18 April 2024 in International Sustainable Energy Conference - Proceedings
This study comprehensively examines the technical manifestation and planning process for a shared thermal energy network at a 75-hectare industrial area in Ingolstadt. Unlike traditional systems, this (5GDHC) network showcases a smart integration of energy flows across 70 buildings with a yearly heating demand of around 17 GWh and a yearly cooling demand of around 35 GWh. The network spans over 9,100 meters of piping with diameters up to 800 mm. With thermal power from various sources including 1.8 MW waste heat from a data centre and potential for 10 MW from the Danube River, the system epitomizes a dynamic balance of heating and cooling demands. The paper itself examines the planning process of the system and encompasses topics such as defining energy requirements and load profiles, assessing potential energy sources and sinks for enhanced system efficiency, and analysing pipe and network design. Through this investigation, the study provides valuable insights towards a methodology to facilitate the successful implementation of future industrial 5GDHC systems, furthering the cause of sustainable energy.
22 May 2026 in Renewable and Sustainable Energy Reviews
15 October 2026 in SSRN Electronic Journal
JPJazmine Johanni Binti Puriantoh
Jazmine Johanni Binti Puriantoh
Megawatt charging of heavy-duty trucks converts approximately 6% of transferred energy into heat. The cooling circuit collecting it runs at around 40 °C: too low for conventional district heating (DH) but well suited to low-temperature thermal source networks (TSN). The economic viability of recovering it has not yet been assessed. This study compares both pathways for a hub with ten charging points, an installed capacity of 10.7 MWel and 1,778 MWh a-1 of recoverable heat. The heat is either fed directly into a TSN or raised to 80 °C by a heat pump for a DH network. A discounted cash flow model yields levelized costs of heat for each pathway, measured against the alternative supply it would replace. Direct feed-in supplies at 1.4 ct kWh-1 against 7.9 ct kWh-1 via the heat pump. Furthermore, the direct pathway’s costs are 69% capital expenditure, incurred once, whereas the heat pump pathway’s costs are 69% recurring, primarily for compressor electricity. With reference tariffs of 3.5 and 8.5 ct kWh-1, direct feed-in provides a net present value of 430,000 € and repays in 4.2 years. The heat pump pathway returns 177,000 € but needs 13.7 years. Connection distance and hub size determine where this applies. Direct feed-in remains below its reference price at distances below 314 m, and below 569 m for sixteen megawatt charging points. Therefore, while waste heat recovery from megawatt charging hubs is economically promising, it depends on site selection. Furthermore, temperature upgrading broadens applicability, but reduces the economic benefits.
10 April 2026 in SSRN Electronic Journal
Thermal Source Networks (TSNs) are a key element of future district energy systems, because they enable the integration of locally available diverse renewable and waste-heat sources. Seasonal thermal energy storage (sTES) can enhance TSN flexibility by enabling inter-seasonal energy shifting and mitigating mismatches between supply and demand. This study investigates the optimal integration of a retrofit sTES into a TSN, using the incampus industrial park in Ingolstadt, Germany, as a case study. A dynamic simulation framework is developed by coupling a MATLAB/Simscape TSN model with a physics-based sTES model developed in Modelica/Dymola and exported as Functional Mock-up Unit. A parametric assessment is performed by varying key sTES design parameters (e.g., insulation) and demand characteristics (e.g., demand simultaneity). Performance is evaluated using three indicators: sTES efficiency, heating and cooling demand coverage, and levelized cost of thermal service (LCOTS). Results show that improved insulation and compact geometry increase storage efficiency by 21% and reduce LCOTS by 13%, whereas increasing sTES volume can increase LCOTS by 40%. A heat pump-assisted charging option extends the sTES usable temperature range and increases demand coverage by 16% without substantially increasing thermal losses. In contrast, higher demand simultaneity between heating and cooling reduces sTES utilization and leads to a pronounced increase in LCOTS by 125%. Overall, the analysis identifies a near-Pareto-optimal configuration that balances efficiency, coverage, and cost, and provides practical guidelines for integrating seasonal storage in next-generation low-temperature thermal networks.
18 April 2024 in International Sustainable Energy Conference - Proceedings
In the OREWA project, optimization measures for existing heat networks were identified and assessed based on both economic and ecological considerations [1]. One of the focal investigations was the simulation of intermittent operational strategies tailored for the summer months. Next to the classic intermittent approach an innovative variation was explored, which involved the storage of hot water during intermediate phases in large central tanks to further minimize heat losses. Both the classic and innovative intermittent strategies showcased substantial reductions in network losses and energy consumption for circulation pumps. This research shows the melioration of heat network efficiency through a substantial reduction of summer heat losses for a network with a low heat demand density of 0.7 MWh/(m²·a).