Nikos Efthimiou

Dr. Nikos Efthimiou

Nuclear Medicine, UMC Groningen, Groningen, The Netherlands
orcid

Research Focus & Metrics

Representative Publications

View All Publications
11 May 2021 in Nature Communications
Verified
Journal Article
Open access
PDF file
DWD. P. Watts
D. P. Watts
JBJ. Bordes
J. Bordes
JBJ. R. Brown
J. R. Brown
ACA. Cherlin
A. Cherlin
RNR. Newton
R. Newton
NZNicholas Zachariou
Nicholas Zachariou
Positron Emission Tomography (PET) is a widely-used imaging modality for medical research and clinical diagnosis. Imaging of the radiotracer is obtained from the detected hit positions of the two positron annihilation photons in a detector array. The image is degraded by backgrounds from random coincidences and in-patient scatter events which require correction. In addition to the geometric information, the two annihilation photons are predicted to be produced in a quantum-entangled state, resulting in enhanced correlations between their subsequent interaction processes. To explore this, the predicted entanglement in linear polarisation for the two photons was incorporated into a simulation and tested by comparison with experimental data from a cadmium zinc telluride (CZT) PET demonstrator apparatus. Adapted apparati also enabled correlation measurements where one of the photons had undergone a prior scatter process. We show that the entangled simulation describes the measured correlations and, through simulation of a larger preclinical PET scanner, illustrate a simple method to quantify and remove the unwanted backgrounds in PET using the quantum entanglement information alone.

1 November 2020 in NeuroImage
Verified
Journal Article
Open access
FLFrancisco J. López-González
Francisco J. López-González
Jesús Silva-RodríguezJesús Silva-Rodríguez
Jesús Silva-Rodríguez
JPJosé Paredes-Pacheco
José Paredes-Pacheco
ANAida Niñerola-Baizán
Aida Niñerola-Baizán
NENikos Efthimiou
Nikos Efthimiou
PAPablo Aguiar
Pablo Aguiar
The lack of standardization of intensity normalization methods and its unknown effect on the quantification output is recognized as a major drawback for the harmonization of brain FDG-PET quantification protocols. The aim of this work is the ground truth-based evaluation of different intensity normalization methods on brain FDG-PET quantification output. Realistic FDG-PET images were generated using Monte Carlo simulation from activity and attenuation maps directly derived from 25 healthy subjects (adding theoretical relative hypometabolisms on 6 regions of interest and for 5 hypometabolism levels). Single-subject statistical parametric mapping (SPM) was applied to compare each simulated FDG-PET image with a healthy database after intensity normalization based on reference regions methods such as the brain stem (RRBS), cerebellum (RRC) and the temporal lobe contralateral to the lesion (RRTL), and data-driven methods, such as proportional scaling (PS), histogram-based method (HN) and iterative versions of both methods (iPS and iHN). The performance of these methods was evaluated in terms of the recovery of the introduced theoretical hypometabolic pattern and the appearance of unspecific hypometabolic and hypermetabolic findings. Detected hypometabolic patterns had significantly lower volumes than the introduced hypometabolisms for all intensity normalization methods particularly for slighter reductions in metabolism . Among the intensity normalization methods, RRC and HN provided the largest recovered hypometabolic volumes, while the RRBS showed the smallest recovery. In general, data-driven methods overcame reference regions and among them, the iterative methods overcame the non-iterative ones. Unspecific hypermetabolic volumes were similar for all methods, with the exception of PS, where it became a major limitation (up to 250 cm3) for extended and intense hypometabolism. On the other hand, unspecific hypometabolism was similar far all methods, and usually solved with appropriate clustering. Our findings showed that the inappropriate use of intensity normalization methods can provide remarkable bias in the detected hypometabolism and it represents a serious concern in terms of false positives. Based on our findings, we recommend the use of histogram-based intensity normalization methods. Reference region methods performance was equivalent to data-driven methods only when the selected reference region is large and stable.

