Hongshen Ma

Hongshen Ma

Auto-generated profile, based on publicly available information

Hongshen Ma

Department of Mechanical Engineering, University of British Columbia, 2054-6250 Applied Science Lane, Vancouver, BC, Canada V6T 1Z4

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2012 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SMSarah M. McFaul
Sarah M. McFaul
BLBill K. Lin
Bill K. Lin
HMHongshen Ma
Hongshen Ma
The separation of biological cells by filtration through microstructured constrictions is limited by unpredictable variations of the filter hydrodynamic resistance as cells accumulate in the microstructure. Applying a reverse flow to unclog the filter will undo the separation and reduce filter selectivity because of the reversibility of low-Reynolds number flow. We introduce a microfluidic structural ratchet mechanism to separate cells using oscillatory flow. Using model cells and microparticles, we confirmed the ability of this mechanism to sort and separate cells and particles based on size and deformability. We further demonstrate that the spatial distribution of cells after sorting is repeatable and that the separation process is irreversible. This mechanism can be applied generally to separate cells that differ based on size and deformability.

30 July 2013 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
CJChao Jin
Chao Jin
SMSarah M. McFaul
Sarah M. McFaul
SDSimon P. Duffy
Simon P. Duffy
XDXiaoyan Deng
Xiaoyan Deng
PTPeyman Tavassoli
Peyman Tavassoli
HMHongshen Ma
Hongshen Ma
Circulating tumor cells (CTCs) are malignant cells shed into the bloodstream from a tumor that have the potential to establish metastases in different anatomical sites. The separation and subsequent characterization of these cells is emerging as an important tool for both biomarker discovery and the elucidation of mechanisms of metastasis. Established methods for separating CTCs rely on biochemical markers of epithelial cells that are known to be unreliable because of epithelial-to-mesenchymal transition, which reduces expression for epithelial markers. Emerging label-free separation methods based on the biophysical and biomechanical properties of CTCs have the potential to address this key shortcoming and present greater flexibility in the subsequent characterization of these cells. In this review we first present what is known about the biophysical and biomechanical properties of CTCs from historical studies and recent research. We then review biophysical label-free technologies that have been developed for CTC separation, including techniques based on filtration, hydrodynamic chromatography, and dielectrophoresis. Finally, we evaluate these separation methods and discuss requirements for subsequent characterization of CTCs.

18 April 2012 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
QGQuan Guo
Quan Guo
SPSunyoung Park
Sunyoung Park
HMHongshen Ma
Hongshen Ma
We present a microfluidic technique for measuring the deformability of single cells using the pressure required to deform such cells through micrometre-scale tapered constrictions. Our technique is equivalent to whole-cell micropipette aspiration, but involves considerably simpler operation, less specialized equipment, and less technical skill. Single cells are infused into a microfluidic channel, and then deformed through a series of funnel-shaped constrictions. The constriction openings are sized to create a temporary seal with each cell as it passes through the constriction, replicating the interaction with the orifice of a micropipette. Precisely controlled deformation pressures are generated using an external source and then attenuated 100 : 1 using an on-chip microfluidic circuit. Our apparatus is capable of generating precisely controlled pressures as small as 0.3 Pa in a closed microchannel network, which is impervious to evaporative losses that normally limit the precision of such equipment. Intrinsic cell deformability, expressed as cortical tension, is determined from the threshold deformation pressure using the liquid-drop model. We measured the deformability of several types of nucleated cells and determined the optimal range of constriction openings. The cortical tension of passive human neutrophils was measured to be 37.0 ± 4.8 pN μm−1, which is consistent with previous micropipette aspiration studies. The cortical tensions of human lymphocytes, RT4 human bladder cancer cells, and L1210 mouse lymphoma cells were measured to be 74.7 ± 9.8, 185.4 ± 25.3, and 235.4 ± 31.0 pN μm−1 respectively. The precision and usability of our technique demonstrates its potential as a biomechanical assay for wide-spread use in biological and clinical laboratories.

24 February 2016 in Small
Verified
Journal Article
Closed access
PDF file
EPEmily S. Park
Emily S. Park
CJChao Jin
Chao Jin
QGQuan Guo
Quan Guo
RARichard R. Ang
Richard R. Ang
SDSimon P. Duffy
Simon P. Duffy
HMHongshen Ma
Hongshen Ma

8 January 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SPSunyoung Park
Sunyoung Park
RARichard R. Ang
Richard R. Ang
SDSimon P. Duffy
Simon P. Duffy
JBJenny Bazov
Jenny Bazov
KCKim N. Chi
Kim N. Chi
HMHongshen Ma
Hongshen Ma
Circulating tumor cell (CTC) enumeration promises to be an important predictor of clinical outcome for a range of cancers. Established CTC enumeration methods primarily rely on affinity capture of cell surface antigens, and have been criticized for underestimation of CTC numbers due to antigenic bias. Emerging CTC capture strategies typically distinguish these cells based on their assumed biomechanical characteristics, which are often validated using cultured cancer cells. In this study, we developed a software tool to investigate the morphological properties of CTCs from patients with castrate resistant prostate cancer and cultured prostate cancer cells in order to establish whether the latter is an appropriate model for the former. We isolated both CTCs and cultured cancer cells from whole blood using the CellSearch® system and examined various cytomorphological characteristics. In contrast with cultured cancer cells, CTCs enriched by CellSearch® system were found to have significantly smaller size, larger nuclear-cytoplasmic ratio, and more elongated shape. These CTCs were also found to exhibit significantly more variability than cultured cancer cells in nuclear-cytoplasmic ratio and shape profile.

1 June 2014 in Journal of Biomechanics
Verified
Journal Article
Closed access
QGQuan Guo
Quan Guo
SDSimon P. Duffy
Simon P. Duffy
KMKerryn Matthews
Kerryn Matthews
ASAline T. Santoso
Aline T. Santoso
MSMark D. Scott
Mark D. Scott
HMHongshen Ma
Hongshen Ma