Bernard De Bruyne

Bernard De Bruyne

Auto-generated profile, based on publicly available information

Bernard De Bruyne

Department of Cardiology, Lausanne University Hospital (CHUV) , Rue du Bugnon 46, CH-1011 Lausanne

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2012 in New England Journal of Medicine
Verified
Journal Article
Closed access
PDF file
BBBernard De Bruyne
Bernard De Bruyne
NPNico H.J. Pijls
Nico H.J. Pijls
BKBindu Kalesan
Bindu Kalesan
EBEmanuele Barbato
Emanuele Barbato
PTPim A.L. Tonino
Pim A.L. Tonino
WFWilliam F. Fearon
William F. Fearon
The preferred initial treatment for patients with stable coronary artery disease is the best available medical therapy. We hypothesized that in patients with functionally significant stenoses, as determined by measurement of fractional flow reserve (FFR), percutaneous coronary intervention (PCI) plus the best available medical therapy would be superior to the best available medical therapy alone.

25 September 2014 in New England Journal of Medicine
Verified
Journal Article
Closed access
PDF file
BBBernard De Bruyne
Bernard De Bruyne
WFWilliam F. Fearon
William F. Fearon
NPNico H.J. Pijls
Nico H.J. Pijls
EBEmanuele Barbato
Emanuele Barbato
PTPim Tonino
Pim Tonino
PJPeter Jüni
Peter Jüni
We hypothesized that in patients with stable coronary artery disease and stenosis, percutaneous coronary intervention (PCI) performed on the basis of the fractional flow reserve (FFR) would be superior to medical therapy.

13 November 2001 in Circulation
Verified
Journal Article
Closed access
PDF file
BBBernard De Bruyne
Bernard De Bruyne
FHFerry Hersbach
Ferry Hersbach
NPNico H.J. Pijls
Nico H.J. Pijls
JBJozef Bartunek
Jozef Bartunek
JBJan-Willem Bech
Jan-Willem Bech
WWWilliam Wyns
William Wyns
Background Coronary arteries without focal stenosis at angiography are generally considered non–flow-limiting. However, atherosclerosis is a diffuse process that often remains invisible at angiography. Accordingly, we hypothesized that in patients with coronary artery disease, nonstenotic coronary arteries induce a decrease in pressure along their length due to diffuse coronary atherosclerosis. Methods and Results Coronary pressure and fractional flow reserve (FFR), as indices of coronary conductance, were obtained from 37 arteries in 10 individuals without atherosclerosis (group I) and from 106 nonstenotic arteries in 62 patients with arteriographic stenoses in another coronary artery (group II). In group I, the pressure gradient between aorta and distal coronary artery was minimal at rest (1±1 mm Hg) and during maximal hyperemia (3±3 mm Hg). Corresponding values were significantly larger in group II (5±4 mm Hg and 10±8 mm Hg, respectively; both P <0.001). The FFR was near unity (0.97±0.02; range, 0.92 to 1) in group I, indicating no resistance to flow in truly normal coronary arteries, but it was significantly lower (0.89±0.08; range, 0.69 to 1) in group II, indicating a higher resistance to flow. In 57% of arteries in group II, FFR was lower than the lowest value in group I. In 8% of arteries in group II, FFR was <0.75, the threshold for inducible ischemia. Conclusion Diffuse coronary atherosclerosis without focal stenosis at angiography causes a graded, continuous pressure fall along arterial length. This resistance to flow contributes to myocardial ischemia and has consequences for decision-making during percutaneous coronary interventions.

13 October 2009 in Circulation
Verified
Journal Article
Closed access
PDF file
MHMichalis Hamilos
Michalis Hamilos
OMOlivier Muller
Olivier Muller
TCThomas Cuisset
Thomas Cuisset
ANArgyrios Ntalianis
Argyrios Ntalianis
GCGregory Chlouverakis
Gregory Chlouverakis
BBBernard De Bruyne
Bernard De Bruyne
Background— Significant left main coronary artery stenosis is an accepted indication for surgical revascularization. The potential of angiography to evaluate the hemodynamic severity of a stenosis is limited. The aims of the present study were to assess the long-term clinical outcome of patients with an angiographically equivocal left main coronary artery stenosis in whom the revascularization strategy was based on fractional flow reserve (FFR) and to determine the relationship between quantitative coronary angiography and FFR. Methods and Results— In 213 patients with an angiographically equivocal left main coronary artery stenosis, FFR measurements and quantitative coronary angiography were performed. When FFR was ≥0.80, patients were treated medically or another stenosis was treated by coronary angioplasty (nonsurgical group; n=138). When FFR was <0.80, coronary artery bypass grafting was performed (surgical group; n=75). The 5-year survival estimates were 89.8% in the nonsurgical group and 85.4% in the surgical group ( P =0.48). The 5-year event-free survival estimates were 74.2% and 82.8% in the nonsurgical and surgical groups, respectively ( P =0.50). Percent diameter stenosis at quantitative coronary angiography correlated significantly with FFR ( r =−0.38, P <0.001), but a very large scatter was observed. In 23% of patients with a diameter stenosis <50%, the left main coronary artery stenosis was hemodynamically significant by FFR. Conclusions— In patients with equivocal stenosis of the left main coronary artery, angiography alone does not allow appropriate individual decision making about the need for revascularization and often underestimates the functional significance of the stenosis. The favorable outcome of an FFR-guided strategy suggests that FFR should be assessed in such patients before a decision is made “blindly” about the need for revascularization.

