Geophysical investigation for engineering studies was carried out around Faith Academy, Marmara village, Kaduna within the basement complex of North-Western Nigeria. Six Vertical Electrical Sounding (VES) were established using Schlumberger configuration. The geoelectric section revealed five subsurface layers defined by the topsoil, which comprises humus, clay and laterite; followed by weathered layer which comprises of sandy soil, fractured layer which constitutes of coarse grain sands and gravels and fresh basement which is porphyritic granite. The resistivities and thicknesses of the topsoil range from 47 - 4212 ?m and 2 - 5 m respectively. The weathered/fractured basement has average thickness of 42 m with resistivity ranging from 350 - 774 ?m. The Areas found to meet the conditions of high basement resistivity and shallow depth to basement, are found to be at VES A1, A2, A3, A4 and A6. Hence, VES A1 have been found to be the competent zones within the study area, and are good for the construction of high-rise buildings, roads and bridges. VES A3, A4 and A6 are areas that do not meet the conditions for construction of a high-rise buildings. However, VES A3, A4 and A6 appears to be viable for groundwater exploration with aquifer thickness ranges between 18 - 42 m and depth ranges of 6 - 10 m, while the average depth to fresh basement is 43 m.
10 January 2017 in British Journal of Applied Science & Technology
A geoelectrical survey was carried out in order to evaluate the groundwater potential of ABU Zaria, Nigeria. A total of four Vertical Electrical Soundings (VES) were carried out using Schlumberger electrode configuration with half current electrode spacing of maximum 100 m. The Interpreted data revealed that the study area is underlain by three to four layers. The topsoil thickness and resistivity values vary from 0.4 – 2.0 m and 186 – 833 Ωm respectively. The thickness and resistivity of the weathered basement ranges between 3.0 – 15.2 m and 109 – 360 Ωm respectively. The fresh basement layer which has resistivity values of 1603 – 49788 Ωm is of infinite depth and thickness. The areas with relatively high thickness and low resistivity values of the weathered layer and fractured bedrock have been successfully identified as potential aquifer zone targets for groundwater exploitation.
This study explores the application of Physics-Informed Neural Networks (PINNs) to solve the two-dimensional steady incompressible Navier-Stokes equations, focusing on Poiseuille flow in a rectangular channel. Implemented using the DeepXDE library with a TensorFlow 1.x backend, the PINN embeds the governing partial differential equations and boundary conditions into its loss function. The neural network architecture consists of four hidden layers, each with 64 neurons. A hybrid optimization strategy, combining Adam (10,000 steps) and LBFGS-B, ensured robust convergence. The composite loss function, comprising seven components (three for momentum and continuity equations, four for boundary conditions), decreased significantly, achieving a total test loss of 8.71 × 10ିହ at step 9000. The predicted x-velocity component (u) was evaluated against the analytical Poiseuille solution, yielding an 𝐿ଶ relative error of 0.0861 (8.61%). Visual comparisons confirm that the PINN accurately captures the parabolic velocity profile characteristic of Poiseuille flow. This work underscores the potential of PINNs as a data-efficient, mesh-free approach for solving fundamental fluid dynamics problems, paving the way for their application to more complex flow scenarios.
Shape-memory alloys have the potential to provide a large range of reconfigurability within mechanically reconfigurable antenna designs. This paper presents a study on the use of Shape-memory alloys in providing reconfigurability in antennas. First an assessment of the suitability of Shape-memory alloys for use within antenna design was conducted. Secondly a proof of concept reconfigurable square loop antenna prototype is implemented using Shape-memory alloys as the radiating element. Shape-memory alloys are used to adjust the loop circumference and therefore the antenna's resonant frequency. Simulation and measurements confirm that the antenna is reconfigurable, although the desired reconfigurability was not achieved.