Sabine Bauer

Dr. Sabine Bauer

University of Koblenz and Landau, Mainz, Rhineland-Palatinate, Germany
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2020 in IEEE Transactions on Visualization and Computer Graphics
Verified
Journal Article
Closed access
PEPepe Eulzer
Pepe Eulzer
Sabine BauerSabine Bauer
Sabine Bauer
FKFrancis Kilian
Francis Kilian
KLKai Lawonn
Kai Lawonn
We propose a visualization application, designed for the exploration of human spine simulation data. Our goal is to support research in biomechanical spine simulation and advance efforts to implement simulation-backed analysis in surgical applications. Biomechanical simulation is a state-of-the-art technique for analyzing load distributions of spinal structures. Through the inclusion of patient-specific data, such simulations may facilitate personalized treatment and customized surgical interventions. Difficulties in spine modelling and simulation can be partly attributed to poor result representation, which may also be a hindrance when introducing such techniques into a clinical environment. Comparisons of measurements across multiple similar anatomical structures and the integration of temporal data make commonly available diagrams and charts insufficient for an intuitive and systematic display of results. Therefore, we facilitate methods such as multiple coordinated views, abstraction and focus and context to display simulation outcomes in a dedicated tool. By linking the result data with patient-specific anatomy, we make relevant parameters tangible for clinicians. Furthermore, we introduce new concepts to show the directions of impact force vectors, which were not accessible before. We integrated our toolset into a spine segmentation and simulation pipeline and evaluated our methods with both surgeons and biomechanical researchers. When comparing our methods against standard representations that are currently in use, we found increases in accuracy and speed in data exploration tasks. In a qualitative review, domain experts deemed the tool highly useful when dealing with simulation result data, which typically combines time-dependent patient movement and the resulting force distributions on spinal structures.

6 January 2012 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
Sabine BauerSabine Bauer
Sabine Bauer
UHU. Hausen
U. Hausen
KGK. Gruber
K. Gruber
Article Effects of individual spine curvatures – a comparative study with the help of computer modelling was published on September 6, 2012 in the journal Biomedical Engineering / Biomedizinische Technik (volume 57, issue SI-1-Track-O).

3 April 2023 in Biomechanics
Verified
Journal Article
Open access
PDF file
IKIvanna Kramer
Ivanna Kramer
Sabine BauerSabine Bauer
Sabine Bauer
VKValentin Keppler
Valentin Keppler
In many fields of spinal health care, efforts have been made to offer individualized products and therapy tailored to the patient. Therefore, the prevailing alignment of the spine must be considered, which varies from person to person and depends on the movement and loading situation. With the help of patient-specific simulation models of the spine, the geometrical parameters in a specific body position can be analyzed, and the load situation of the spinal structures during dynamic processes can be assessed. However, to enable the future usability of such simulation models in medical reality, as many patient-specific conditions as possible need to be considered. Another critical requirement is that simulation models must be quickly and easily created for use in clinical routine. Building new or adapting existing spine multibody simulation (MBS) models is time-consuming due to their complex structure. To overcome this limitation, we developed a simple, efficient method by which to automatically adjust the lumbar curvature orientation of the spine model. The method extracts a new 3D lordosis curve from patient-specific data in the preprocessing step. Then the vertebrae and all linked spinal structures of an existing spinal simulation model are transformed so that the lumbar lordosis follows the curve obtained in the first part of the method. To validate the proposed approach, three independent experts measured the Cobb angle in the source and the generated spine alignments. We calculated a mean absolute error of 1.29° between the generated samples and the corresponded ground truth. Furthermore, the minor deviation in the root mean square error (RMSE) of 0.0012 m2 between the areas under the alignment curves in the original and target lordosis curvatures indicated the accuracy of the proposed method. The proposed method demonstrated that a new patient-specific simulation model can be generated in a short time from any suitable data source.

24 August 2016
Verified
Book Chapter
Open access
PDF file
Sabine BauerSabine Bauer
Sabine Bauer
Basics of Multibody Systems: Presented by Practical Simulation Examples of Spine Models | InTechOpen, Published on: 2016-08-24. Authors: Bauer Sabine

27 September 2017
Verified
Book Chapter
Open access
PDF file
Sabine BauerSabine Bauer
Sabine Bauer
PDPaulus Dietrich
Paulus Dietrich
Statistical analyses show that both the spine curvature and the morphological properties of the vertebral bodies can differ considerably. Therefore, the best outcome of a surgery for the individual patient could be achieved by developing patient specific implants to prevent inadequate anchorage of implants that don?t optimally fit to the anatomy and can cause damages of spinal structures.

8 June 2021
Verified
Book Chapter
Open access
PDF file
Sabine BauerSabine Bauer
Sabine Bauer
IKIvanna Kramer
Ivanna Kramer
The knowledge about the impact of structure-specific parameters on the biomechanical behavior of a computer model has an essential meaning for the realistic modeling and system improving. Especially the biomechanical parameters of the intervertebral discs, the ligamentous structures and the facet joints are seen in the literature as significant components of a spine model, which define the quality of the model. Therefore, it is important to understand how the variations of input parameters for these components affect the entire model and its individual structures. Sensitivity analysis can be used to gain the required knowledge about the correlation of the input and output variables in a complex spinal model. The present study analyses the influence of the biomechanical parameters of the intervertebral disc using different sensitivity analysis methods to optimize the spine model parameters. The analysis is performed with a multi-body simulation model of the cervical functional spinal unit C6-C7.