Enteric viruses are important pathogens found in contaminated surface waters and have previously been detected in waters of the Great Lakes. Human adenoviruses were monitored because of their high prevalence and persistence in aquatic environments. In this study, we quantified adenoviruses in wastewater, surface water, and combined sewer overflows (CSOs) by real-time PCR. Between August 2005 and August 2006, adenovirus concentrations in raw sewage, primary-treated effluent, secondary-treated effluent, and chlorinated effluent from a wastewater treatment plant in Michigan were examined. CSO samples ( n = 6) were collected from a CSO retention basin in Grand Rapids, MI. Adenoviruses were detected in 100% of wastewater and CSO discharge samples. Average adenovirus DNA concentrations in sewage and CSOs were 1.15 × 10 6 viruses/liter and 5.35 × 10 5 viruses/liter, respectively. Adenovirus removal was <2 log 10 (99%) at the wastewater treatment plant. Adenovirus type 41 (60% of clones), type 12 (29%), type 40 (3%), type 2 (3%), and type 3 (3%) were isolated from raw sewage and primary effluents ( n = 28). Six of 20 surface water samples from recreational parks at the lower Grand River showed virus concentrations above the real-time PCR detection limit (average, 7.8 × 10 3 viruses/liter). This research demonstrates that wastewater effluents and wastewater-impacted surface waters in the lower Grand River in Michigan contain high levels of viruses and may not be suitable for full-body recreational activities. High concentrations of adenovirus in these waters may be due to inefficient removal during wastewater treatment and to the high persistence of these viruses in the environment.
Background: A groundwater-associated outbreak affected approximately 1,450 residents and visitors of South Bass Island, Ohio, between July and September 2004. Objectives: To examine the microbiological quality of groundwater wells located on South Bass Island, we sampled 16 wells that provide potable water to public water systems 15–21 September 2004. Methods: We tested groundwater wells for fecal indicators, enteric viruses and bacteria, and protozoa (Cryptosporidium and Giardia). The hydrodynamics of Lake Erie were examined to explore the possible surface water–groundwater interactions. Results: All wells were positive for both total coliform and Escherichia coli. Seven wells tested positive for enterococci and Arcobacter (an emerging bacterial pathogen), and F+-specific coliphage was present in four wells. Three wells were positive for all three bacterial indicators, coliphages, and Arcobacter; adenovirus DNA was recovered from two of these wells. We found a cluster of the most contaminated wells at the southeast side of the island. Conclusions: Massive groundwater contamination on the island was likely caused by transport of microbiological contaminants from wastewater treatment facilities and septic tanks to the lake and the subsurface, after extreme precipitation events in May–July 2004. This likely raised the water table, saturated the subsurface, and along with very strong Lake Erie currents on 24 July, forced a surge in water levels and rapid surface water–groundwater interchange throughout the island. Landsat images showed massive influx of organic material and turbidity surrounding the island before the peak of the outbreak. These combinations of factors and information can be used to examine vulnerabilities in other coastal systems. Both wastewater and drinking water issues are now being addressed by the Ohio Environmental Protection Agency and the Ohio Department of Health.
Group A rotaviruses (RV) are the major cause of acute gastroenteritis in infants and young children globally. Waterborne transmission of RV and the presence of RV in water sources are of major public health importance. In this paper, we present the Global Waterborne Pathogen model for RV (GloWPa-Rota model) to estimate the global distribution of RV emissions to surface water. To our knowledge, this is the first model to do so. We review the literature to estimate three RV specific variables for the model: incidence, excretion rate and removal during wastewater treatment. We estimate total global RV emissions to be 2 × 1018 viral particles/grid/year, of which 87% is produced by the urban population. Hotspot regions with high RV emissions are urban areas in densely populated parts of the world, such as Bangladesh and Nigeria, while low emissions are found in rural areas in North Russia and the Australian desert. Even for industrialized regions with high population density and without tertiary treatment, such as the UK, substantial emissions are estimated. Modeling exercises like the one presented in this paper provide unique opportunities to further study these emissions to surface water, their sources and scenarios for improved management.
