Mark Anthony Fernance Kendall

Mark Anthony Fernance Kendall

Auto-generated profile, based on publicly available information

Mark Anthony Fernance Kendall

Delivery of Drugs and Genes Group (D2G2), Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, Queensland, Australia

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JWJonathan Wei
Jonathan Wei
GEGrant A. Edwards
Grant A. Edwards
DMDarren James Martin
Darren James Martin
HHHan Huang
Han Huang
MCMichael Crichton
Michael Crichton
MKMark A. F. Kendall
Mark A. F. Kendall
Emerging micro-scale medical devices are showing promise, whether in delivering drugs or extracting diagnostic biomarkers from skin. In progressing these devices through animal models towards clinical products, understanding the mechanical properties and skin tissue structure with which they interact will be important. Here, through measurement and analytical modelling, we advanced knowledge of these properties for commonly used laboratory animals and humans (~30 g to ~150 kg). We hypothesised that skin’s stiffness is a function of the thickness of its layers through allometric scaling, which could be estimated from knowing a species’ body mass. Results suggest that skin layer thicknesses are proportional to body mass with similar composition ratios, inter- and intra-species. Experimental trends showed elastic moduli increased with body mass, except for human skin. To interpret the relationship between species, we developed a simple analytical model for the bulk elastic moduli of skin, which correlated well with experimental data. Our model suggest that layer thicknesses may be a key driver of structural stiffness, as the skin layer constituents are physically and therefore mechanically similar between species. Our findings help advance the knowledge of mammalian skin mechanical properties, providing a route towards streamlined micro-device research and development onto clinical use.

27 July 2010 in Small
Verified
Journal Article
Closed access
PDF file
TPTarl Prow
Tarl Prow
XCXianfeng Chen
Xianfeng Chen
NPNatalie Prow
Natalie Prow
Germain J FernandoGermain J Fernando
Germain J Fernando
CTCindy S. E. Tan
Cindy S. E. Tan
MKMark A. F. Kendall
Mark A. F. Kendall

21 April 2010 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Germain J FernandoGermain J Fernando
Germain J Fernando
XCXianfeng Chen
Xianfeng Chen
TPTarl Prow
Tarl Prow
MCMichael Crichton
Michael Crichton
EFEmily J. Fairmaid
Emily J. Fairmaid
MKMark A. F. Kendall
Mark A. F. Kendall
Over 14 million people die each year from infectious diseases despite extensive vaccine use [1]. The needle and syringe—first invented in 1853—is still the primary delivery device, injecting liquid vaccine into muscle. Vaccines could be far more effective if they were precisely delivered into the narrow layer just beneath the skin surface that contains a much higher density of potent antigen-presenting cells (APCs) essential to generate a protective immune response. We hypothesized that successful vaccination could be achieved this way with far lower antigen doses than required by the needle and syringe. To meet this objective, using a probability-based theoretical analysis for targeting skin APCs, we designed the Nanopatch™, which contains an array of densely packed projections (21025/cm2) invisible to the human eye (110 µm in length, tapering to tips with a sharpness of <1000 nm), that are dry-coated with vaccine and applied to the skin for two minutes. Here we show that the Nanopatches deliver a seasonal influenza vaccine (Fluvax® 2008) to directly contact thousands of APCs, in excellent agreement with theoretical prediction. By physically targeting vaccine directly to these cells we induced protective levels of functional antibody responses in mice and also protection against an influenza virus challenge that are comparable to the vaccine delivered intramuscularly with the needle and syringe—but with less than 1/100th of the delivered antigen. Our results represent a marked improvement—an order of magnitude greater than reported by others—for injected doses administered by other delivery methods, without reliance on an added adjuvant, and with only a single vaccination. This study provides a proven mathematical/engineering delivery device template for extension into human studies—and we speculate that successful translation of these findings into humans could uniquely assist with problems of vaccine shortages and distribution—together with alleviating fear of the needle and the need for trained practitioners to administer vaccine, e.g., during an influenza pandemic.

21 July 2010 in Small
Verified
Journal Article
Closed access
PDF file
ARAnthony P. Raphael
Anthony P. Raphael
TPTarl Prow
Tarl Prow
MCMichael Crichton
Michael Crichton
XCXianfeng Chen
Xianfeng Chen
Germain J FernandoGermain J Fernando
Germain J Fernando
MKMark A. F. Kendall
Mark A. F. Kendall

1 November 2007 in Biomaterials
Verified
Journal Article
Closed access
MKMark A.F. Kendall
Mark A.F. Kendall
YCYu-Foong Chong
Yu-Foong Chong
ACAlexander Cock
Alexander Cock

18 October 2010 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HCHolly J. Corbett
Holly J. Corbett
Germain J FernandoGermain J Fernando
Germain J Fernando
XCXianfeng Chen
Xianfeng Chen
IFIan Frazer
Ian Frazer
MKMark A. F. Kendall
Mark A. F. Kendall
Better delivery systems are needed for routinely used vaccines, to improve vaccine uptake. Many vaccines contain alum or alum based adjuvants. Here we investigate a novel dry-coated densely-packed micro-projection array skin patch (Nanopatch™) as an alternate delivery system to intramuscular injection for delivering an alum adjuvanted human papillomavirus (HPV) vaccine (Gardasil®) commonly used as a prophylactic vaccine against cervical cancer. Micro-projection arrays dry-coated with vaccine material (Gardasil®) delivered to C57BL/6 mouse ear skin released vaccine within 5 minutes. To assess vaccine immunogenicity, doses of corresponding to HPV-16 component of the vaccine between 0.43±0.084 ng and 300±120 ng (mean ± SD) were administered to mice at day 0 and day 14. A dose of 55±6.0 ng delivered intracutaneously by micro-projection array was sufficient to produce a maximal virus neutralizing serum antibody response at day 28 post vaccination. Neutralizing antibody titres were sustained out to 16 weeks post vaccination, and, for comparable doses of vaccine, somewhat higher titres were observed with intracutaneous patch delivery than with intramuscular delivery with the needle and syringe at this time point. Use of dry micro-projection arrays (Nanopatch™) has the potential to overcome the need for a vaccine cold chain for common vaccines currently delivered by needle and syringe, and to reduce risk of needle-stick injury and vaccine avoidance due to the fear of the needle especially among children.