Petar Kolar

Dr. Petar Kolar

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Petar KolarPetar Kolar
Petar Kolar
MGMihael Grbić
Mihael Grbić
SHSilvio Hrabar
Silvio Hrabar
Assurance of high measuring sensitivity is one of the most challenging issues for any nuclear magnetic resonance (NMR) spectroscopy system. To this end, we propose an accurate noise model of the entire probe-to-spectrometer receiving chain for condensed matter physics, based on the concept of noise figure. The model predicts the propagation of both the signal and noise levels in every component of the NMR spectroscopy receiving chain. Furthermore, it enables identification of the "weakest" component and, therefore, the optimization of the whole system. The most important property of the proposed model is the possibility to find system parameters that reduce the measurement time by an a priori calculation, rather than an a posteriori approach. The model was tested experimentally on several different samples. It was found that the measurement time can still be significantly shortened, down to at least one half of the measurement time, starting from optimized conditions with commercially available components. Thus, the proposed model can be used as a tool for both quantitative analysis of the noise properties and a sensitivity prediction of practical NMR systems in physics and material science.

1 September 2020
Verified
Conference Paper
Open access
Petar KolarPetar Kolar
Petar Kolar
FTFilip Turčinović
Filip Turčinović
DBDario Bojanjac
Dario Bojanjac
Due to the COVID-19 pandemic that bursted out this year, online education has become a main type of education and an entire education system was forced to make a switch from classrooms to World Wide Web. The impact of the students receiving education online for the entire semester on their final grade was analysed and the results are shown in the paper. These results are obtained by analysing the academic course Mathematical Analysis 2, held online at the Faculty of Electrical Engineering and Computing, University of Zagreb, Croatia, in the summer semester of 2020. Furthermore, the number of views of the lectures in relation to the time left until the final exam was checked in order to investigate the students’ studying habits. Unsurprisingly, the most noticeable effect here is the last minute cramming. Nevertheless, the overall results show the pros and cons of online education, as well as the huge potential that online education has, even when performed at the current state.

17 April 2021 in TM - Technisches Messen
Verified
Journal Article
Closed access
Petar KolarPetar Kolar
Petar Kolar
LBLovro Blažok
Lovro Blažok
DBDario Bojanjac
Dario Bojanjac
Ever since noise was spotted and proven to cause problems for the transmission and detection of information through a communication channel, a standard procedure in the process of characterizing a detection system of the communication channel is to determine the level of the lowest detectable signal. In signal processing, this is usually done by determining the so-called threshold signal-to-noise ratio (SNR). This determination is especially important for the communication channels and systems that constantly operate with low-level signals. A good example of such a system is definitely the NMR spectroscopy system. However, to the authors’ knowledge, the threshold SNR value of NMR spectroscopy systems has not been determined yet. That is why the experts in the field of NMR spectroscopy were asked to assess, using an online questionnaire, which SNR level they considered to be the NMR threshold SNR level. Afterwards, the threshold value was calculated from the obtained data. Finally, it was compared to the existing rule of thumb and thus, a conclusion about its legitimacy was made. The described questionnaire is still available online (https://forms.gle/Y9hyDZ1v1iJoEbk27). This enables everyone to form their own opinion about the threshold SNR level, which the authors encourage the readers to do.

27 August 2020 in TM - Technisches Messen
Verified
Journal Article
Closed access
PDF file
Petar KolarPetar Kolar
Petar Kolar
LBLovro Blažok
Lovro Blažok
DBDario Bojanjac
Dario Bojanjac
In the last decade or two, it seems that the trend of technological advance in NMR spectroscopy cannot follow the trend of desire to measure NMR samples with gradually lower response signals. Recently, an accurate noise model, based on the concept of noise figure, of the most sensitive part of the NMR spectroscopy system from the aspect of noise, which is its probe-to-spectrometer receiving chain, was introduced. The main purpose of this model is to optimize the used NMR spectroscopy system and, ultimately, enable measuring NMR samples with even lower response signals than the ones measured today. All the parameters of the NMR spectroscopy system, used in the introduced model, can be easily measured using vector network analyzers and noise figure meters, or can be found in the datasheets of the respective elements, except the spectrometer’s receiving chain noise figure. In this contribution, the process of spectrometer’s receiving chain noise figure measurement, performed using the Twice Power Method, is described. A block diagram representation of the spectrometer’s receiving chain is presented here, as well as its approximative model. The respective noise figure measurement results, which are also presented, explain the general tendency of using the mid-range of the spectrometer’s gain control level when performing the actual NMR measurements.

