Milene Zanella Capitanio

Dr. Milene Zanella Capitanio

Community University of Chapecó Region - Unochapecó, Chapecó, Santa Catarina, Brazil
orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2025 in South Asian Journal of Social Studies and Economics
Verified
Journal Article
Closed access
TPTailana Pinheiro
Tailana Pinheiro
MCMilene Zanella Capitanio
Milene Zanella Capitanio
GDGabrielly Dalagasperina
Gabrielly Dalagasperina
LMLaura Salvatori Michels
Laura Salvatori Michels
EMEduarda Caroline Ceriolli Martinello
Eduarda Caroline Ceriolli Martinello
JLJunir Antônio Lutinski
Junir Antônio Lutinski
International immigration is a multidimensional phenomenon, with its causes reflecting political, economic, and cultural contexts, often related to forced displacement. This study was conducted through a narrative review based on the analysis of materials discussing the living conditions, health, and agency of international immigrants, particularly those from countries in the Global South, who are in situations of social vulnerability. The results highlight that, in general, international immigrants are subjected to environments characterized by precarious living and working conditions in the host country, which negatively impact their health and quality of life. Despite these adverse circumstances, immigrants do not become mere passive spectators of their situation; instead, they develop strategies of resistance and adaptation, relying on their social networks to face daily challenges. However, it is important to note that such collective initiatives do not replace the need for public policies that guarantee rights and promote effective social integration.

7 October 2025 in Biomedicines
Verified
Journal Article
Open access
PDF file
Raphael BertaniRaphael Bertani
Raphael Bertani
GSGabriel Semione
Gabriel Semione
MCMilene Zanella Capitanio
Milene Zanella Capitanio
Sérgio BrasilSérgio Brasil
Sérgio Brasil
SBSávio Batista
Sávio Batista
FPFernando Campos Gomes Pinto
Fernando Campos Gomes Pinto
Background/Objectives: Ventriculoperitoneal shunts are the standard treatment for adults diagnosed with several CSF disorders, but often face dysfunction, leading interest in non-invasive methods for diagnosing shunt issues. This study evaluates the potential of non-invasive intracranial pressure waveform monitoring (nICPw) with the brain4care (B4C) system to distinguish overdrainage, underdrainage, and normal shunt function in patients with CSF disorders. Methods: In this single-center, observational study at Hospital das Clínicas, Brazil, adult patients with CSF shunts were enrolled. Patients were categorized as Overdrainage or Underdrainage, based on clinical parameters, with an Asymptomatic group. The B4C system provided nICPw monitoring, and six parameters (including various P2/P1 ratios) were analyzed via MANOVA and ANOVA. Results: Among 30 patients (6 overdrainage, 6 underdrainage, 18 asymptomatic), five asymptomatic patients were excluded from the main analysis due to incomplete data collection, leaving 25 patients. Overdrainage patients had significantly higher ΔP2/P1 values (0.618 ± 0.210) than asymptomatic ones (0.227 ± 0.171). After excluding outliers, differences were more pronounced (H = 10.89; p < 0.01). Underdrainage patients had intermediate ΔP2/P1 values (0.387 ± 0.179) and consistently higher P2/P1 averages (>1.3). ROC analysis indicated that ΔP2/P1 > 0.3 suggested shunt dysfunction (AUC = 0.731), while the highest P2/P1 offered stronger discrimination (AUC = 0.782). A global average P2/P1 > 1.3 was linked to underdrainage, with the lowest P2/P1 values differentiating overdrainage (0.948 ± 0.321) from underdrainage (1.143 ± 0.156). Conclusions: nICPw monitoring with the B4C system demonstrated potential for detecting shunt dysfunction. Combining parameters, especially ΔP2/P1 and highest P2/P1, improves diagnostic accuracy, offering a non-invasive method that may aid in distinguishing normal from abnormal shunt function.