Intra-aortic balloon pumps (IABPs) have been the mainstay of mechanical circulatory support (MCS) for patients with cardiogenic shock in the setting of acute myocardial infarction (AMI).
1 However, randomized clinical trial (RCT) data
2,3 and subsequent meta-analyses
4,5 have reported no clinical benefit from routine IABP use in patients with AMI complicated by cardiogenic shock. Impella devices (intravascular microaxial left ventricular assist devices [LVADs]), which offer greater improvement in hemodynamic parameters compared with IABPs,
6 received US marketing clearance in 2008 for providing partial circulatory support for up to 6 hours using an extracorporeal bypass control unit and providing circulatory support during procedures not requiring cardiopulmonary bypass.
7 Studies through 2012 showed a substantial uptake of these devices, from 4.6 per million hospital discharges in 2007 to 138 per million discharges in 2012,
8,9 despite the absence of demonstrated benefits for hard clinical end points in RCTs.
6,10 National Cardiovascular Data Registry (NCDR) records through September 2013 showed that use of MCS devices other than IABP was clustered around a relatively small number of hospitals but did not increase.
9