Fahd Al-Sobayil

Fahd Al-Sobayil

Auto-generated profile, based on publicly available information

Fahd Al-Sobayil

Department of Veterinary Medicine, College of Agriculture and Veterinary Medicine, Qassim University, Qassim, Saudi Arabia

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2013 in Comparative Clinical Pathology
Verified
Journal Article
Closed access
PDF file
MTMohamed Thaarwat
Mohamed Thaarwat
AAAhmed Ali
Ahmed Ali
FAF. Al-Sobayil
F. Al-Sobayil

1 January 2007 in Journal of Veterinary Science
Verified
Journal Article
Open access
PDF file
FAFahd A. Al-Sobayil
Fahd A. Al-Sobayil
AAAhmed F. Ahmed
Ahmed F. Ahmed
Al-Sobayil FA, et al. J Vet Sci. 2007 Jun;8(2):185-191. http://dx.doi.org/10.4142/jvs.2007.8.2.185

3 August 2012 in BMC Veterinary Research
Verified
Journal Article
Open access
PDF file
MTMohamed Thaarwat
Mohamed Thaarwat
FAFahd Al-Sobayil
Fahd Al-Sobayil
AAAhmed Ali
Ahmed Ali
SBSebastien Buczinski
Sebastien Buczinski
Background: Echocardiography and intra-cardiac dimensions have not previously been reported in adult camels despite its potential application for medical purpose. The aim of this study was to describe the results of a prospective study, aiming to report normal cardiac appearance and normal chamber dimensions in adult camels (Camelus dromedarius).Results: On the right side, when the probe was placed in the 5thor 4thintercostal space (ICS), the caudal long-axis four-chamber view of the ventricles, atria, and the interventricular septum was obtained. Placing the probe slightly more cranially in the 4thICS, the caudal long-axis four-chamber view and the caudal long-axis view of the left ventricular outflow tract (LVOT) were imaged. In 7 camels, a hybrid view between a “four-chamber” and “LVOT view” was imaged from the same position. The short-axis view of the ventricles was obtained in the 4thICS where the transducer was rotated between 0° and 25°. Placement of the transducer in the 3rdICS allowed visualisation of the right ventricular outflow tract (RVOT). On the left side, when the probe was placed in the 5thor 4thICS, a four-chamber view was obtained. The LVOT is imaged in the 4thICS and the RVOT was seen from the 3rdICS.Conclusions: This study showed that it is possible to obtain good-quality echocardiograms in adult camels and provide normal cardiac dimensions. This study could be used as a reference for further studies concerning camels with cardiac diseases.

22 August 2017 in BMC Veterinary Research
Verified
Journal Article
Open access
PDF file
MTMohamed Thaarwat
Mohamed Thaarwat
FAFahd Al-Sobayil
Fahd Al-Sobayil
In goats, contagious caprine pleuropneumonia (CCPP) is a cause of major economic losses in Africa, Asia and in the Middle East. There is no information emphasising the importance of diagnostic ultrasound in goats with CCPP caused by Mycoplasma capricolum subsp. capripneumoniae (Mccp). This study was designed to describe the ultrasonographic findings in goats with CCPP caused by Mccp and to correlate ultrasonographic with post-mortem findings. To this end, 55 goats with CCPP were examined. Twenty-five healthy adult goats were used as a control group. Major clinical findings included harried, painful respiration, dyspnoea and mouth breathing. On ultrasonography, a liver-like echotexture was imaged in 13 goats. Upon post-mortem examination, all 13 goats exhibited unilateral pulmonary consolidation. Seven goats had a unilateral hypoechoic pleural effusion. At necropsy, the related lung was consolidated and the pleural fluid appeared turbid and greenish. Pleural abscessiation detected in five goats was confirmed post-mortem. Twenty-eight goats had a bright, fibrinous matrix extending over the chest wall containing numerous anechoic fluid pockets with medial displacement and compression of lung tissue. Echogenic tags imaged floating in the fluid were found upon post-mortem examination to be fibrin. In two goats, a consolidated right parenchyma was imaged together with hypoechoic pericardial effusions with echogenic tags covering the epicardium. At necropsy, the right lung was consolidated in three goats and fibrin threads were found covering the epicardium and pericardium. In goats with CCPP, the extension and the severity of the pulmonary changes could not be verified with clinical certainty in most cases, whereas this was possible most of the time with sonography, thus making the prognosis easier. Ultrasonographic examination of the pleurae and the lungs helped in the detection of various lesions.

1 July 2016 in Animal Reproduction Science
Verified
Journal Article
Closed access
AAAhmed Ali
Ahmed Ali
DDDerar R Derar
Derar R Derar
MTMohamed Thaarwat
Mohamed Thaarwat
MZMoustafa Zeitoun
Moustafa Zeitoun
FAFahd A. Alsobyil
Fahd A. Alsobyil

1 December 2010 in Research in Veterinary Science
Verified
Journal Article
Closed access
FAF.A. Al-Sobayil
F.A. Al-Sobayil