22 March 2019 in Inverse Problems
Verified
Journal Article
Open access
PDF file
DDDaniel Deidda
Daniel Deidda
NKNicolas Karakatsanis
Nicolas Karakatsanis
PRPhilip M Robson
Philip M Robson
YTYu-Jung Tsai
Yu-Jung Tsai
NENikos Efthimiou
Nikos Efthimiou
CTCharalampos Tsoumpas
Charalampos Tsoumpas

31 December 2020 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Open access
NENikos Efthimiou
Nikos Efthimiou
NKNicolaus Kratochwil
Nicolaus Kratochwil
SGStefan Gundacker
Stefan Gundacker
APAndrea Polesel
Andrea Polesel
MSMatteo Salomoni
Matteo Salomoni
MPMarco Pizzichemi
Marco Pizzichemi
Today Time-of-Flight (TOF), in PET scanners, assumes a single, well-defined timing resolution for all events. However, recent BGO-Cherenkov detectors, combining prompt Cherenkov emission and the typical BGO scintillation, can sort events into multiple timing kernels, best described by the Gaussian mixture models. The number of Cherenkov photons detected per event impacts directly the detector time resolution and signal rise time, which can later be used to improve the coincidence timing resolution. This work presents a simulation toolkit which applies multiple timing spreads on the coincident events and an image reconstruction that incorporates this information. A full cylindrical BGO-Cherenkov PET model was compared, in terms of contrast recovery and contrast-to-noise ratio, against an LYSO model with a time resolution of 213 ps. Two reconstruction approaches for the mixture kernels were tested: 1) mixture Gaussian and 2) decomposed simple Gaussian kernels. The decomposed model used the exact mixture component applied during the simulation. Images reconstructed using mixture kernels provided similar mean value and less noise than the decomposed. However, typically, more iterations were needed. Similarly, the LYSO model, with a single TOF kernel, converged faster than the BGO-Cherenkov with multiple kernels. The results indicate that the model complexity slows down convergence. However, due to the higher sensitivity, the contrast-to-noise ratio was 26.4% better for the BGO model.

28 October 2013 in Medical Physics
Verified
Journal Article
Closed access
PPPanagiotis Papadimitroulas
Panagiotis Papadimitroulas
GLGeorge Loudos
George Loudos
AMAmandine Le Maitre
Amandine Le Maitre
MHMathieu Hatt
Mathieu Hatt
FTFlorent Tixier
Florent Tixier
GKGeorge C. Kagadis
George C. Kagadis

19 December 2018 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
NENikos Efthimiou
Nikos Efthimiou
EEElise Emond
Elise Emond
PWPalak Wadhwa
Palak Wadhwa
CCChristopher Cawthorne
Christopher Cawthorne
CTCharalampos Tsoumpas
Charalampos Tsoumpas
KTKris Thielemans
Kris Thielemans
In this paper, we describe the implementation of support for Time-of-Flight (TOF) Positron Emission Tomography (PET) for both listmode and sinogram data in the open source Software for Tomographic Image Reconstruction (STIR). We provide validation and performance characterization using simulated data from the open source GATE Monte Carlo toolbox, with TOF configurations spanning from 81.2 to 209.6 ps. The coincidence detector resolution was corrected for the timing resolution deterioration due to the contribution of the crystal length. Comparison between the reconstruction of listmode and sinogram data demonstrated good agreement in both TOF and non-TOF cases in terms of relative absolute error. To reduce the reconstruction time, we assessed the truncation of the TOF kernel along Lines-of-Response (LOR). Rejection of LOR elements beyond four times the TOF standard deviation provides significant acceleration of ≈45% without compromising the image quality. Further narrowing of the kernel can provide extra time reduction but with the gradual introduction of error in the reconstructed images. As expected, TOF reconstruction performs better than non-TOF in terms of both Contrast-Recovery-Coefficient (CRC) and Signal-to-Noise ratio (SNR). CRC achieves convergence faster with TOF, at lower noise levels. SNR with TOF was superior for early iterations, but with quick deterioration. Higher timing resolution further improved reconstruction performance, while TOF bin mashing was shown to have only a small impact on reconstructed images.