A Li

Dr. A Li

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2018 in Bioinspiration & Biomimetics
Verified
Journal Article
Closed access
PDF file
NLNing Li
Ning Li
TYTie Yang
Tie Yang
PYPeng Yu
Peng Yu
JCJunling Chang
Junling Chang
LZLiang Zhao
Liang Zhao
LLLianqing Liu
Lianqing Liu
Stroke has become the leading cause of disability and the second-leading cause of mortality worldwide. Dyskinesia complications are the major reason of these high death and disability rates. As a tool for rapid motion function recovery in stroke patients, exoskeleton robots can reduce complications and thereby decrease stroke mortality rates. However, existing exoskeleton robots interfere with the wearer's natural motion and damage joints and muscles due to poor human-machine coupling. In this paper, a novel ergonomic soft bionic exoskeleton robot with 7 degrees of freedom was proposed to address these problems based on the principles of functional anatomy and sports biomechanics. First, the human motion system was analysed according to the functional anatomy, and the muscles were modelled as tension lines. Second, a soft bionic robot was established based on the musculoskeletal tension line model. Third, a robot control method mimicking human muscle control principles was proposed and optimized on a humanoid platform manufactured using 3D printing. After the control method was optimized, the motion trajectory similarities between humans and the platform exceeded 87%. Fourth, the force-assisted effect was tested based on electromyogram signals, and the results showed that muscle signals decreased by 58.17% after robot assistance. Finally, motion-assistance experiments were performed with stroke patients. The joint movement level increased by 174% with assistance, which allowed patients to engage in activities of daily living. With this robot, stroke patients could recover their motion functions, preventing complications and decreasing fatality and disability rates.

1 March 2022 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
WCWenyuan Chen
Wenyuan Chen
GLGuangyong Li
Guangyong Li
NLNing Li
Ning Li
WWWenxue Wang
Wenxue Wang
PYPeng Yu
Peng Yu
Lianqing LiuLianqing Liu
Lianqing Liu
It has been clinically proven that exoskeletons are effective self-training rehabilitation or daily living assistance devices for patients with hand dysfunctions. However, exoskeleton-assisted hand exercises with high degrees-of-freedom are considered as challenging tasks because the digit space, especially the thumb, cannot accommodate enough actuators. In this article, we report a tendon-driven soft hand exoskeleton with a hybrid configuration for thumb actuation. The soft hand exoskeleton system uses the least number of actuators to realize full degrees-of-freedom actuation for all digits. It is tested on a stroke patient with hemiplegia and a healthy subject. The experimental results show that the hand exoskeleton could assist the stroke patient to accomplish various training tasks, such as thumb encircling, grasping, pinching, releasing, and writing. It was found that digit trajectories and joint angle changes of the stroke patient were close to those of the healthy subject. Especially, the range of motion of the stroke patient shows significant improvement with the hand exoskeleton assistance compared to that without the hand exoskeleton assistance. The research in this article paves the way to develop fully actuated soft hand exoskeleton that can be eventually integrated with an electroencephalogram or electromyography for self-training rehabilitation or daily living assistance.

8 December 2022 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
NLNing Li
Ning Li
YYYang Yang
Yang Yang
GLGang Li
Gang Li
TYTie Yang
Tie Yang
YWYihan Wang
Yihan Wang
Lianqing LiuLianqing Liu
Lianqing Liu
Assist-as-needed (AAN) assistance can promote active voluntary participation in rehabilitation and motor function recovery of post-stroke patients. However, different patients have personalized damaged regions and recovery states, causing difficulties to obtain adaptive and customized assistance in robot-assisted rehabilitation. This paper presents a mirror Adaptive Assist-As-Needed (AAAN) scheme, including two modules of Multi-Sensors Fused Estimation (MSFE) and Online Incremental Mirror Adaptation (OIMA) , to encourage the subjects to actively participate in rehabilitation. Specifically, the first MSFE module can obtain the needed assistance based on the functional capability of the post-stroke patients via the data fusion of biological and motional signals using Kalman Filter. The second OIMA module fine-tunes the control torques estimated by MSFE to adapt the muscle fatigue and stiffness varieties of the affected limb based on the motion and physiological reference of the mirror healthy limb. The results demonstrate that the AAAN strategy can realize the transparent mode for healthy subjects and promote post-stroke patients to rehabilitate the affected limb with active participation using EMG signals 90.5% similar to those of the mirror healthy limb. The proposed method can be expected to greatly enhance power assistance and rehabilitation outcome of post-stroke patients using exoskeletons by provoking active participation. Note to Practitioners —For robotic rehabilitation, it is crucial to provide suitable assistances that can maximize the participation of post-stroke patients, which can promote the recovery outcome of therapies. The main purpose of this work is to achieve the adaptive assist-as-needed control strategy for upper limb rehabilitation tasks in two steps. Firstly, the elbow joint torques of a post-stroke patient are estimated by data fusion of motion and electromyography (EMG) signals using Kalman Filter, which can make up for the shortcomings of the individual signals, such as poor reliability and low sensitivity. Secondly, the joint motion and EMG signals of the mirror healthy limb are used as the reference to calculate the adaptive needed assistance to rehabilitate the affected limb. The preliminary experiments with healthy and post-stroke subjects demonstrate that this approach can obtain stable motion with the natural physiological states of subjects and enhance active voluntary participation in rehabilitation. In the future study, it will be investigated how to accelerate the adaptation of new patients based on the knowledge of the learned individuals using machine learning methods, such as lifelong learning and incremental learning.

