Gökhan Keven

Dr. Gökhan Keven

Department of Electronic and Automation, Nevşehir Hacı Bektaş Veli University, Nevşehir, Turkey (Türkiye)
orcid
Nevsehir Haci Bektas Veli University

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2013
Verified
Conference Paper
Closed access
ICIlhami Colak
Ilhami Colak
Ersan KabalciErsan Kabalci
Ersan Kabalci
Gökhan KevenGökhan Keven
Gökhan Keven
The multilevel inverters (MLIs) are classified into three topologies such as Diode Clamped, Flying Capacitor and Cascade Multilevel Inverter (CMLI). CMLI topologies include two kind of structure that is named symmetric and asymmetric topologies. Asymmetric Cascade MLI (ACMLI) topologies consist of unequal DC sources. Many modulation techniques have been used in ACMLI topology such as Multi-Carrier PWM (MC-PWM), Space Vector PWM and Selective Harmonic PWM. The MC-PWM technique is achieved by four different types. In this study, MC-PWM techniques which are named Phase Disposition PWM, Phase Opposition Disposition PWM, Alternate Phase Opposition Disposition PWM and Phase Shifted PWM have been compared. It is uncovered that Phase Opposition Disposition PWM technique is more convenient in terms of Total Harmonic Distortion of output voltage and current signals and in terms of the quality of power factor in ACMLI which is performed in this study.

1 January 2021
Verified
Book Chapter
Closed access
ICIlhami Colak
Ilhami Colak
EKErsan Kabalcı
Ersan Kabalcı
Gökhan KevenGökhan Keven
Gökhan Keven

1 September 2014
Verified
Conference Paper
Closed access
ICIlhami Colak
Ilhami Colak
Ersan KabalciErsan Kabalci
Ersan Kabalci
Gökhan KevenGökhan Keven
Gökhan Keven
The Current control of voltage source inverters are realized by many techniques such as Proportional Integral (PI), Proportional Resonant (PR) and Hysteresis Current Control. The PR control works on an αβ frame and it involves less calculation process comparing to PI control. The αβ frame should be converted to dq frame in PI control. The PR control can easily implemented with digital control techniques due to the slow sampling frequency. PR control has very high proportional and integral gain at resonance frequency where it can mitigate low order harmonics. PR control can be implemented with other digital control techniques. In this study, a Seven-Level asymmetric cascade multilevel inverter simulation is realized with PR control. As a result of structure developed, the Total Harmonic Distortion (THD) is more lowered with respect to the structure without using PR control.

1 November 2019
Verified
Conference Paper
Closed access
ICIlhami Colak
Ilhami Colak
EKErsan Kabalci
Ersan Kabalci
Gökhan KevenGökhan Keven
Gökhan Keven
Energy conversion is a crucial requirement of renewable energy systems. The DC-AC inverters are essential devices to convert the generated energy of wind turbines and solar panels. Multilevel Inverters (MLI) have wide application areas in the industry. There are numerous digital control techniques used for multilevel inverters. Nowadays, digital signal processors (DSP) are the most popular controllers for MLI control algorithms. Programming a DSP requires some specifications such as algorithm, coding and compiling the program. Matlab/Simulink software is often used in simulation of engineering systems. This software has some properties to program DSPs by using Simulink blocks. Therefore, researchers do not need programming DSPs by coding, and can be able to perform experiments rapidly. In this study, 3-level cascaded H-Bridge MLI is realized by using DSP with programming Simulink. The total harmonic distortion (THD) of the MLI must be decreased for pure sinusoidal wave. Proportional resonant (PR) control is implemented in MLI for this purpose. The PR control, which decreases THD of the system, is one of the most recent current control methods. In this paper, effect of PR control is analyzed in simulation and experimental studies. It is obtained from results that the PR control can be able to decrease the THD, especially the low order harmonics.

1 January 2021
Verified
Book Chapter
Closed access
ICIlhami Colak
Ilhami Colak
EKErsan Kabalcı
Ersan Kabalcı
Gökhan KevenGökhan Keven
Gökhan Keven

25 April 2026 in Electronics
Verified
Journal Article
Open access
PDF file
Gökhan KevenGökhan Keven
Gökhan Keven
IÇİlhami Çolak
İlhami Çolak
Ersan KabalciErsan Kabalci
Ersan Kabalci
Asymmetric Cascaded Multilevel Inverters (ACMLIs) have emerged as a prominent solution for medium- and high-power applications due to their ability to provide an increased number of output voltage levels with fewer power switches. However, maintaining low total harmonic distortion (THD) and ensuring robust stability under varying operating conditions remain significant challenges. This study experimentally validates a voltage-feedback Proportional-Resonant (PR) control strategy for a seven-level ACMLI. Unlike conventional current-feedback methods, the proposed approach directly regulates the output voltage, providing superior harmonic suppression and enhanced steady-state accuracy. The stability and dynamic performance of the controller were theoretically analyzed using Bode diagrams and root locus methods, and further verified through the MATLAB Curve Fitting Tool (CFT) with a high correlation (R2 = 0.9989). Experimental results demonstrate that the integration of the PR controller significantly improves power quality, reducing the current THD from 6.55% to 3.68% and the voltage THD to 2.94%. These findings confirm that the system fully complies with IEEE 519 standards and outperforms several existing strategies in the literature. The results establish the voltage-feedback PR control as a robust, high-precision, and practical alternative for power quality-oriented multilevel inverter applications in modern energy systems.