-latitudes and closer to −5 % per decade in the tropics. No trends are found in the mid-stratosphere (28 km, 30 hPa). Negative trends are seen in the lower stratosphere at mid-latitudes in both hemispheres and in the deep tropics. However, it is hard to be categorical about the trends in the lower stratosphere for three reasons: (i) there are fewer measurements, (ii) the data quality is poorer, and (iii) the measurements in the 1990s are perturbed by aerosols from the Mt Pinatubo eruption in 1991. These findings are similar to those reported previously even though the measurements for the main satellite and ground-based records have been revised. There is no sign of a continued negative trend in the upper stratosphere since 1998: instead there is a hint of an average positive trend of ~ 2 % per decade in mid-latitudes and ~ 3 % per decade in the tropics. The significance of these upward trends is investigated using different assumptions of the independence of the trend estimates found from different data sets. The averaged upward trends are significant if the trends derived from various data sets are assumed to be independent (as in Pawson et al., 2014) but are generally not significant if the trends are not independent. This occurs because many of the underlying measurement records are used in more than one merged data set. At this point it is not possible to say which assumption is best. Including an estimate of the drift of the overall ozone observing system decreases the significance of the trends. The significance will become clearer as (i) more years are added to the observational record, (ii) further improvements are made to the historic ozone record (e.g. through algorithm development), and (iii) the data merging techniques are refined, particularly through a more rigorous treatment of uncertainties.

8 June 2016 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
DHDaan Hubert
Daan Hubert
JLJean-Christopher Lambert
Jean-Christopher Lambert
TVTijl Verhoelst
Tijl Verhoelst
JGJosé Granville
José Granville
Arno KeppensArno Keppens
Arno Keppens
JZJoseph M. Zawodny
Joseph M. Zawodny
The ozone profile records of a large number of limb and occultation satellite instruments are widely used to address several key questions in ozone research. Further progress in some domains depends on a more detailed understanding of these data sets, especially of their long-term stability and their mutual consistency. To this end, we made a systematic assessment of 14 limb and occultation sounders that, together, provide more than three decades of global ozone profile measurements. In particular, we considered the latest operational Level-2 records by SAGE II, SAGE III, HALOE, UARS MLS, Aura MLS, POAM II, POAM III, OSIRIS, SMR, GOMOS, MIPAS, SCIAMACHY, ACE-FTS and MAESTRO. Central to our work is a consistent and robust analysis of the comparisons against the ground-based ozonesonde and stratospheric ozone lidar networks. It allowed us to investigate, from the troposphere up to the stratopause, the following main aspects of satellite data quality: long-term stability, overall bias and short-term variability, together with their dependence on geophysical parameters and profile representation. In addition, it permitted us to quantify the overall consistency between the ozone profilers. Generally, we found that between 20 and 40 km the satellite ozone measurement biases are smaller than ±5 %, the short-term variabilities are less than 5–12 % and the drifts are at most ±5 % decade−1 (or even ±3 % decade−1 for a few records). The agreement with ground-based data degrades somewhat towards the stratopause and especially towards the tropopause where natural variability and low ozone abundances impede a more precise analysis. In part of the stratosphere a few records deviate from the preceding general conclusions; we identified biases of 10 % and more (POAM II and SCIAMACHY), markedly higher single-profile variability (SMR and SCIAMACHY) and significant long-term drifts (SCIAMACHY, OSIRIS, HALOE and possibly GOMOS and SMR as well). Furthermore, we reflected on the repercussions of our findings for the construction, analysis and interpretation of merged data records. Most notably, the discrepancies between several recent ozone profile trend assessments can be mostly explained by instrumental drift. This clearly demonstrates the need for systematic comprehensive multi-instrument comparison analyses.