18 March 2022 in Automatika
Verified
Journal Article
Open access
Petar KolarPetar Kolar
Petar Kolar
LBLovro Blažok
Lovro Blažok
DBDario Bojanjac
Dario Bojanjac
One of the challenges in modern nuclear magnetic resonance (NMR) is achieving its highest possible measuring sensitivity. This is because modern NMR samples' response signals decrease, so background noise of the used NMR spectroscopy system causes bigger problems. As a solution, both software and hardware interventions were applied. However, these improvements were obtained experimentally, so the reason for their proper operation and upper limit is usually unknown. Recently, a noise model of the NMR spectroscopy system, which shows both the reason for proper operation and the upper limit of the applied improvements, was introduced. A Javascript-based calculator, based on the introduced model, has been developed and made available online as a user-friendly website that can be run on the most commonly used Internet browsers. To the authors' knowledge, this calculator is the first of its kind that analyses noise properties in NMR. Using it, one can a priori make both sensitivity prediction of practical NMR systems in physics and material science and quantitative analysis of its noise properties. Consequently, overall measurement duration can be shortened down to one half of the current duration. This is an immense improvement, as some modern NMR measurements consume more than ten hours per measurement.

1 July 2014
Verified
Conference Paper
Closed access
SHSilvio Hrabar
Silvio Hrabar
Petar KolarPetar Kolar
Petar Kolar
APAntonija Peric
Antonija Peric
Summary form only given. The phenomenon of extraordinary transmission was firstly demonstrated at optical frequencies (D. E. Grupp, H. J. Lezec, T. Thio, and T. W. Ebbesen, Beyond the Bethe limit: Tunable enhanced light transmission through a single wavelength aperture, Advanced Mater., vol. 11, pp. 860-862, 1999), and later also explained by using theory of leaky waves. In the metamaterial community, it has been proposed to achieve this extraordinary transmission by use of the ENZ (or MNZ) fillings either in the aperture or as the aperture cover (A. Alù, F. Bilotti, N. Engheta, and L. Vegni, Metamaterial covers over a small aperture, IEEE Transactions on Antennas and Propagation, vol. 54, no. 6, pp. 1632-1643, June 2006). Unfortunately, all passive ENZ and MNZ materials (as well as the ENG, and MNG materials) suffer from inherent narrow operating bandwidth caused by basic energy-dispersion constraints. Recently, it has been shown possible to build ultra-broadband (bandwidth up to six octaves) active ENZ metamaterials that overcome fundamental dispersion constraints. These metamaterials are based on non-Foster negative capacitors (S. Hrabar, I. Krois, et al., Negative capacitor paves the way to ultra-broadband metamaterials', Applied physics letters. Vol. 99, No. 25, 25403-1-25403-4, December 2011).Here, we show both numerically and experimentally that is possible to use very similar concept for broadband extraordinary transmission through the subwavelength aperture. The demonstrator comprises a simple air-filled microstrip line with a blocking metallic screen and it operates in 100 MHz RF band. The microstrip line is laid through the rectangular (subwaveleght) screen aperture. The aperture 'filling' is a short monopole antenna loaded with a opamp based negative capacitor previously developed in our group (Muha, D., Hrabar, S., Krois, I.; Bonic, I. Kiricenko, A., Zaluski, D., Design of UHF Microstrip Non-Foster Leaky-wave Antenna, Proc. on ICECOM 2013., pp. 134138, Dubrovnik, 2013). It was envisaged that this simple inclusion should cause broadband ENZ effect, and therefore should yield broadband transmission enhancement (tunneling). As a first step, the full-wave simulations, complemented by time-domain SPICEbased stability analysis of a measurement setup were performed. These simulations predicted a stable enhancement of 4-5 dB within one octave bandwidth (70-140 MHz). This bandwidth is considerably wider than a 5 % wide (95-100 MHz) bandwidth, predicted for the case of an ordinary resonant ENZ inclusion (a short monopole loaded with an inductor). Manufacturing of the RF demonstrator is in progress and the preliminary experimental results will be presented at the conference.