Ramón Ruiz-Mesa

Ramón Ruiz-Mesa

Auto-generated profile, based on publicly available information

Ramón Ruiz-Mesa

Oftalvist Jerez, Jerez de la Frontera, Spain

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2021 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Open access
CBChandra Bala
Chandra Bala
FPFrancisco Poyales
Francisco Poyales
MGMerce Guarro
Merce Guarro
RMRamón Ruiz Mesa
Ramón Ruiz Mesa
AMAli Mb Mearza
Ali Mb Mearza
JLJessie DrPH Lemp-Hull
Jessie DrPH Lemp-Hull
Purpose: To evaluate the effectiveness and safety of a new presbyopia-correcting intraocular lens (IOL) with a nondiffractive design, DFT015, compared with an aspheric monofocal IOL, SN60WF. Setting: 19 investigational sites in 4 countries: Australia, Canada, Spain, and the United Kingdom. Design: Prospective, randomized, parallel-group, controlled, assessor- and patient-masked clinical study. Methods: Participants aged ≥22 years with bilateral cataracts were randomized to DFT015 or SN60WF in a 5:4 ratio and masked until final postoperative follow-up at month 6. The primary effectiveness objective was superiority of DFT015 over SN60WF in mean monocular photopic distance-corrected intermediate visual acuity (DCIVA) at month 3. Secondary effectiveness objectives included noninferiority of DFT015 to SN60WF in mean monocular photopic corrected distance visual acuity (CDVA) and superiority in the mean monocular photopic distance-corrected near visual acuity (DCNVA) at month 3. Visual disturbances were assessed at month 6. Results: 282 patients were randomized to DFT015 (n = 159) or SN60WF (n = 123). All effectiveness objectives were achieved at month 3 in first eyes. For monocular photopic results in first eyes, DFT015 demonstrated superior mean DCIVA (least squares means of −0.139 logMAR in favor of DFT015, P < .001), noninferior mean CDVA (97.5% upper confidence limit [UCL] of the difference was <0.1 logMAR) and superior mean DCNVA (95% UCL of the difference was <0.0 logMAR) compared with SN60WF at month 6. DFT015 exhibited a similar visual disturbance profile to that of SN60WF. Conclusions: DFT015 provided superior intermediate and near vision and a similar visual disturbance profile compared with an aspheric monofocal IOL.

9 August 2017 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
RRRamón Ruiz-Mesa
Ramón Ruiz-Mesa
AAAntonio Abengózar-Vela
Antonio Abengózar-Vela
MRMaría Ruiz-Santos
María Ruiz-Santos
Purpose: To evaluate and compare the visual outcomes and ocular optical performance of the PanOptix trifocal intraocular lens (IOL) and Symfony extended range of vision IOL. Methods: Sixty-eight eyes of 34 patients were divided into 2 groups: 20 patients with the PanOptix IOL and 14 patients with the Symfony IOL. Binocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCDVA), distance-corrected intermediate visual acuity (DCIVA) at 80 and 60 cm, and distance-corrected near visual acuity (DCNVA) at 40 cm were evaluated. Additionally, preferred reading distance with best-corrected distance and visual acuity at that distance, binocular defocus curves, mesopic and photopic contrast sensitivity, photic phenomena, and monocular total higher order aberrations (HOAs) were also measured. Results: The visual outcomes for PanOptix and Symfony IOL groups, respectively, were as follows: BCDVA: -0.03 ± 0.03 and -0.02 ± 0.03 logMAR; DCIVA at 80 cm: 0.06 ± 0.06 and 0.06 ± 0.04 logMAR; DCIVA at 60 cm: 0.06 ± 0.10 and 0.05 ± 0.04 logMAR; DCNVA: 0.04 ± 0.06 and 0.20 ± 0.07 logMAR (p<0.001). Similar preferred reading distances were found for both groups (37.0 ± 4.6 and 38.9 ± 5.7 cm, respectively). The visual acuities at those distances were 0.09 ± 0.08 and 0.19 ± 0.08 logMAR (p<0.001), respectively. The defocus curves showed significantly better outcomes for the PanOptix IOL from -2.0 to -4.0 D (p<0.001). No significant differences were found for contrast sensitivity, halometry, or HOAs between the groups. Conclusions: The PanOptix and Symfony IOLs showed comparable visual performance at distance and intermediate. However, the PanOptix IOL provided better near and preferred reading distance VAs and showed a more continuous range of vision than the Symfony IOL.

