29 August 2014 in Optics Express
A new real-time laser differential confocal microscopy (RLDCM) without sample reflectivity difference effects is proposed for imaging height topography of sample surface, which divides the confocal microscopy imaging light path into two confocal microscopy imaging paths before and after focus with the equal axial detector offset oriented in opposite direction. By dividing the difference of the two signals simultaneously detected from these two confocal imaging paths by the higher signal between these two signals, RLDCM separates the signal that comes from reflectivity heterogeneity from the topographic signal in real time for the first time. RLDCM significantly reduces the height topography imaging time by single-layer scanning for the sample surface with reflectivity heterogeneity, and it achieves high axial resolution and lateral resolution similar to CM by optimizing the axial detector offset. Theoretical analysis and experimental results demonstrate that RLDCM realizes the real-time surface imaging for line structures featuring Silicon Dioxide steps on a Silicon base and achieves 2-nm axial depth resolution without reducing lateral resolution.
21 January 2010 in Optics Express
A new laser differential confocal radius measurement (DCRM) is proposed for high precision measurement of radius. Based on the property of an axial intensity curve that the absolute zero precisely corresponds to the focus of the objective in a differential confocal system (DCS), DCRM uses the zero point of the DCS axial intensity curve to precisely identify the cat's-eye and confocal positions of the test lens, and measures the accurate distance between the two positions to achieve the high-precision measurement of radius of curvature (ROC). In comparison with the existing measurement methods, DCRM proposed has a high measurement precision, a strong environmental anti-interference capability and a low cost. The theoretical analyses and preliminary experimental results indicate that DCRM has a relative measurement error of better than 5ppm.
29 May 2023 in Light: Science & Applications
Raman and Brillouin scattering are sensitive approaches to detect chemical composition and mechanical elasticity pathology of cells in cancer development and their medical treatment researches. The application is, however, suffering from the lack of ability to synchronously acquire the scattering signals following three-dimensional (3D) cell morphology with reasonable spatial resolution and signal-to-noise ratio. Herein, we propose a divided-aperture laser differential confocal 3D Geometry-Raman-Brillouin microscopic detection technology, by which reflection, Raman, and Brillouin scattering signals are simultaneously in situ collected in real time with an axial focusing accuracy up to 1 nm, in the height range of 200 μm. The divided aperture improves the anti-noise capability of the system, and the noise influence depth of Raman detection reduces by 35.4%, and the Brillouin extinction ratio increases by 22 dB. A high-precision multichannel microspectroscopic system containing these functions is developed, which is utilized to study gastric cancer tissue. As a result, a 25% reduction of collagen concentration, 42% increase of DNA substances, 17% and 9% decrease in viscosity and elasticity are finely resolved from the 3D mappings. These findings indicate that our system can be a powerful tool to study cancer development new therapies at the sub-cell level.
20 October 2009 in Optics Express
A new laser differential confocal focal-length measurement method is proposed for the measurement of an ultra-long focal-length. The approach proposed uses the property of an axial intensity curve that the absolute zero precisely corresponds to the focus of the objective in a differential confocal focusing system (DCFS) to measure the variation in position of DCFS focus with and without a measured ultra-long focal-length lens (UFL), uses the distance between the two focuses to obtain the UFL focal-length, and thereby achieving the precise measurement of ultra-long focal-length. The method has a high focusing precision, a strong anti-interference capability and a short measurement light-path. The theoretical analyses and preliminary experimental results indicate that the relative measurement error is about 0.01% when the method is used for the measurement of back-focus-distance (BFD).
22 September 2016 in Optics Express
Different measurement methods have been used to achieve different parameter measurements of a spherical lens, and multi-parameter measurements of a spherical lens have low measurement accuracy and efficiency. This paper proposes a new, laser differential confocal interference multi-parameter measurement (DCIMPM) method for spherical lens. Based on this proposed DCIMPM, a multi-parameter comprehensive measurement system is developed for spherical lens, which uses the laser differential confocal parameter measurement technique to measure the radius of curvature, thickness, and refractivity of spherical lens, and uses the laser interference measurement technique to measure the surface figure of a spherical lens. Therefore, the DCIMPM system, for the first time, achieves high-accuracy multi-parameter comprehensive measurements of a spherical lens on a single instrument. Experiments indicate that the developed DCIMPM system can achieve a measurement accuracy of 5 × 10−6 for the lens radius, 2.5 × 10−4 for the lens thickness, 2.2 × 10−4 for the lens refractivity, and a peak to valley of λ/20 for the surface figure of the lens. The proposed DCIMPM principle and developed system provide a new approach to achieve multi-parameter comprehensive measurements for spherical lens.
2 November 2012 in Optics Express
In this study, we found that the axial response curve of divided-aperture confocal microscopy has a shift while the point detector has a transverse offset from the optical axis. Based on this, a novel laser divided-aperture differential confocal sensing technology (LDDCST) with absolute zero and high axial resolution, as well as an LDDCST-based sensor, is proposed. LDDCST sets two micro-regions as virtual pinholes that are symmetrical to the optical axis along the xd direction on the focal plane of the divided-aperture confocal system to achieve the spot-division detection and to simplify the detection system, uses differential subtraction of two intensity responses simultaneously detected from the two micro-regions to achieve high axial resolution absolute measurement and low noise, and considers both resolution and measurement range by adjusting virtual pinholes in software. Theoretical analyses and packaged LDDCST sensor experiments indicate that LDDCST has high axial resolution as well as strong anti-interference and sectioning detection capability.