Sarranya Banerjee

Dr. Sarranya Banerjee

Department of Civil Engineering, Indian Institute of Technology Bombay, Mumbai, Mahārāshtra, International
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2022 in Structural Control and Health Monitoring
Verified
Journal Article
Closed access
Sarranya BanerjeeSarranya Banerjee
Sarranya Banerjee
AGAparna (Dey) Ghosh
Aparna (Dey) Ghosh
Vasant Annasaheb MatsagarVasant Annasaheb Matsagar
Vasant Annasaheb Matsagar

6 July 2023 in Buildings
Verified
Journal Article
Open access
PDF file
Sarranya BanerjeeSarranya Banerjee
Sarranya Banerjee
Vasant Annasaheb MatsagarVasant Annasaheb Matsagar
Vasant Annasaheb Matsagar
Lifeline structures such as hospital buildings need to be specifically designed such that they experience reduced vibrations when subjected to earthquake excitations because it will be difficult to vacate hospital buildings under the event of any earthquake. Therefore, to ensure operational condition under earthquake excitations in an existing hospital building, the present study utilizes flexible unbonded fiber-reinforced elastomeric isolators (UFREIs) for its seismic isolation. The UFREI-based isolation system is designed to restrict the structural acceleration within the tolerable limits for the building inhabitants even during earthquake hazards. However, the use of such flexible isolators results in excessively large bearing displacements, which either may not be practical and/or pose several serviceability issues. Therefore, tuned mass damper (TMD) is attached to the base floor of the UFREI-isolated hospital building to reduce the large isolator displacements. Properties of the hybrid vibration control system are designed according to the site-specific scenario in New Delhi, India. Further, nonlinear time-history analyses of the UFREI-isolated hospital building with the TMD are carried out, and responses are compared with its uncontrolled response. Results show that the peak bearing displacement response of the UFREI-isolated hospital building is reduced by 9% to 27%, due to the addition of the TMD. Importantly, the required design displacement of the UFREI-based isolation system is decreased by 27%, without compromising the effectiveness of base isolation. In fact, the performance of the hybrid vibration control system is superior to the base isolation system alone.

1 April 2024 in Soil Dynamics and Earthquake Engineering
Verified
Journal Article
Closed access
Sarranya BanerjeeSarranya Banerjee
Sarranya Banerjee
TSTaiki Saito
Taiki Saito
Vasant Annasaheb MatsagarVasant Annasaheb Matsagar
Vasant Annasaheb Matsagar

1 September 2020 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
Sarranya BanerjeeSarranya Banerjee
Sarranya Banerjee
AGAparna (Dey) Ghosh
Aparna (Dey) Ghosh
The tuned mass damper (TMD) is a well-established vibration control device that has been implemented in several structures worldwide. The performance of passive TMD is greatly dependent on its design parameters. A key issue for the design of the optimal TMD is the identification of the parameters of the structure to which the TMD is to be attached. Here, it is important also to consider the perturbations that may arise in the structural frequency due to different practical issues. The present work focusses on this and aims to obtain the optimum TMD parameters in a Genetic Algorithm (GA) framework. The results of the proposed optimal strategy, in terms of optimal tuning ratio and optimal damping ratio, for a given value of the mass ratio, are compared with some of the existing optimal solutions for linear TMD under base excitation. The effectiveness of all these optimally designed TMDs in reducing the structural response is further demonstrated when the structure-TMD system is subjected to recorded earthquake ground motions. It is seen that in the tuned condition, the control performance obtained by the different designs of the TMD are similar to each other, although having some minor differences in the values of the optimum parameters. Also, the effectiveness of the different TMD designs in the detuned condition is investigated, in which the present design technique is found to be the most effective.

17 September 2020 in Journal of Structural Integrity and Maintenance
Verified
Journal Article
Closed access
Sarranya BanerjeeSarranya Banerjee
Sarranya Banerjee
AGAparna (Dey) Ghosh
Aparna (Dey) Ghosh
This paper presents an optimal design procedure for a nonlinear TMD with Bingham-type damping that can lead to a more economic and realistic design of the damper. The optimization problem is solved in the Genetic Algorithm (GA) framework. Considering small nonlinearities, the nonlinear TMD design using GA is validated through standard equivalent linearization method. The efficacy of the TMD designs is presented through a numerical simulation study on four different single-degree-of-freedom structure-TMD systems subjected to recorded earthquake ground motions. Results indicate that the optimally designed nonlinear TMD with Bingham-type damping can effectively reduce the size of the TMD damping element at the cost of a very slight degradation in control performance as compared to the linear TMD. The improved performance of the nonlinear TMD with Bingham-type damping over the linear TMD that develops post-design nonlinearities is also shown. Further, a robust design procedure of the nonlinear TMD using GA is presented that can cater to perturbations in the natural frequency of the primary structure. Thus, the optimal design procedure using GA for the nonlinear TMD offers several advantages as compared to the statistical linearization approach.

1 March 2025 in ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems, Part A: Civil Engineering
Verified
Journal Article
Closed access
Sarranya BanerjeeSarranya Banerjee
Sarranya Banerjee
TSTaiki Saito
Taiki Saito
Vasant Annasaheb MatsagarVasant Annasaheb Matsagar
Vasant Annasaheb Matsagar