Andrea Merlo

Dr. Andrea Merlo

Azienda USL-IRCCS di Reggio Emilia, Reggio Emilia, Emilia-Romagna, Italy
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2011 in Clinical Biomechanics
Verified
Journal Article
Closed access
Alberto LeardiniAlberto Leardini
Alberto Leardini
FBFabio Biagi
Fabio Biagi
AMAndrea Merlo
Andrea Merlo
CBClaudio Belvedere
Claudio Belvedere
MBMaria Grazia Benedetti
Maria Grazia Benedetti

20 March 2003 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
AMAndrea Merlo
Andrea Merlo
DFD. Farina
D. Farina
RMR. Merletti
R. Merletti
The estimation of on-off timing of human skeletal muscles during movement is an important issue in surface electromyography (EMG) signal processing with relevant clinical applications. In this paper, a novel approach to address this issue is proposed. The method is based on the identification of single motor unit action potentials from the surface EMG signal with the use of the continuous wavelet transform. A manifestation variable is computed as the maximum of the outputs of a bank of matched filters at different scales. A threshold is applied to the manifestation variable to detect EMG activity. A model, based on the physical structure of the muscle, is used to test the proposed technique on synthetic signals with known features. The resultant bias of the onset estimate is lower than 40 ms and the standard deviation lower than 30 ms in case of additive colored Gaussian noise with signal-to-noise ratio as low as 2 dB. Comparison with previously developed methods was performed, and representative applications to experimental signals are presented. The method is designed for a complete real-time implementation and, thus, may be applied in clinical routine activity.

1 September 2012 in Gait & Posture
Verified
Journal Article
Closed access
AMAndrea Merlo
Andrea Merlo
DZDamiano Zemp
Damiano Zemp
EZEnrica Zanda
Enrica Zanda
SRSabrina Rocchi
Sabrina Rocchi
FMFabiano Meroni
Fabiano Meroni
PQPierluigi Quadri
Pierluigi Quadri

1 June 2013 in Gait & Posture
Verified
Journal Article
Closed access
ICIsabella Campanini
Isabella Campanini
AMAndrea Merlo
Andrea Merlo
BDB. Damiano
B. Damiano

1 August 2007 in Journal of Electromyography and Kinesiology
Verified
Journal Article
Closed access
ICIsabella Campanini
Isabella Campanini
AMAndrea Merlo
Andrea Merlo
PDP. Degola
P. Degola
RMR. Merletti
R. Merletti
GVG. Vezzosi
G. Vezzosi
DFD. Farina
D. Farina

13 July 2014 in BioMed Research International
Verified
Journal Article
Open access
PDF file
Marco IosaMarco Iosa
Marco Iosa
ACA. Cereatti
A. Cereatti
AMAndrea Merlo
Andrea Merlo
ICIsabella Campanini
Isabella Campanini
SPStefano Paolucci
Stefano Paolucci
ACA. Cappozzo
A. Cappozzo
The assessment of waveform similarity is a crucial issue in gait analysis for the comparison of kinematic or kinetic patterns with reference data. A typical scenario is in fact the comparison of a patient’s gait pattern with a relevant physiological pattern. This study aims to propose and validate a simple method for the assessment of waveform similarity in terms of shape, amplitude, and offset. The method relies on the interpretation of these three parameters, obtained through a linear fit applied to the two data sets under comparison plotted one against the other after time normalization. The validity of this linear fit method was tested in terms of appropriateness (comparing real gait data of 34 patients with cerebrovascular accident with those of 15 healthy subjects), reliability, sensitivity, and specificity (applying a cluster analysis on the real data). Results showed for this method good appropriateness, 94.1% of sensitivity, 93.3% of specificity, and good reliability. The LFM resulted in a simple method suitable for analysing the waveform similarity in clinical gait analysis.