2 January 2023 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
WCWenyuan Chen
Wenyuan Chen
GLGuangyong Li
Guangyong Li
NLNing Li
Ning Li
WWWenxue Wang
Wenxue Wang
PYPeng Yu
Peng Yu
Lianqing LiuLianqing Liu
Lianqing Liu
A significant number of stroke patients are permanently left with a hemiparetic upper limb after the poststroke six-month golden recovery period, resulting in a drastic decline in their quality of life. This study develops a novel foot-controlled hand/forearm exoskeleton that enables patients with hemiparetic hands and forearms to restore their voluntary activities of daily living. Patients can accomplish dexterous hand/arm manipulation on their own with the assistance of a foot-controlled hand/forearm exoskeleton by utilizing foot movements on the unaffected side as command signals. The proposed foot-controlled exoskeleton was first tested on a stroke patient with a chronic hemiparetic upper limb. The testing results showed that the forearm exoskeleton can assist the patient in achieving approximately 107°of voluntary forearm rotation with a static control error less than 1.7°, whereas the hand exoskeleton can assist the patient in realizing at least six different voluntary hand gestures with a success rate of 100%. Further experiments involving more patients demonstrated that the foot-controlled hand/forearm exoskeleton can help patients in restoring some of the voluntary activities of daily living with their paretic upper limb, such as picking up food to eat and opening water bottles to drink, and etc. This research implies that the foot-controlled hand/forearm exoskeleton is a viable way to restore the upper limb activities of stroke patients with chronic hemiparesis.

28 December 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
XCXianyang Chen
Xianyang Chen
NLNing Li
Ning Li
SBShuai Bi
Shuai Bi
XWXiaoguang Wang
Xiaoguang Wang
BWBeinan Wang
Beinan Wang
Conserved protein antigens among serotypes of group A Streptococcus pyogenes (GAS) have been focused for vaccine development because of the diversity of GAS serotypes and risks of autoimmunity post-GAS infection. Precise delineation of protective immune response to each of GAS antigens is critical for vaccine efficacy and safety. We recently reported that immunization with SrtA of GAS provides Th17-dependent clearance of heterologous serotypes of GAS in NALT. SCPA is a surface virulence molecule of GAS and known to induce antibody-mediated protection against GAS. We hypothesized that co-immunization with SrtA and SCPA would provide more efficient protection by eliciting combined Th17 and antibody responses. The present study showed that mice that were intranasally co-immunized with SrtA/SCPA cleared GAS more efficiently than the mice that were immunized with either SrtA or SCPA individually, and as efficient as the mice that experienced repeated GAS infections. The co-immunization induced Th17 and robust SCPA antibody responses, accompanied by a rapid influx of neutrophils and high myeloperoxidase activity in NALT, suggesting that simultaneous induction of mucosal Th17 and neutralizing antibody responses offers more effective GAS elimination through rapid infiltration and activation of neutrophils. Moreover, Th17 response was strongly induced in mice that experienced repeated GAS-infection and maintained at a high level even after the bacteria were cleared; whereas, it was moderately induced and promptly returned to baseline following bacterial elimination in SrtA/SCPA co-immunized mice. Additional results showed that the survival rate of systemic challenge was significantly higher in infection experienced than in co-immunized mice, indicating that more immune elements are required for protection against systemic than mucosal GAS infection.

30 November 2022 in Journal of Bionic Engineering
Verified
Journal Article
Closed access
PDF file
NLNing Li
Ning Li
TYTie Yang
Tie Yang
YYYang Yang
Yang Yang
WCWenyuan Chen
Wenyuan Chen
PYPeng Yu
Peng Yu
WWWenxue Wang
Wenxue Wang