Ian Costanzo

Mr. Ian Costanzo

Worcester Polytechnic Institute, Worcester, Massachusetts, USA
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2020 in IEEE Reviews in Biomedical Engineering
Verified
Journal Article
Closed access
ICIan Costanzo
Ian Costanzo
DSDEVDIP SEN
DEVDIP SEN
LRLawrence Rhein
Lawrence Rhein
Ulkuhan GulerUlkuhan Guler
Ulkuhan Guler
In this article, we present current methodologies, available technologies, and demands for monitoring various respiratory parameters. We discuss the importance of noninvasive techniques for remote and continuous monitoring and challenges involved in the current "smart and connected health" era. We conducted an extensive literature review on the medical significance of monitoring respiratory vital parameters, along with the current methods and solutions with their respective advantages and disadvantages. We discuss the challenges of developing a noninvasive, wearable, wireless system that continuously monitors respiration parameters and opportunities in the field and then determines the requirements of a state-of-the-art system. Noninvasive techniques provide a significant amount of medical information for a continuous patient monitoring system. Contact methods offer more advantages than non-contact methods; however, reducing the size and power of contact methods is critical for enabling a wearable, wireless medical monitoring system. Continuous and accurate remote monitoring, along with other physiological data, can help caregivers improve the quality of care and allow patients greater freedom outside the hospital. Such monitoring systems could lead to highly tailored treatment plans, shorten patient stays at medical facilities, and reduce the cost of treatment.

1 June 2021 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
ICIan Costanzo
Ian Costanzo
DSDEVDIP SEN
DEVDIP SEN
JAJoseph Adegite
Joseph Adegite
PRPratap M. Rao
Pratap M. Rao
Ulkuhan GulerUlkuhan Guler
Ulkuhan Guler
Transcutaneous monitoring is a noninvasive method to continuously measure the partial pressures of oxygen and carbon dioxide that diffuse through the skin and correlate closely with changes in blood gases. However, the contemporary commercially available electrochemical-based technology requires a heating mechanism and a bulky, corded, and expensive sensing unit. This study aims to demonstrate a prototype noninvasive, miniaturized monitor that uses luminescence-based technology to measure the partial pressure of transcutaneous oxygen, a surrogate of the partial pressure of arterial oxygen. To be able to build a robust measurement system, we conducted experiments to understand the temperature and humidity dependence of oxygen-sensitive platinum-porphyrin films. We performed a detailed analysis of both intensity and lifetime measurement techniques. To verify the performance, we tested the prototype in a small ex-vivo experiment involving three healthy human volunteers. We measured variations in the partial pressure of transcutaneous oxygen values due to pressure-induced arterial and venous occlusions on the volunteers’ fingertips. The system resolves changes in the partial pressure of oxygen from 0 to 418 mmHg in the lab bench-top testing, covering the medically relevant range of 50-150 mmHg. Under fixed humidity, temperature, and the partial pressure of oxygen conditions, the sensor shows a 2% drift over 60 hours. The prototype consumes 9 mW of power from a 2.2 V external DC power supply.

20 November 2020 in IEEE Solid-State Circuits Magazine
Verified
Journal Article
Closed access
Ulkuhan GulerUlkuhan Guler
Ulkuhan Guler
ICIan Costanzo
Ian Costanzo
DSDEVDIP SEN
DEVDIP SEN
The world has been in combat with COVID-19 since December 2019. The United States has been paralyzed, with the highest number of cases and more deaths than any other country. However, the disease has devastated almost every nation across the globe, from the Far East to Europe, Latin America, Russia, and India.

30 April 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
ACAatreya Chakravarti
Aatreya Chakravarti
AMAmin Hazrati Marangalou
Amin Hazrati Marangalou
ICIan Costanzo
Ian Costanzo
DSDEVDIP SEN
DEVDIP SEN
MSMirco Sciulli
Mirco Sciulli
Ulkuhan GulerUlkuhan Guler
Ulkuhan Guler
Visualizing neuronal activation and neurotransmitter release by using fluorescent sensors is increasingly popular. The main drawback of contemporary multi-color or multi-region fiber photometry systems is the tethered structure that prevents the free movement of the animals. Although wireless photometry devices exist, a review of literature has shown that these devices can only optically stimulate or excite with a single wavelength simultaneously, and the lifetime of the battery is short. To tackle this limitation, we present a prototype for implementing a fully wireless photometry system with multi-color and multi-region functions. This paper introduces an integrated circuit (IC) prototype fabricated in TSMC 180 nm CMOS process technology. The prototype includes 3-channel optical excitation, 2-channel optical recording, wireless power transfer, and wireless data telemetry blocks. The recording front end has an average gain of 107 dB and consumes 620 μW of power. The light-emitting diode (LED) driver block provides a peak current of 20 mA for optical excitation. The rectifier, the core of the wireless power transmission, operates with 63% power conversion efficiency at 13.56 MHz and a maximum of 87% at 2 MHz. The system is validated in a laboratory bench test environment and compared with state-of-the-art technologies. The optical excitation and recording front end and the wireless power transfer circuit evaluated in this paper will form the basis for a future miniaturized final device with a shank that can be used in in vivo experiments.

20 December 2024 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
ICIan Costanzo
Ian Costanzo
DSDEVDIP SEN
DEVDIP SEN
JMJohn McNeill
John McNeill
Ulkuhan GulerUlkuhan Guler
Ulkuhan Guler
This article presents a novel technique that is immune to offset, enabling precise determination of the lifetime of luminescent materials. The technique is specifically applied to measure transcutaneous oxygen, an indicator of oxygen that diffuses through the skin and reflects arterial oxygen levels. Unlike intensity-based measurements, lifetime-based luminescence measurements are superior because they decouple oxygen information from confounding factors. The technique presented in this work involves measuring the time difference between fixed-voltage steps to extract the time constant of a decaying exponential, which represents the lifetime of luminescence. We propose a novel switched-capacitor circuit that enables long integration times and prevents the front-end amplifier from saturating. The analog subsystem was realized in 180-nm CMOS technology via a transimpedance amplifier (TIA) with a gain bandwidth product of 10 MHz, a comparator, and a switched capacitor circuit. The measured mean error is as accurate as 1.9% without postprocessing. During a 130 $\mu$ s measurement period, the readout circuit consumes a maximum of 16 $\mu$ J per calculation with a $\text{FoM}_W$ $=$ 177 nJ/conv. Preliminary human subject tests have demonstrated that the sensor can effectively detect changes in transcutaneous oxygen levels resulting from arterial occlusion.