Timothy M. Wright

Timothy M. Wright

Auto-generated profile, based on publicly available information

Timothy M. Wright

Hospital for Special Surgery, New York, NY

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2018 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
MPMichael Pitta
Michael Pitta
CEChristina I. Esposito
Christina I. Esposito
ZLZhichang Li
Zhichang Li
YLYuo-Yu Lee
Yuo-Yu Lee
TWTimothy M. Wright
Timothy M. Wright
DPDouglas E. Padgett
Douglas E. Padgett

22 February 2013 in Arthritis & Rheumatism
Verified
Journal Article
Open access
PDF file
FKFrank C. Ko
Frank C. Ko
CDCecilia Dragomir
Cecilia Dragomir
DPDarren A. Plumb
Darren A. Plumb
SGSteven R. Goldring
Steven R. Goldring
TWTimothy M. Wright
Timothy M. Wright
MMMarjolein C. H. van der Meulen
Marjolein C. H. van der Meulen
Objective: Alterations in the mechanical loading environment in joints may have both beneficial and detrimental effects on articular cartilage and subchondral bone, and may subsequently influence the development of osteoarthritis (OA). Using an in vivo tibial loading model, the aim of this study was to investigate the adaptive responses of cartilage and bone to mechanical loading and to assess the influence of load level and duration.Methods: Cyclic compression at peak loads of 4.5N and 9.0N was applied to the left tibial knee joint of adult (26‐week‐old) C57BL/6 male mice for 1, 2, and 6 weeks. Only 9.0N loading was utilized in young (10‐week‐old) mice. Changes in articular cartilage and subchondral bone were analyzed by histology and micro–computed tomography.Results: Mechanical loading promoted cartilage damage in both age groups of mice, and the severity of joint damage increased with longer duration of loading. Metaphyseal bone mass increased with loading in young mice, but not in adult mice, whereas epiphyseal cancellous bone mass decreased with loading in both young and adult mice. In both age groups, articular cartilage thickness decreased, and subchondral cortical bone thickness increased in the posterior tibial plateau. Mice in both age groups developed periarticular osteophytes at the tibial plateau in response to the 9.0N load, but no osteophyte formation occurred in adult mice subjected to 4.5N peak loading.Conclusion: This noninvasive loading model permits dissection of temporal and topographic changes in cartilage and bone and will enable investigation of the efficacy of treatment interventions targeting joint biomechanics or biologic events that promote OA onset and progression.

1 September 2011 in Bone
Verified
Journal Article
Closed access
MLMaureen E. Lynch
Maureen E. Lynch
RMRussell P. Main
Russell P. Main
QXQian Xu
Qian Xu
TSThomas L. Schmicker
Thomas L. Schmicker
MSMitchell B. Schaffler
Mitchell B. Schaffler
MMMarjolein C.H. van der Meulen
Marjolein C.H. van der Meulen

1 February 2016 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
GTGeorgios K. Triantafyllopoulos
Georgios K. Triantafyllopoulos
MEMarcella E. Elpers
Marcella E. Elpers
JBJayme C. Burket
Jayme C. Burket
CEChristina I. Esposito
Christina I. Esposito
DPDouglas E. Padgett
Douglas E. Padgett
TWTimothy M. Wright
Timothy M. Wright
And corrosion in large-diameter MoM THAs, but its impact on such damage in MoP THAs remains unknown. Questions/purposes (1) Is femoral head size associated with increased fretting or corrosion at the head-neck junction in MoP total hips? (2) Is duration of implantation associated with increased fretting or corrosion? Methods The severity of fretting/corrosion on surfaces of head tapers and stem trunnions was visually examined in 154 MoP THAs retrieved as part of 3282 revision surgeries performed at our institution between January 1, 2007, and December 31, 2013. Fretting and corrosion damage were subjectively graded by two independent observers on a 1 to 4 scale, and their relations to head size, alloy combinations, taper/trunnion design, length of implantation (LOI), and location were investigated. Differences in scores never exceeded one grade, and this occurred in only 17% of examined implants. With the available implants, the study provided 88% power to detect differences of 0.5 in fretting or corrosion scores in these analyses. Results Fretting and corrosion of the tapers and the trunnions were not affected by head size (p = 0.247, p = 0.471, p = 0.837, and p = 0.868, respectively), although taper/trunnion design affected taper fretting (p = 0.005) and corrosion (p = 0.0031) and trunnion fretting (p = 0.0028). Head taper fretting (observed in 73% of heads) increased with LOI, but head taper corrosion (noted in 93% of heads) was not affected. Trunnion fretting (observed in 86% of stems) was more severe in mixed-alloy combinations and with increased LOI and was more severe proximally. Trunnion corrosion (noted in 72% of stems) was also location-dependent with greater corrosion distally. Conclusions Fretting and corrosion are regular occurrences in MoP THAs, but neither damage type was related to femoral head size. Conversely, taper design, LOI, and alloy combination affected the severity of both fretting and corrosion. Clinical Relevance Although it has been suggested that trunnion corrosion seen in MoP bearings is a function of larger diameter heads, our data suggest that larger femoral heads may be used for increased damage at the modular junction of MoP THAs....

1 December 2017 in Osteoarthritis and Cartilage
Verified
Journal Article
Closed access
OAO.O. Adebayo
O.O. Adebayo
FKF.C. Ko
F.C. Ko
PWP.T. Wan
P.T. Wan
SGS.R. Goldring
S.R. Goldring
MGMary B Goldring
Mary B Goldring
MMM.C.H. van der Meulen
M.C.H. van der Meulen

1 January 2011 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Open access
PDF file
NKNatalie Kelly
Natalie Kelly
RFRose H. Fu
Rose H. Fu
TWTimothy M. Wright
Timothy M. Wright
DPDouglas E. Padgett
Douglas E. Padgett
Mobile-bearing TKAs reportedly have no clinical superiority over fixed-bearing TKAs, but a potential benefit is improved polyethylene wear behavior. We asked whether extent of damage and wear patterns would be less severe on retrieved mobile-bearing TKAs than on fixed-bearing TKAs and if correlations with patient demographics could explain differences in extent or locations of damage. We performed damage grading and mapping of 48 mobile-bearing TKAs retrieved due to osteolysis/loosening, infection, stiffness, instability or malpositioning. Visual grading used stereomicroscopy to identify damage, and a grade was assigned based on extent and severity. Each damage mode was then mapped onto a photograph of the implant surface, and the area affected was calculated. Marked wear damage occurred on both surfaces, with burnishing, scratching, and pitting the dominant modes. Damage occurred over a large portion of both surfaces, exceeding the available articular borders in nearly 30% of implants. Wear of mobile-bearing surfaces included marked third-body debris. Damage on tibiofemoral and mobile-bearing surfaces was not correlated with patient BMI or component alignment. Damage on mobile-bearing surfaces was positively correlated with length of implantation and was greater in implants removed for osteolysis or instability than in those removed for stiffness or infection. Each bearing surface in mobile-bearing implants was damaged to an extent similar to that in fixed-bearing implants, making the combined damage score higher than that for fixed-bearing implants. Mobile-bearing TKAs did not improve wear damage, providing another argument against the superiority of these implants over fixed-bearing implants.