10 July 2001 in Circulation
Verified
Journal Article
Closed access
PDF file
BBBernard De Bruyne
Bernard De Bruyne
NPNico H.J. Pijls
Nico H.J. Pijls
JBJozef Bartunek
Jozef Bartunek
KKKemal Kulecki
Kemal Kulecki
JBJan-Willem Bech
Jan-Willem Bech
WWWilliam Wyns
William Wyns
Background — Fractional flow reserve (FFR), an index of coronary stenosis severity, can be calculated from the ratio of hyperemic distal to proximal coronary pressure. An FFR value of 0.75 can distinguish patients with normal and abnormal noninvasive stress testing in case of normal left ventricular function. The present study aimed at investigating the value of FFR in patients with a prior myocardial infarction. Methods and Results — In 57 patients who had sustained a myocardial infarction ≥6 days earlier, myocardial perfusion single photon emission scintigraphy (SPECT) imaging and FFR were obtained before and after angioplasty. The sensitivity and specificity of the 0.75 value of FFR to detect flow maldistribution at SPECT imaging were 82% and 87%. The concordance between the FFR and SPECT imaging was 85% ( P <0.001). When only truly positive and truly negative SPECT imaging were considered, the corresponding values were 87%, 100%, and 94% ( P <0.001). Patients with positive SPECT imaging before angioplasty had a significantly lower FFR than patients with negative SPECT imaging (0.52±0.18 versus 0.67±0.16, P =0.0079) but a significantly higher left ventricular ejection fraction (63±10% versus 52±10%, P =0.0009) despite a similar degree of diameter stenosis (67±13% versus 68±16%, P =NS). A significant inverse correlation was found between LVEF and FFR ( R =0.29, P =0.049). Conclusions — The present data indicate (1) that the 0.75 cutoff value of FFR to distinguish patients with positive from patients with negative SPECT imaging is valid after a myocardial infarction and (2) that for a similar degree of stenosis, the value of FFR depends on the mass of viable myocardium.

18 March 2014 in European Heart Journal
Verified
Journal Article
Open access
PDF file
Toth-Gayor GaborToth-Gayor Gabor
Toth-Gayor Gabor
MHMichalis Hamilos
Michalis Hamilos
SPStylianos Pyxaras
Stylianos Pyxaras
Fabio MangiacapraFabio Mangiacapra
Fabio Mangiacapra
ONOlivier Nelis
Olivier Nelis
BBBernard De Bruyne
Bernard De Bruyne
The present analysis addresses the potential clinical and physiologic significance of discordance in severity of coronary artery disease between the angiogram and fractional flow reserve (FFR) in a large and unselected patient population. Between September 1999 and December 2011, FFR and percent diameter stenosis (DS) as assessed by quantitative coronary angiography were obtained in 2986 patients (n = 4086 coronary stenoses), in whom at least one stenosis was of intermediate angiographic severity. Fractional flow reserve correlated slightly but significantly with DS [−0.38 (95% CI: −0.41; −0.36); P < 0.001]. The sensitivity, specificity, and diagnostic accuracy of a ≥50% DS for predicting FFR ≤ 0.80 were 61% (95% CI: 59; 63), 67% (95% CI: 65; 69), and 0.64 (95% CI: 0.56; 0.72), respectively. In different anatomical settings, sensitivity and specificity showed marked variations between 35 to 74% and 58 to 76%, respectively, resulting in a discordance in 35% of all cases for these thresholds. For an angiographic threshold of 70% DS, the diagnostic performance by the Youden's index decreased from 0.28 to 0.11 for the overall population. The data confirm that one-third of a large patient population shows discordance between angiogram ≥50%DS and FFR ≤0.8 thresholds of stenosis severity. Left main stenoses are often underestimated by the classical 50% DS cut-off compared with FFR. This discordance offers physiologic insights for future trials. It is hypothesized that the discordance between angiography and FFR is related to technical limitations, such as imprecise luminal border detection by angiography, as well as to physiologic factors, such as variable minimal microvascular resistance.