Charles B. Yeamans

Charles B. Yeamans

Auto-generated profile, based on publicly available information

Charles B. Yeamans

Lawrence Livermore National Laboratory, Livermore, CA, United States of America

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2017 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
LDL. Divol
L. Divol
APA. Pak
A. Pak
LHL. F. Berzak Hopkins
L. F. Berzak Hopkins
SPS. Le Pape
S. Le Pape
NMN. B. Meezan
N. B. Meezan
MEM. J. Edwards
M. J. Edwards
We report on the most recent and successful effort at controlling the trajectory and symmetry of a high density carbon implosion at the National Ignition Facility. We use a low gasfill (0.3 mg/cc He) bare depleted uranium hohlraum with around 1 MJ of laser energy to drive a 3-shock-ignition relevant implosion. We assess drive performance and we demonstrate symmetry control at convergence 1, 3–5, 12, and 27 to better than ±5 μm using a succession of experimental platforms. The symmetry control was maintained at a peak fuel velocity of 380 km/s. Overall, implosion symmetry measurements are consistent with the pole-equator symmetry of the X-ray drive on the capsule being better than 5% in the foot of the drive (when shocks are launched) and better than 1% during peak drive (main acceleration phase). This level of residual asymmetry should have little impact on implosion performance.

30 March 2018 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
DCD. T. Casey
D. T. Casey
CTC. A. Thomas
C. A. Thomas
KBK. L. Baker
K. L. Baker
BSB. K. Spears
B. K. Spears
MHM. Hohenberger
M. Hohenberger
CWC. Wild
C. Wild
The Bigfoot approach is to intentionally trade off high convergence, and therefore areal-density, in favor of high implosion velocity and good coupling between the laser, hohlraum, shell, and hotspot. This results in a short laser pulse that improves hohlraum symmetry and predictability, while the reduced compression reduces hydrodynamic instability growth. The results thus far include demonstrated low-mode symmetry control at two different hohlraum geometries (5.75 mm and 5.4 mm diameters) and at two different target scales (5.4 mm and 6.0 mm hohlraum diameters) spanning 300–405 TW in laser power and 0.8–1.6 MJ in laser energy. Additionally, by carefully scaling the 5.4 mm design to 6.0 mm, an increase in target scale of 13%, equivalent to 40% increase in laser energy, has been demonstrated.

1 May 2017 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
TMT. Ma
T. Ma
PPP. K. Patel
P. K. Patel
NIN. Izumi
N. Izumi
PSP. T. Springer
P. T. Springer
MKM. H. Key
M. H. Key
MEM. J. Edwards
M. J. Edwards
Hydrodynamic mix of the ablator into the DT fuel layer and hot spot can be a critical performance limitation in inertial confinement fusion implosions. This mix results in increased radiation loss, cooling of the hot spot, and reduced neutron yield. To quantify the level of mix, we have developed a simple model that infers the level of contamination using the ratio of the measured x-ray emission to the neutron yield. The principal source for the performance limitation of the “low-foot” class of implosions appears to have been mix. Lower convergence “high-foot” implosions are found to be less susceptible to mix, allowing velocities of >380 km/s to be achieved.

1 May 2016 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
SPS. Le Pape
S. Le Pape
LHL. F. Berzak Hopkins
L. F. Berzak Hopkins
LDL. Divol
L. Divol
NMN. Meezan
N. Meezan
DTD. Turnbull
D. Turnbull
MEM. J. Edwards
M. J. Edwards
The near vacuum campaign on the National Ignition Facility has concentrated its efforts over the last year on finding the optimum target geometry to drive a symmetric implosion at high convergence ratio (30×). As the hohlraum walls are not tamped with gas, the hohlraum is filling with gold plasma and the challenge resides in depositing enough energy in the hohlraum before it fills up. Hohlraum filling is believed to cause symmetry swings late in the pulse that are detrimental to the symmetry of the hot spot at high convergence. This paper describes a series of experiments carried out to examine the effect of increasing the distance between the hohlraum wall and the capsule (case to capsule ratio) on the symmetry of the hot spot. These experiments have shown that smaller Case to Capsule Ratio (CCR of 2.87 and 3.1) resulted in oblate implosions that could not be tuned round. Larger CCR (3.4) led to a prolate implosion at convergence 30× implying that inner beam propagation at large CCR is not impeded by the expanding hohlraum plasma. A Case to Capsule ratio of 3.4 is a promising geometry to design a round implosion but in a smaller hohlraum where the hohlraum losses are lower, enabling a wider cone fraction range to adjust symmetry.

1 April 2016 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
HRH. F. Robey
H. F. Robey
VSV. A. Smalyuk
V. A. Smalyuk
JMJ. L. Milovich
J. L. Milovich
TDT. Döppner
T. Döppner
DCD. T. Casey
D. T. Casey
MJM. Gatu Johnson
M. Gatu Johnson
A series of indirectly driven capsule implosions has been performed on the National Ignition Facility to assess the relative contributions of ablation-front instability growth vs. fuel compression on implosion performance. Laser pulse shapes for both low and high-foot pulses were modified to vary ablation-front growth and fuel adiabat, separately and controllably. Three principal conclusions are drawn from this study: (1) It is shown that reducing ablation-front instability growth in low-foot implosions results in a substantial (3-10X) increase in neutron yield with no loss of fuel compression. (2) It is shown that reducing the fuel adiabat in high-foot implosions results in a significant (36%) increase in fuel compression together with a small (10%) increase in neutron yield. (3) Increased electron preheat at higher laser power in high-foot implosions, however, appears to offset the gain in compression achieved by adiabat-shaping at lower power. These results taken collectively bridge the space between the higher compression low-foot results and the higher yield high-foot results.

24 May 2017 in Fusion Science and Technology
Verified
Journal Article
Closed access
CYC. B. Yeamans
C. B. Yeamans
DBD. L. Bleuel
D. L. Bleuel
In need of a spatially resolved neutronic measurement to better understand the implosion physics of inertial-confined fusion, the National Ignition Facility (NIF) developed a distributed Flange-mounted Neutron Activation Diagnostic system (FNAD). FNAD measures primary deuterium-tritium (D-T) fusion neutron fluence at 20 points surrounding the target chamber using the 90Zr(n,2n)89Zr reaction, utilizing the 12.1-MeV reaction threshold to minimize signal from spurious neutron sources. Through careful design of the measurement systematics, the relative ratios of fluence at those 20 points are measured to within 2%. This precision is sufficient to allow interpretation of the resulting neutron sky as a map of scattering mass areal density (ρR) of the cold compressed D-T fuel surrounding the nuclear burn. Controlling the shape of this fuel during assembly is essential to achieving optimal implosion performance. This paper details the system design and locational deployment, measurement techniques, and calibration procedure. It also outlines data analysis and reduction, and data presentation methods used during the National Ignition Campaign and High-Foot Campaign.