Bryan A. Stenson

Bryan A. Stenson

Auto-generated profile, based on publicly available information

Bryan A. Stenson

Beth Israel Deaconess Medical Center, Department of Emergency Medicine, Boston, Massachusetts

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2024 in NEJM AI
Verified
Journal Article
Closed access
ABAkhil Bhargava
Akhil Bhargava
CLCarlos López-Espina
Carlos López-Espina
LSLee Schmalz
Lee Schmalz
SKShah Khan
Shah Khan
GWGregory L Watson
Gregory L Watson
NSNathan I. Shapiro
Nathan I. Shapiro

1 August 2020 in Emergency Medicine Clinics of North America
Verified
Journal Article
Closed access
BSBryan A. Stenson
Bryan A. Stenson
JAJared S. Anderson
Jared S. Anderson
SDSamuel R. Davis
Samuel R. Davis

1 March 2024
Verified
Journal Article
Open access
ADArjun Dhanik
Arjun Dhanik
BSBryan A. Stenson
Bryan A. Stenson
RLRobin B. Levenson
Robin B. Levenson
PAPeter S. Antkowiak
Peter S. Antkowiak
LSLeon D. Sanchez
Leon D. Sanchez
DCDavid T. Chiu
David T. Chiu
Introduction: A solution for emergency department (ED) congestion remains elusive. As reliance on imaging grows, computed tomography (CT) turnaround time has been identified as a major bottleneck. In this study we sought to identify factors associated with significantly delayed CT in the ED. Methods: We performed a retrospective analysis of all CT imaging completed at an urban, tertiary care ED from May 1-July 31, 2021. During that period, 5,685 CTs were performed on 4,344 patients, with a median time from CT order to completion of 108 minutes (Quartile 1 [Q1]: 57 minutes, Quartile 3 [Q3]: 182 minutes, interquartile range [IQR]: 125 minutes). Outliers were defined as studies that took longer than 369 minutes to complete (Q3 + 1.5 x IQR). We systematically reviewed outlier charts to determine factors associated with delay and identified five factors: behaviorally non -compliant or medically unstable patients; intravenous (IV) line issues; contrast allergies; glomerular filtration rate (GFR) concerns; and delays related to imaging protocol (eg, need for IV contrast, request for oral and/or rectal contrast). We calculated confidence intervals (CI) using the modified Wald method. Inter -rater reliability was assessed with a kappa analysis. Results: We identified a total of 182 outliers (4.2% of total patients). Fifteen (8.2%) cases were excluded for CT time -stamp inconsistencies. Of the 167 outliers analyzed, 38 delays (22.8%, 95% confidence interval [CI] 17.0-29.7) were due to behaviorally non -compliant or medically unstable patients; 30 (18.0%, 95% CI 12.8-24.5) were due to IV issues; 24 (14.4%, 95% CI 9.8-20.6) were due to contrast allergies; 21 (12.6%, 95% CI 8.3-18.5) were due to GFR concerns; and 20 (12.0%, 95% CI 7.8-17.9) were related to imaging study protocols. The cause of the delay was unknown in 55 cases (32.9%, 95% CI 26.3-40.4). Conclusion: Our review identified both modifiable and non -modifiable factors associated with significantly delayed CT in the ED. Patient factors such as behavior, allergies, and medical acuity cannot be controlled. However, institutional policies regarding difficult IV access, contrast administration in low GFR settings, and study protocols may be modified, capturing up to 42.6% of outliers. [West J Emerg Med. 2024;25(2)226-229.]

7 February 2023 in The American Journal of Emergency Medicine
Verified
Journal Article
Closed access
DCDavid T. Chiu
David T. Chiu
BSBryan A. Stenson
Bryan A. Stenson
MAMohammed Alghamdi
Mohammed Alghamdi
PAPeter S. Antkowiak
Peter S. Antkowiak
LSLeon D. Sanchez
Leon D. Sanchez

6 January 2026 in JAMIA Open
Verified
Journal Article
Open access
PDF file
GWGregory L Watson
Gregory L Watson
GSGrace Staples
Grace Staples
RCRobin Carver
Robin Carver
ABAkhil Bhargava
Akhil Bhargava
CLCarlos López-Espina
Carlos López-Espina
NSNathan I Shapiro
Nathan I Shapiro
Objectives: To assess the interpretability and acceptance of Shapley values for making artificial intelligence/machine learning (AI/ML) tools more transparent, interpretable, and useful to clinicians. Materials and Methods: Structured assessments were conducted with 30 clinicians (15 providers; 15 nurses; 8 assessments per clinician) to evaluate their ability to understand interventional Shapley Additive exPlanations (SHAP) values, a type of Shapley value that provides individualized variable importance scores and ascertain their perspective on SHAP value utility for the use of an AI/ML sepsis diagnostic. Participants were shown the diagnostic interface for real clinical scenarios with de-identified patient data with and without SHAP values. The primary outcomes were clinician ability to correctly interpret SHAP values and clinician self-reported improvement in their understanding of how the AI/ML algorithm produced its result. Results: Participants correctly interpreted SHAP values in 235 of 240 assessments (98%; CI, 95%-99%) and reported SHAP values improved their understanding of how the algorithm produced its result in every case (240/240; 100%; CI, 99%-100%). Participants were unanimous (30/30) in preferring the interface with SHAP values over the interface without. Discussion: Clinician participants strongly preferred the device interface with SHAP values, were unanimous in reporting SHAP values improved their understanding of the AI/ML diagnostic, and scored nearly perfectly when asked to interpret SHAP values. Conclusion: These results suggest health care providers value transparency into AI/ML algorithms designed for clinical use, and that Shapley values are a useful approach to providing that transparency, which in turn may improve tool adoption and clinical utility.

1 September 2021 in The Journal of Emergency Medicine
Verified
Journal Article
Open access
BSBryan A. Stenson
Bryan A. Stenson
JJJoshua W. Joseph
Joshua W. Joseph
PAPeter S. Antkowiak
Peter S. Antkowiak
DCDavid T. Chiu
David T. Chiu
LSLeon D. Sanchez
Leon D. Sanchez
Staffing and provider capacity are essential components of emergency department (ED) throughput. Patient flow is dependent on matching patient arrivals with provider capacity. Current models assume a static rate of patients per hour for providers; however, this metric has been shown to decrease throughout a shift in a pattern we describe as a staircase. We sought to analyze the demand capacity mismatch based on both a static and staircase model of resident productivity. We then suggest a new staggered staffing model that would improve flow in the ED. This was a retrospective analysis of patient demand and productivity, analyzing both static and staircase models of provider capacity. An alternative staggered shift model was then suggested, and a 2-sample t test was performed to assess if a new model reduces the amount of demand/capacity mismatch. Seventeen thousand five hundred twenty data points were analyzed over the 2-year interval, comparing the difference between actual patients placed into a treatment space at each hour and projected resident capacity based on the staircase model, using both the existing schedule and a new staggered schedule. Mean absolute values for the disparity in coverage was 2.69 (95% confidence interval 2.65-2.72) for the staircase scheduling model, and 2.14 (95% confidence interval 2.12-2.17) when staggering provider start times. The mean difference between these data sets was 0.54 (95% confidence interval 0.52-0.57; p < 0.0001). Academic EDs may find value in using a staircase model to analyze provider capacity because it is more reflective of actual capacity. EDs may benefit from visualizing their capacity curves to identify mismatches and staggering resident shifts to improve throughput and flow.