A carbon fiber-reinforced polymer (CFRP) is a common material utilized for the enhancement in reinforced concrete (RC) constructions. Previous research indicates that the bonding performance between a CFRP sheet and concrete determines whether the bonding of CFRP material is effective. However, the majority of existing research on the bonding performance of the CFRP–concrete interface is concentrated on static loading conditions. In order to clarify the effect of dynamic load on the bonding performance of the CFRP sheet–concrete interface, this study adopts the double-sided shear test method to carry out dynamic experimental research. The test findings reveal that the damage pattern of the CFRP sheet–concrete interface remains consistent across different loading rates. The ultimate bearing capacity increases as the strain rate increases. As the strain rate increases from 10−5 s−1 to 10−2 s−1, the effect of bond length on ultimate bearing capacity increases by about 7%. As the strain rate increases, both the maximum strain of CFRP and the maximum interfacial shear stress demonstrate a corresponding increase, with respective increase rates of 60% and 20%. The effective bond length decreases by about 20% when the strain rate rises from 10−5 s−1 to 10−2 s−1. Finally, a formula for calculating the dynamic effective bond length of a CFRP sheet, grounded in the Chen and Teng formula, has been proposed and verified.
In practical engineering, buildings are predominantly subjected to combined forces, and reinforced concrete (RC) beams serve as the primary load-bearing components of buildings. However, there is a paucity of research on the torsional effects of RC beams, particularly concerning the torsional failure mechanisms of large-size beams. To address this gap, this paper establishes a meso-scale numerical analysis model for RC beams reinforced with Carbon Fiber Reinforced Polymer (CFRP) sheets under combined bending and torsion pressures. The research analyzes how the fiber ratio and torsion-bending ratio govern torsion-induced failure characteristics and size effects in CFRP-strengthened RC beams. The results indicate that an increase in the fiber ratio leads to accumulated damage distribution in the RC beam, a gradual decrease in CFRP sheet strain, and an increase in peak load and peak torque, albeit with diminishing amplitudes; as the torsion-bending ratio increases, crack distribution becomes more concentrated, the angle between cracks and the horizontal direction decreases, overall peak load decreases, peak torque increases, and CFRP sheet strain increases; and the nominal torsional capacity of CFRP-strengthened RC beams declines with increasing size, exhibiting a reduction of 24.1% to 35.6%, which distinctly demonstrates the torsional size effect under bending–torsion coupling conditions. A modified Torque Size Effect Law is formulated, characterizing in quantitative terms the dependence of the fiber ratio and the torsion-bending ratio.
24 January 2026 in Journal of Building Engineering
A three-dimensional meso-scale numerical model, which considers (1) the concrete meso-structures, (2) the bond slip between concrete internal structures and steel bars, and (3) the stripping behavior of carbon fiber reinforced polymer (CFRP) cloth from the surface of the concrete component, is established to investigate the effects of concrete strength and the CFRP cloth ratio on the shear performance of reinforced concrete (RC) beams. On the basis of verifying the rationality of the shear failure model and the feasibility of the CFRP reinforcement simulation method, 30 orthogonally designed numerical models of six kinds of concrete strength and five kinds of CFRP cloth ratios were designed and established. Based on the numerical simulation results, this paper analyzes the damage evolution of the CFRP–concrete interface, the variation trend of CFRP strain along the height direction of beam, the failure mode, and the load-displacement curve. Results show the following: (1) With the increase of concrete strength grade and CFRP cloth ratio, the shear strength of RC beams strengthened with increases in CFRP cloth ratio, the influence range of concrete strength grade is 24–50%, and the influence range of the CFRP cloth ratio is 10–25%; (2) The improvement range decreases, and the improvement range of the concrete strength grade decreases, and the reduction range is about 20%; (3) Based on the simulation results, influences of concrete strength and CFRP cloth ratio on the shear strength of CFRP cloth-strengthened RC beams are quantitatively considered.
The combined application of Carbon Fiber Reinforced Polymer (CFRP) and recycled aggregate concrete is of great importance in conserving resources and reducing environmental pollution. A dynamic experimental study was conducted using a double-sided shear test method, and the bonding behavior of CFRP sheet-recycled aggregate concrete interface was analyzed. The effects of seven kinds of bond length, four kinds of bond width and three kinds of load rate on the interface properties were considered. The experimental results demonstrate that: 1) The main damage pattern of the CFRP sheet-recycled aggregate concrete interface is stripping damage of concrete surfaces. 2) As the bond length and bond width increase, the ultimate bearing capacity of the CFRP sheet-recycled aggregate concrete interface increases, and the influence of loading rate on the ultimate bearing capacity decreases. 3) It is evident that the interfacial fracture energy and interfacial shear stress are subject to a pronounced strain rate effect. In the bond-slip relationship of the interface, a reduction in bond width and an increase in loading rate result in an increase in the slip corresponding to the peak shear stress.