Tamer Turk

Tamer Turk

Auto-generated profile, based on publicly available information

Tamer Turk

Professor, Department of Orthodontics, Faculty of Dentistry, University of Ondokuz Mayis, Samsun, Turkey

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2009 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
YAYusuf Ata
Yusuf Ata
TTTamer Turk
Tamer Turk
MBMurat Bicer
Murat Bicer
MYMihriban Yalcin
Mihriban Yalcin
FAFiliz Ata
Filiz Ata
SYSenol Yavuz
Senol Yavuz
To describe aspects of the natural history and pathophysiology of coronary arteriovenous fistula and to propose potential treatment strategies. Eleven adult patients were treated surgically for coronary arteriovenous fistulas (8 male, 3 female) during the last three years. Mean age was 48,7 +/- 9,5 years (range 32-65 years). Diagnosis was made by coronary angiography and transesophageal echocardiography All patients were symptomatic due to the associating cardiac disorder or fistula. Presenting symptoms were chest pain, exertional dyspnea and palpitation. All patients were diagnosed by selective angiography. Transthoracic and transoesophageal echocardiography was performed to identify the Qp/Qs ratio in one patient. One patient who had an LAD to pulmonary artery coronary arteriovenous fistula with a vascular malformation needed early reoperation due to recurrence of the fistula. Echocardiographic evaluation at the postoperative third month revealed no residual shunts in all patients. Because of the severe complications that may develop due to coronary arteriovenous fistula, we believe that every coronary artery fistula should be treated invasively by surgery or transcatheter closure. But both treatment modalities still need to be evaluated with randomized multicenter studies for long term survival and effectiveness.

1 March 2008 in The Angle Orthodontist
Verified
Journal Article
Closed access
SESelma Elekdag-Turk
Selma Elekdag-Turk
TTTamer Turk
Tamer Turk
DIDevrim Isci
Devrim Isci
NONurhat Ozkalayci
Nurhat Ozkalayci
Objective: To determine the effects of thermocycling on shear bond strengths (SBSs) of a self-etching primer (SEP) after 0, 2000, and 5000 thermal cycles. Materials and Methods: Brackets were bonded to bovine incisors with two etching protocols. In the control group (conventional method) teeth were etched with 37% phosphoric acid. In the experimental group, an SEP (Transbond Plus) was applied as recommended by the manufacturer. Brackets were bonded with light-cure adhesive paste (Transbond XT) and light cured for 20 seconds in both groups. The SBSs were measured after water storage at 37°C for 24 hours, after 2000 and 5000 cycles of thermocycling between 5°C and 55°C. Bond failure location was determined with the Adhesive Remnant Index (ARI). Results: In the control group, SBSs did not show any significant differences among 0, 2000, and 5000 thermal cycles. However, in group SEP, SBSs decreased with 2000 and 5000 thermal cycles, and these decreases were significantly different from no thermocyling (P < .001). A significant difference was observed between ARI scores of the control group with 5000 thermal cycles and group SEP with no thermal cycles (P < .003). In addition, a significant difference was found between group SEP with no thermocycling and with 5000 thermal cycles (P < .003). Conclusion: The results of this study indicate that the SEP (Transbond Plus) provides clinically acceptable bond strength values compared with the conventional method after thermocycling.

1 January 2007 in The Angle Orthodontist
Verified
Journal Article
Closed access
TTTamer Turk
Tamer Turk
SESelma Elekdag-Turk
Selma Elekdag-Turk
DIDevrim Isci
Devrim Isci
Objective: To evaluate the effect of a self-etching primer on shear bond strengths (SBS) at the different debond times of 5, 15, 30, and 60 minutes and 24 hours. Materials and Methods: Brackets were bonded to human premolars with different etching protocols. In the control group (conventional method [CM]) teeth were etched with 37% phosphoric acid. In the study group, a self-etching primer (SEP; Transbond Plus Self Etching Primer; 3M Unitek, Monrovia, Calif) was applied as recommended by the manufacturer. Brackets were bonded with light-cure adhesive paste (Transbond XT; 3M Unitek) and light-cured for 20 seconds in both groups. The shear bond test was performed at the different debond times of 5, 15, 30 and 60 minutes and 24 hours. Results: Lowest SBS was attained with a debond time of 5 minutes for the CM group (9.51 MPa) and the SEP group (8.97 MPa). Highest SBS was obtained with a debond time of 24 hours for the CM group (16.82 MPa) and the SEP group (19.11 MPa). Statistically significant differences between the two groups were not observed for debond times of 5, 15, 30, or 60 minutes. However, the SBS values obtained at 24 hours were significantly different (P < .001). Conclusions: Adequate SBS was obtained with self-etching primer during the first 60 minutes (5, 15, 30 and 60 minutes) when compared with the conventional method. It is reliable to load the bracket 5 minutes after bonding using self-etching primer (Transbond Plus) with the light-cure adhesive (Transbond XT).