16 January 2009 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
EDE. Dupuy
E. Dupuy
KWK. A. Walker
K. A. Walker
JKJ. Kar
J. Kar
CBC. D. Boone
C. D. Boone
CMC. T. McElroy
C. T. McElroy
JZJ. M. Zawodny
J. M. Zawodny
This paper presents extensive {bias determination} analyses of ozone observations from the Atmospheric Chemistry Experiment (ACE) satellite instruments: the ACE Fourier Transform Spectrometer (ACE-FTS) and the Measurement of Aerosol Extinction in the Stratosphere and Troposphere Retrieved by Occultation (ACE-MAESTRO) instrument. Here we compare the latest ozone data products from ACE-FTS and ACE-MAESTRO with coincident observations from nearly 20 satellite-borne, airborne, balloon-borne and ground-based instruments, by analysing volume mixing ratio profiles and partial column densities. The ACE-FTS version 2.2 Ozone Update product reports more ozone than most correlative measurements from the upper troposphere to the lower mesosphere. At altitude levels from 16 to 44 km, the average values of the mean relative differences are nearly all within +1 to +8%. At higher altitudes (45–60 km), the ACE-FTS ozone amounts are significantly larger than those of the comparison instruments, with mean relative differences of up to +40% (about +20% on average). For the ACE-MAESTRO version 1.2 ozone data product, mean relative differences are within ±10% (average values within ±6%) between 18 and 40 km for both the sunrise and sunset measurements. At higher altitudes (~35–55 km), systematic biases of opposite sign are found between the ACE-MAESTRO sunrise and sunset observations. While ozone amounts derived from the ACE-MAESTRO sunrise occultation data are often smaller than the coincident observations (with mean relative differences down to −10%), the sunset occultation profiles for ACE-MAESTRO show results that are qualitatively similar to ACE-FTS, indicating a large positive bias (mean relative differences within +10 to +30%) in the 45–55 km altitude range. In contrast, there is no significant systematic difference in bias found for the ACE-FTS sunrise and sunset measurements.

12 February 2015 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
PSP. E. Sheese
P. E. Sheese
CBC. D. Boone
C. D. Boone
KWK. A. Walker
K. A. Walker
The ACE-FTS (Atmospheric Chemistry Experiment – Fourier Transform Spectrometer) instrument on board the Canadian satellite SCISAT has been observing the Earth's limb in solar occultation since its launch in 2003. Since February 2004, high resolution (0.02 cm−1) observations in the spectral region of 750–4400 cm−1 have been used to derive volume mixing ratio profiles of over 30 atmospheric trace species and over 20 atmospheric isotopologues. Although the full ACE-FTS level 2 data set is available to users in the general atmospheric community, until now no quality flags have been assigned to the data. This study describes the two-stage procedure for detecting physically unrealistic outliers within the data set for each retrieved species, which is a fixed procedure across all species. Since the distributions of ACE-FTS data across regions (altitude/latitude/season/local time) tend to be asymmetric and multimodal, the screening process does not make use of the median absolute deviation. It makes use of volume mixing ratio probability density functions, assuming that the data, when sufficiently binned, are at most tri-modal and that these modes can be represented by the superposition of three normal, or log-normal, distributions. Quality flags have been assigned to the data based on retrieval statistical fitting error, the physically unrealistic outliers described in this study, and known instrumental/processing errors. The quality flags defined and discussed in this study are now available for all level 2 versions 2.5 and 3.5 data and will be made available as a standard product for future versions.

7 June 2020 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
HWH. J. Ray Wang
H. J. Ray Wang
RDRobert Damadeo
Robert Damadeo
DFDavid Flittner
David Flittner
NKNatalya Kramarova
Natalya Kramarova
GTGhassan Taha
Ghassan Taha
EHEmrys Hall
Emrys Hall
The Stratospheric Aerosol and Gas Experiment III on the International Space Station (SAGE III/ISS) was launched on 19 February 2017 and began routine operation in June 2017. The first 2 years of SAGE III/ISS (v5.1) solar occultation ozone data were evaluated by using correlative satellite and ground‐based measurements. Among the three (MES, AO3, and MLR) SAGE III/ISS retrieved solar ozone products, AO3 ozone shows the smallest bias and best precision, with mean biases less than 5% for altitudes ~15–55 km in the midlatitudes and ~20–55 km in the tropics. In the lower stratosphere and upper troposphere, AO3 ozone shows high biases that increase with decreasing altitudes and reach ~10% near the tropopause. Preliminary studies indicate that those high biases primarily result from the contributions of the oxygen dimer (O4) not being appropriately removed within the ozone channel. The precision of AO3 ozone is estimated to be ~3% for altitudes between 20 and 40 km. It degrades to ~10–15% in the lower mesosphere (~55 km) and ~20–30% near the tropopause. There could be an altitude registration error of ~100 m in the SAGE III/ISS auxiliary temperature and pressure profiles. This, however, does not affect retrieved ozone profiles in native number density on geometric altitude coordinates. In the upper stratosphere and lower mesosphere (~40–55 km), the SAGE III/ISS (and SAGE II) retrieved ozone values show sunrise/sunset differences of ~5–8%, which are almost twice as large as what was observed by other satellites or model predictions. This feature needs further study.