1 September 2003 in Applied and Environmental Microbiology
This study evaluates the occurrence of Cryptosporidium oocysts and Giardia cysts in reclaimed effluents if method 1623 with the Envirochek capsule filters (standard and high-volume [HV] filters) and a modified version of the Information Collection Rule method (ICR) with the polypropylene yarn-wound cartridge filter are used. The recovery efficiency of the analytical methods was evaluated with samples of reagent, tap, and reclaimed water by using flow cytometer-sorted spike suspensions. (Oo)cyst recovery efficiency determined filter performance and method reproducibility in the water matrix tested. Method 1623 with the Envirochek HV capsule filter generated significantly higher recovery rates than did the standard Envirochek filter and the modified ICR method. Notwithstanding, large variations in recovery rates (>80%) occurred with samples of reclaimed water, and none of the water quality parameters analyzed in the reclaimed effluents could explain such variability. The highest concentrations of indigenous oocysts were detected by method 1623 with the HV filter, which provided a sufficient number of oocysts for further confirmation of infectious potential. Confirmation of species and potential infectivity for all positive protozoan samples was made by using a nested PCR restriction fragment polymorphism assay and the focus detection method most-probable-number assay, respectively. The methodology and results described in the present investigation provide useful information for the establishment of pathogen numeric standards for reclaimed effluents used for unrestricted irrigation.
Aims: To demonstrate the application of a new quantitative polymerase chain reaction (qPCR) technique for the determination of Helicobacter pylori concentrations in water, and to use this method to investigate the occurrence of the bacteria in sewage. The other aim was to study the survival capacity and detectability of the bacteria in artificially contaminated groundwater at different temperatures of 4 and 15°C. Methods and Results: The detection of H. pylori in water was aided by PCR using specific primers designed for the amplification of a fragment within the major vacuolating cytotoxin gene. Conventional culture was compared with conventional PCR and the new real-time (RT) qPCR approach for the quantification of the bacterium. Helicobacter pylori remained culturable for 120 h at 4°C as opposed to only 24 h at 15°C. RT qPCR demonstrated a 100-fold greater sensitivity for the detection of H. pylori DNA in comparison with conventional PCR. Scanning electron microscopic (SEM) observation showed that the normal spiral form changed to a coccoid form after 24 and 72 h at 15 and 4°C, respectively. Helicobacter pylori was found at 2–28 cells ml−1 in sewage, of the 23 sewage samples – 84% were positive for H. pylori species-specific vacuolating cyctotoxin gene (vacA) by RT qPCR, but were negative by conventional PCR. Conclusions: The RT qPCR assay provided a specific, sensitive and rapid method for the quantitative detection of H. pylori in sewage. This molecular method would be valuable in studying the prevalence of H. pylori as required by the United States Environmental Protection Agency Contaminant Candidate List, particularly in nondisinfected ground waters, in sewage as a source of contamination, and for addressing the possible presence of viable but nonculturable of H. pylori. Significance and Impact of the Study: The quantitative detection of H. pylori by rapid and less-expensive methods than the TaqMan Assay using SYBR green could be an important tool to monitor infection in community by measuring the concentrations in sewage and to meet the new regulatory and risk-based frameworks for water supplies.
This study investigated the use of iron and aluminum and their combinations as electrodes to determine the technically sound and economically feasible electrochemical approach for the treatment of anaerobic digestion effluent. The results indicated that the use of iron as anode and cathode is the most suitable solution among different electrode combinations. The reduction of turbidity, total chemical oxygen demand, total phosphorus, total coliforms, Escherichia coli, Enterococci, and phages in the reclaimed water were 99%, 91%, 100%, 1.5 log, 1.7 log, 1.0 log, and 2.0 log, respectively. The economic assessment further concluded that the average treatment cost is $3 per 1000 L for a small-scale operation handling 3000 L wastewater/day. This study demonstrated that the electrocoagulation (EC) is a promising technique for the recovery and reclamation of water from anaerobic digestion effluent. Even though its energy consumption is higher and the nitrogen removal is insufficient compared to some conventional wastewater treatment technologies, there are several advantages of the EC treatment, such as short retention time, small footprint, no mixing, and gradual addition of coagulants. These features make EC technology applicable to be used alone or combined with other technologies for a wide range of wastewater treatment applications.