13 June 2006 in European Journal of Orthodontics
Verified
Journal Article
Closed access
PDF file
TTTamer Türk
Tamer Türk
DSDuygu Saraç
Duygu Saraç
YSY. Şinasi Saraç
Y. Şinasi Saraç
SESelma Elekdağ-Türk
Selma Elekdağ-Türk
The aim of this study was to determine the effectiveness of bonding brackets to ceramic restorations. Sixty feldspathic and 60 lithium disilicate ceramic specimens were randomly divided into six groups. Shear bond strength (SBS) and bond failure types were examined with six surface-conditioning methods: silane application to glazed surface, air particle abrasion (APA) with 25- and 50-μm aluminium trioxide (Al2O3), etching with 9.6 per cent hydrofluoric acid (HFA), and roughening with 40- and 63-μm diamond burs. Silane was applied to all roughened surfaces. Metal brackets were bonded with light cure composite, then stored in distilled water for 1 week and thermocycled (×500 at 5-55°C for 30 seconds). The ceramic surfaces were examined with a stereomicroscope at a magnification of ×10 to determine the amount of composite resin remaining using the adhesive remnant index. The lowest SBS values were obtained with HFA for feldspathic (5.39 MPa) and lithium disilicate (11.11 MPa) ceramics; these values were significantly different from those of the other groups. The highest SBS values were found with 63-μm diamond burs for feldspathic (26.38 MPa) and lithium disilicate (28.20 MPa) ceramics, and were not significantly different from 40-μm diamond burs for feldspathic and lithium disilicate ceramics (26.04 and 24.26 MPa, respectively). Roughening with 25- and 50-μm Al2O3 particles showed modest SBS for lithium disilicate (22.60 and 26.15 MPa, respectively) and for feldspathic ceramics (17.90 and 14.66 MPa, respectively). Adhesive failures between the ceramic and composite resin were noted in all groups. Damage to the porcelain surfaces was not observed. The SBS values were above the optimal range, except for feldspathic ceramic treated with HFA and silane. With all surface-conditioning methods, lithium disilicate ceramic displayed higher SBS than feldspathic ceramic.

21 January 2008 in European Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
SESelma Elekdag-Turk
Selma Elekdag-Turk
DIDevrim Isci
Devrim Isci
TTTamer Turk
Tamer Turk
FCFethiye Cakmak
Fethiye Cakmak
The aim of this study was to compare the clinical performance of a self-etching primer (SEP) with a conventional two-step etch and primer [conventional method (CM)]. The chair time required for bonding was also evaluated. Thirty-seven patients (14 males and 23 females) with a mean age of 16 years 5 months were included in the study. Six hundred and seventy-two brackets were bonded by one operator using a split-mouth design, with either SEP (Transbond Plus) or CM (Transbond XT). Bracket failure rates were estimated with respect to bonding procedure, dental arch, type of tooth (incisor, canine, and premolar), and gender. The results were evaluated using the chi-square test. The survival rate of the brackets was estimated with Kaplan–Meier analysis. Bracket survival distributions with respect to bonding procedure, dental arch, type of tooth, and patient gender were compared with a log-rank test. Bond failure interface was determined with the adhesive remnant index (ARI). The failure rates were 0.6 per cent for both bonding procedures. The failure and survival rates did not show significant differences between the bonding procedures, upper and lower dental arches, or gender. However, premolar brackets displayed a higher bond failure rate and a lower survival rate than incisor and canine brackets (P < 0.05). The mean bracket bonding time per tooth with SEP was significantly shorter than with CM (P < 0.001). No significant difference was observed for the ARI scores (P > 0.05). The results of this in vivo, randomized, cross-mouth clinical trial demonstrated a high survival rate with Transbond Plus. This finding indicates that SEP can be effectively used for bonding of orthodontic brackets.

1 November 2008 in The Angle Orthodontist
Verified
Journal Article
Closed access
SESelma Elekdag-Turk
Selma Elekdag-Turk
FCFethiye Cakmak
Fethiye Cakmak
DIDevrim Isci
Devrim Isci
TTTamer Turk
Tamer Turk
Objective: To compare the clinical performance of a self-etching primer (SEP) with a conventional two-step etch and primer method (CM). Materials and Methods: Study subjects were 39 patients with a mean age of 15 years 7 months. Six hundred and eighty-eight brackets were bonded by one operator with a split-mouth design, using Transbond Plus Self-Etching Primer or a conventional two-step etch and primer (Transbond XT). The survival rate of the brackets was estimated by the Kaplan-Meier analysis. Bracket survival distributions with respect to bonding procedure, dental arch, type of tooth (incisor, canine, and premolar) and patients' gender were compared using the log-rank test. Bond failure interface was determined using the Adhesive Remnant Index (ARI). Results: The bond failure rates of SEP and CM were 4.7% and 1.7%, respectively. A significant difference was found between the bonding procedures using the log-rank test (P < .05). Furthermore, canine and premolar teeth displayed a lower survival rate than incisor teeth (P < .05). Survival rates did not show significant differences between the upper and lower dental arches and patients' gender (P > .05). No significant difference was observed for ARI scores (P > .05). Conclusion: These findings indicate that the SEP (Transbond Plus) can be effectively used to bond orthodontic brackets.