Laurel Kuxhaus

Laurel Kuxhaus

Auto-generated profile, based on publicly available information

Laurel Kuxhaus

Mem. ASME Department of Mechanical and Aeronautical Engineering, Clarkson University, 8 Clarkson Avenue, Box 5725, Potsdam, NY 13699

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2011 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
MTMartin L. Tanaka
Martin L. Tanaka
CWCharles A. Weisenbach
Charles A. Weisenbach
MMMark Carl Miller
Mark Carl Miller
LKLaurel Kuxhaus
Laurel Kuxhaus
Developing appropriate mathematical models for biological soft tissues such as ligaments, tendons, and menisci is challenging. Stress-strain behavior of these tissues is known to be continuous and characterized by an exponential toe region followed by a linear elastic region. The conventional curve-fitting technique applies a linear curve to the elastic region followed by a separate exponential curve to the toe region. However, this technique does not enforce continuity at the transition between the two regions leading to inaccuracies in the material model. In this work, a Continuous Method is developed to fit both the exponential and linear regions simultaneously, which ensures continuity between regions. Using both methods, three cases were evaluated: idealized data generated mathematically, noisy idealized data produced by adding random noise to the idealized data, and measured data obtained experimentally. In all three cases, the Continuous Method performed superiorly to the conventional technique, producing smaller errors between the model and data and also eliminating discontinuities at the transition between regions. Improved material models may lead to better predictions of nonlinear biological tissues’ behavior resulting in improved the accuracy for a large array of models and computational analyses used to predict clinical outcomes.

1 March 2015 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
ATAlexander D. W. Throop
Alexander D. W. Throop
ALAlexander K. Landauer
Alexander K. Landauer
ACAlexander Martin Clark
Alexander Martin Clark
LKLaurel Kuxhaus
Laurel Kuxhaus
Animal models for orthopaedic implant testing are well-established but morphologically dissimilar to human tibiae; notably, most are shorter. The purpose of this study was to quantitatively evaluate the morphology and mechanical properties of the cervine tibia, particularly with regard to its suitability for testing orthopaedic implants. Two endosteal and eleven periosteal measurements were made on 15 cervine tibiae. The mechanical strength in axial compression and torsion was measured using 11 tibiae. The cervine tibia is morphologically similar to the human tibia and more closely matches the length of the human tibia than current tibia models (ovine, porcine, and caprine). The distal epiphysis dimensions are notably different, but no more so than the current tibia models. The torsional stiffness of the cervine tibia is within the range of previously reported values for human tibiae. Furthermore, in many regions, cervine tibiae are abundant and locally available at a low cost. Given these mechanical and morphological data, coupled with potential cost savings if regionally available, the cervine tibia may be an appropriate model for orthopaedic implant testing.

6 May 2014 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
NCNicole C. Corbiere
Nicole C. Corbiere
KLKathleen A. Lewicki
Kathleen A. Lewicki
KIKathleen A. Issen
Kathleen A. Issen
LKLaurel Kuxhaus
Laurel Kuxhaus
Approximately 50% of women and 25% of men will have an osteoporosis-related fracture after the age of 50, yet the micromechanical origin of these fractures remains unclear. Preventing these fractures requires an understanding of compression fracture formation in vertebral cancellous bone. The immediate research goal was to create clinically relevant (midvertebral body and endplate) fractures in three-vertebrae motion segments subject to physiologically realistic compressional loading conditions. Six three-vertebrae motion segments (five cervine, one cadaver) were potted to ensure physiologic alignment with the compressive load. A 3D microcomputed tomography (microCT) image of each motion segment was generated. The motion segments were then preconditioned and monotonically compressed until failure, as identified by a notable load drop (48–66% of peak load in this study). A second microCT image was then generated. These three-dimensional images of the cancellous bone structure were inspected after loading to qualitatively identify fracture location and type. The microCT images show that the trabeculae in the cervine specimens are oriented similarly to those in the cadaver specimen. In the cervine specimens, the peak load prior to failure is highest for the L4–L6 motion segment, and decreases for each cranially adjacent motion segment. Three motion segments formed endplate fractures and three formed midvertebral body fractures; these two fracture types correspond to clinically observed fracture modes. Examination of normalized-load versus normalized-displacement curves suggests that the size (e.g., cross-sectional area) of a vertebra is not the only factor in the mechanical response in healthy vertebral specimens. Furthermore, these normalized-load versus normalized-displacement data appear to be grouped by the fracture type. Taken together, these results show that (1) the loading protocol creates fractures that appear physiologically realistic in vertebrae, (2) cervine vertebrae fracture similarly to the cadaver specimen under these loading conditions, and (3) that the prefracture load response may predict the impending fracture mode under the loading conditions used in this study.

7 June 2016 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
LKLaurel Kuxhaus
Laurel Kuxhaus
NCNicole C. Corbiere
Nicole C. Corbiere
Current engineering pedagogy primarily focuses on developing technical proficiency and problem solving skills; the peer-review process for sharing new research results is often overlooked. The use of a collaborative classroom journal club can engage students with the excitement of scientific discovery and the process of dissemination of research results, which are also important lifelong learning skills. In this work, a classroom journal club was implemented and a survey of student perceptions spanning three student cohorts was collected. In this collaborative learning activity, students regularly chose and discussed a recent biomechanics journal article, and were assessed based on specific, individual preparation tasks. Most student-chosen journal articles were relevant to topics discussed in the regular class lecture. Surveys assessed student perceptions of the activity. The survey responses show that, across all cohorts, students both enjoyed the classroom journal club and recognized it as an important learning experience. Many reported discussing their journal articles with others outside of the classroom, indicating good engagement. The results demonstrate that student engagement with primary literature can foster both technical knowledge and lifelong learning skills.

12 January 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MHMark J. Hedgeland
Mark J. Hedgeland
MLMorgan A. Libruk
Morgan A. Libruk
NCNicole C. Corbiere
Nicole C. Corbiere
MCMario J. Ciani
Mario J. Ciani
LKLaurel Kuxhaus
Laurel Kuxhaus
Biomechanical research relies heavily on laboratory evaluation and testing with osseous animal structures. While many femora models are currently in use, including those of the European red deer (Cervus elaphus), the Odocoileus virginianus femur remains undocumented, despite its regional abundance in North America. The objective of this study was to compare biomechanical and morphological properties of the Odocoileus virginianus femur with those of the human and commonly used animal models. Sixteen pairs of fresh-frozen cervine femora (10 male, 6 female, aged 2.1 ± 0.9 years) were used for this study. Axial and torsional stiffnesses (whole bone) were calculated following compression and torsion to failure tests (at rates of 0.1 mm/sec and 0.2°/sec). Lengths, angles, femoral head diameter and position, periosteal and endosteal diaphyseal dimensions, and condylar dimensions were measured. The results show that the cervine femur is closer in length, axial and torsional stiffness, torsional strength, and overall morphology to the human femur than many other commonly used animal femora models; additional morphological measurements are comparable to many other species’ femora. The distal bicondylar width of 59.3mm suggests that cervine femora may be excellent models for use in total knee replacement simulations. Furthermore, the cervine femoral head is more ovoid than other commonly-used models for hip research, making it a more suitable model for studies of hip implants. Thus, with further, more application-specific investigations, the cervine femur could be a suitable model for biomechanical research, including the study of ballistic injuries and orthopaedic device development.

1 March 2014 in Journal of Biomechanics
Verified
Journal Article
Closed access
LKLaurel Kuxhaus
Laurel Kuxhaus
SZSisi Zeng
Sisi Zeng
CRCharles J. Robinson
Charles J. Robinson