28 January 2017 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
RRRamón Ruiz-Mesa
Ramón Ruiz-Mesa
AAAntonio Abengózar-Vela
Antonio Abengózar-Vela
AAAna Aramburu
Ana Aramburu
MRMaría Ruiz-Santos
María Ruiz-Santos
Purpose: To compare visual outcomes after cataract surgery with bilateral implantation of 2 intraocular lenses (IOLs): extended range of vision and trifocal. Methods: Each group of this prospective study comprised 40 eyes (20 patients). Phacoemulsification followed by bilateral implantation of a FineVision IOL (group 1) or a Symfony IOL (group 2) was performed. The following outcomes were assessed up to 1 year postoperatively: binocular uncorrected distance visual acuity (UDVA), binocular uncorrected intermediate visual acuity (UIVA) at 60 cm, binocular uncorrected near visual acuity (UNVA) at 40 cm, spherical equivalent (SE) refraction, defocus curves, mesopic and photopic contrast sensitivity, halometry, posterior capsule opacification (PCO), and responses to a patient questionnaire. Results: The mean binocular values in group 1 and group 2, respectively, were SE -0.15 ± 0.25 D and -0.19 ± 0.18 D; UDVA 0.01 ± 0.03 logMAR and 0.01 ± 0.02 logMAR; UIVA 0.11 ± 0.08 logMAR and 0.09 ± 0.08 logMAR; UNVA 0.06 ± 0.07 logMAR and 0.17 ± 0.06 logMAR. Difference in UNVA between IOLs (p<0.05) was statistically significant. There were no significant differences in contrast sensitivity, halometry, or PCO between groups. Defocus curves were similar between groups from 0 D to -2 D, but showed significant differences from -2.50 D to -4.00 D (p<0.05). Conclusions: Both IOLs provided excellent distance and intermediate visual outcomes. The FineVision IOL showed better near visual acuity. Predictability of the refractive results and optical performance were excellent; all patients achieved spectacle independence. The 2 IOLs gave similar and good contrast sensitivity in photopic and mesopic conditions and low perception of halos by patients.

1 November 2017 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
RRRamón Ruiz-Mesa
Ramón Ruiz-Mesa
AAAntonio Abengózar-Vela
Antonio Abengózar-Vela
MRMaría Ruiz-Santos
María Ruiz-Santos
To evaluate the repeatability of a new biometer using Scheimpflug technology combined with partial coherence interferometry (PCI) (Pentacam AXL) and its agreement with a device based on optical low-coherence reflectometry (OLCR), the Allegro Biograph. Oftalvist Centro Integral Ocular Jerez, Jerez de la Frontera, Spain. Evaluation of a diagnostic test. The mean keratometry (K), central corneal thickness (CCT), anterior chamber depth (ACD), and axial length (AL) were measured with the 2 devices 3 times by the same examiner in 2 groups (patients with cataract and patients without cataract). The repeatability was determined using the within-subject standard deviation, test-retest repeatability, coefficient of variation, and intraclass correlation coefficient. The correlation was evaluated with the Pearson coefficient and interchangeability with the Bland-Altman plot. Eighty eyes (40 eyes in each group) of 80 patients were analyzed. Significant differences were found between the Scheimpflug-PCI device and the OLCR device for mean K in the normal group (P < .001) and for CCT in the normal group (P < .05) and the cataract group (P < .001). There were no differences between devices in ACD and AL in either group. The repeatability between devices was similar. Although a significant correlation between devices was found for all measurements (all P < .001), wide limits of agreement were found in both groups for all biometric parameters. The Scheimpflug-PCI and OLCR devices showed excellent intravisit repeatability and high correlation for mean K, CCT, ACD, and AL in healthy and cataractous eyes. No differences were found in AL; however, the 2 devices might not be interchangeable.

2 January 2021 in International Ophthalmology
Verified
Journal Article
Closed access
PDF file
RRRamón Ruiz-Mesa
Ramón Ruiz-Mesa
JBJulia Blanch-Ruiz
Julia Blanch-Ruiz
MRMaría Ruiz-Santos
María Ruiz-Santos
RMRobert Montés-Micó
Robert Montés-Micó

18 June 2018 in Ophthalmology and Therapy
Verified
Journal Article
Open access
PDF file
RMRamón Ruiz Mesa
Ramón Ruiz Mesa
TMTiago Monteiro
Tiago Monteiro
Presbyopia is a condition that affects many as the lens ages, and is a secondary effect of cataract surgery. Multifocal lenses for the treatment of presbyopia have been undergoing cycles of development and improvement over the past two decades. The latest advancements have yielded lenses with a continuous range of optical powers, otherwise known as continuous transitional focus (CTF) lenses. Modern CTF lenses provide a more natural experience for patients while minimizing unwanted optical side effects.