Yasuhide Nakayama

Yasuhide Nakayama

Auto-generated profile, based on publicly available information

Yasuhide Nakayama

Division of Medical Engineering and Materials, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishirodai, Suita, Osaka, 565-8565, Japan.

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2004 in Cell Transplantation
Verified
Journal Article
Open access
YNYasuhide Nakayama
Yasuhide Nakayama
HIHatsue Ishibashi-Ueda
Hatsue Ishibashi-Ueda
KTKeiichi Takamizawa
Keiichi Takamizawa
In this study, vascular-like tubular tissues called biotubes, consisting of autologous tissues, were prepared using in vivo tissue engineering. Their mechanical properties were evaluated for application as a small-caliber artificial vascular prosthesis. The biotubes were prepared by embedding six kinds of polymeric rods [poly(ethylene) (PE), poly(fluoroacetate) (PFA), poly(methyl methacrylate) (PMMA), segmented poly(urethane) (PU), poly(vinyl chloride) (PVC), and silicone (Si)] as a mold in six subcutaneous pouches in the dorsal skin of New Zealand White rabbits. For rods apart from PFA, biotubes were constructed after 1 month of implantation by encapsulation around the polymeric implants. The wall thickness of the biotubes ranged from about 50 to 200 μm depending on the implant material and were in the order PFA < PVC < PMMA < PU < PE. As for PE, PMMA, and PVC, the thickness increased after 3 months of implantation and ranged from 1.5-to 2-fold. None of the biotubes were ruptured when a hydrostatic pressure was gradually applied to their lumen up to 200 mmHg. The relationship between the intraluminal pressure and the external diameter, which was highly reproducible, showed a “J”-shaped curve similar to the native artery. The tissue mostly consisted of collagen-rich extracellular matrices and fibroblasts. Generally, the tissue was relatively firm and inelastic for Si and soft for PMMA. For PMMA, PE, and PVC the stiffness parameter (β value; one of the indexes for compliance) of the biotubes obtained was similar to those of the human coronary, femoral, and carotid arteries, respectively. Biotubes, which possess the ability for wide adjustments in their matrices, mechanics, shape, and luminal surface design, can be applied for use as small-caliber blood vessels and are an ideal implant because they avoid immunological rejection.

21 February 2012 in Accounts of Chemical Research
Verified
Journal Article
Closed access
YNYasuhide Nakayama
Yasuhide Nakayama

8 August 2005 in Journal of Artificial Organs
Verified
Journal Article
Closed access
PDF file
HHHaiying Huang
Haiying Huang
YNYasuhide Nakayama
Yasuhide Nakayama
KQKairong Qin
Kairong Qin
KYKimiko Yamamoto
Kimiko Yamamoto
JAJoji Ando
Joji Ando
YNYasushi Nemoto
Yasushi Nemoto

25 April 2014 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
YNYasuhide Nakayama
Yasuhide Nakayama
YTYoshiaki Takewa
Yoshiaki Takewa
HSHirohito Sumikura
Hirohito Sumikura
MYMasashi Yamanami
Masashi Yamanami
YMYuichi Matsui
Yuichi Matsui
ETEisuke Tatsumi
Eisuke Tatsumi

17 November 2009 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
TWTaiji Watanabe
Taiji Watanabe
KKKeiichi Kanda
Keiichi Kanda
HIHatsue Ishibashi‐Ueda
Hatsue Ishibashi‐Ueda
HYHitoshi Yaku
Hitoshi Yaku
YNYasuhide Nakayama
Yasuhide Nakayama

11 May 2011 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
TWTaiji Watanabe
Taiji Watanabe
KKKeiichi Kanda
Keiichi Kanda
MYMasashi Yamanami
Masashi Yamanami
HIHatsue Ishibashi‐Ueda
Hatsue Ishibashi‐Ueda
HYHitoshi Yaku
Hitoshi Yaku
YNYasuhide Nakayama
Yasuhide Nakayama