Stanislav Štuhec

Mr. Stanislav Štuhec

Faculty for sport, Ljubljana, Slovenia

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MČMilan Čoh
Milan Čoh
Nejc BončinaNejc Bončina
Nejc Bončina
SŠStanislav Štuhec
Stanislav Štuhec
Krzysztof MackalaKrzysztof Mackala
Krzysztof Mackala
The purpose of the study was to compare the biomechanical parameters of the hurdle clearance technique of the fifth hurdle in the 110 m hurdle race of Colin Jackson of Great Britain (12.91 s world record was set in 1994) and Dayron Robles of Cuba (12.87 s world record was set in 2008), two world record holders. Despite the athletes having performed at different times, we used comparable biomechanical diagnostic technology for both hurdlers. Biomechanical measurements for both were performed by the Laboratory for Movement Control of the Institute of Sport, Faculty of Sport in Ljubljana. A three-dimensional video analysis of the fifth hurdle clearance technique was used. High standards of biomechanical measurements were taken into account, thus ensuring the high objectivity of the obtained results. The following program was used: the ARIEL kinematic program (Ariel Dynamics Inc., Trabuco Canyon, CA, USA). The results of the comparative analysis found minimal differences between the two athletes, which was expected given their excellence. Dayron Robles’s hurdle clearance was more effective, as it was characterized by a smaller loss of horizontal center of mass (COM) velocity. Robles’s hurdle clearance took 0.50 s: 0.10 s for the take-off, 0.33 s for the flight phase, and 0.07 s for the landing phase. Colin Jackson completed the hurdle clearance slightly slower, as it took him 0.54 s. Jackson’s take-off phase also lasted 0.10 s, his flight phase 0.36 s, and his landing 0.08 s. The two athletes are quite different in their morphological constitution. Dayron Robles is 10 cm taller than Colin Jackson, resulting in a lower flight parabola of CM during hurdle clearance of the Cuban athlete. Dayron Robles has a more effective hurdle clearance technique compared to Jackson’s achievement. It can be considered that their individual techniques of overcoming the hurdle, reached their individual highest efficiency at this time.

26 October 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
SŠStanislav Štuhec
Stanislav Štuhec
PPPeter Planjšek
Peter Planjšek
MČMilan Čoh
Milan Čoh
Krzysztof MackalaKrzysztof Mackala
Krzysztof Mackala
The purpose of this report is to provide additional analysis and commentary on the men’s 100 m world record of 9.58 s, set by Usain Bolt in the 2009 Berlin World Championships in Athletics. In addition, the entire race underwent a unique kinematic analysis, particularly emphasizing the maximum running velocity and its related factors. It was possible due the application of the new Stuhec software. The data were provided by LAVEG’S advanced laser measurement technology based on positional data with a high spatiotemporal resolution. The maximum velocity phase is the most critical determinant of the final race time. Bolt completed two phases in this world-record 100 m sprint: acceleration and top velocity. The borderline between these phases reached the highest velocity of 12.32 m/s on a 52 m run. He could keep the maximum velocity in five 10 m sections (50–100 m). The occurrence of functional asymmetry—the difference in step length between the left and right legs—was also noticed. Longer steps were taken with the left leg, almost over 80 m. From a practical point of view, new technologies (e.g., software) allow coaches and athletes to analyze the kinematic parameters of sprinting even more precisely and in detail. They must take into account precise changes in the course of maximum speed and the parameters determining it which are step length and frequency. Based on such an analysis, it is possible to modify the training process aimed at increasing the potential, both maximum speed and the supporting factors of strength and power. This must be conditioned by the appropriate selection of training measures shaping the abovementioned motor skills and parameters describing the optimal sprinting technique.

5 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SŠStanislav Štuhec
Stanislav Štuhec
PPPeter Planjšek
Peter Planjšek
Mariusz PtakMariusz Ptak
Mariusz Ptak
MČMilan Čoh
Milan Čoh
Krzysztof MackalaKrzysztof Mackala
Krzysztof Mackala
The industrial development of technology, with appropriate adaptation, enables us to discover possibilities in sport training control. Therefore, we have developed a new approach to linear running analysis. This study aims to determine the measurement possibilities using an LDM301A laser system in obtaining basic kinematic parameters. The second goal is the application of specialized computer programs based on appropriate algorithms to calculate a vast number of variables that can be used to adjust the training and the rivalry. It is a non-invasive, non-contact measurement method. We can also determine the influence of both subjective and objective external factors. In this way, we can also conduct training with real-time scientific feedback. This method is easy to use and requires very little time to set up and use. The efficiency and running economy can be calculated with various time, speed, acceleration, and length indexes. Calculating the symmetries between the left and right leg in velocity, stride lengths, support phase times, flight phase times, and step frequency are possible. Using the laser measurement method and detailed kinematic analysis may constitute a new chapter in measuring speed. However, it still has to compete with classic photocell measurement methods. This is mainly due to their high frequency of measurement used, despite some reservations about the scale of measurement errors.

17 September 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SŠStanislav Štuhec
Stanislav Štuhec
TRTina Robnik
Tina Robnik
Mateusz JopekMateusz Jopek
Mateusz Jopek
Krzysztof MackalaKrzysztof Mackala
Krzysztof Mackala
Return-to-play (RTP) decisions after severe knee injury in elite athletes remain challenging because functional recovery may not coincide with physiological tissue recovery. This longitudinal case report evaluated Advanced 19-Frequency Bioelectrical Impedance Vector Analysis (A19FBIVA) as a non-invasive sensor-based approach for monitoring segmental lower-limb bioelectrical changes in an elite female alpine skier following a complex right knee injury. Segmental resistance (R), reactance (Xc), phase angle (PhA), and inter-limb asymmetry were assessed with a Seca mBCA 515 analyzer at 19 frequencies (1–1000 kHz) at four time points: 5 days pre-injury, 26 days post-injury, 64 days post-injury, and 135 days post-injury. The rare pre-injury baseline enabled individualized comparison beyond contralateral symmetry. At the final late-stage rehabilitation follow-up, R in the injured lower-limb segment had normalized or improved, whereas Xc and PhA remained suppressed, indicating an observational bioelectrical pattern consistent with persistent capacitance-related impairment rather than direct evidence of localized knee-tissue healing. The uninjured limb also deteriorated during early rehabilitation, demonstrating that contralateral comparison alone may underestimate residual deficits. These findings support the exploratory concept of a ‘reactance lag’ and indicate that A19FBIVA may provide a useful complementary monitoring layer, alongside clinical examination, imaging, functional testing, and sport-specific assessment. Larger prospective studies are required to validate thresholds, reliability, and prognostic value.