Yi-Pin Chen

Dr. Yi-Pin Chen

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2020 in Electronics
Verified
Journal Article
Open access
PDF file
CCChiao-Fan Chiu
Chiao-Fan Chiu
SGSreekanth Ginnaram
Sreekanth Ginnaram
ASAsim Senapati
Asim Senapati
YCYi-Pin Chen
Yi-Pin Chen
SMSiddheswar Maikap
Siddheswar Maikap
Resistive switching characteristics by using the Al2O3 interfacial layer in an Al/Cu/GdOx/Al2O3/TiN memristor have been enhanced as compared to the Al/Cu/GdOx/TiN structure owing to the insertion of Al2O3 layer for the first time. Polycrystalline grain, chemical composition, and surface roughness of defective GdOx film have been investigated by transmission electron microscope (TEM), X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD), and atomic force microscopy (AFM). For bipolar resistive switching (BRS) characteristics, the conduction mechanism of high resistance state (HRS) is a space-charge limited current for the Al/Cu/GdOx/TiN device while the Al/Cu/GdOx/Al2O3/TiN device shows Schottky emission. However, both devices show Ohmic at a low resistance state (LRS). After the device has been SET, the Cu filament evidences by both TEM and elemental mapping. Oxygen-rich at the Cu/GdOx interface and Al2O3 layer are confirmed by energy dispersive X-ray spectroscopy (EDS) line profile. The Al/Cu/GdOx/Al2O3/TiN memristor has lower RESET current, higher speed operation of 100 ns, long read pulse endurance of >109 cycles, good data retention, and the memristor with a large resistance ratio of >105 is operated at a low current of 1.5 µA. The complementary resistive switching (CRS) characteristics of the Al/Cu/GdOx/Al2O3/TiN memristor show also a low current operation as compared to the Al/Cu/GdOx/TiN device (300 µA vs. 3.1 mA). The transport mechanism is the Cu ion migration and it shows Ohmic at low field and hopping at high field regions. A larger hopping distance of 1.82 nm at the Cu/GdOx interface is obtained as compared to a hopping distance of 1.14 nm in the Al2O3 layer owing to a larger Cu filament length at the Cu/GdOx interface than the Al2O3 layer. Similarly, the CRS mechanism is explained by using the schematic model. The CRS characteristics show a stable state with long endurance of >1000 cycles at a pulse width of 1 µs owing to the insertion of Al2O3 interfacial layer in the Al/Cu/GdOx/Al2O3/TiN structure.

12 June 2024 in Polymers
Verified
Journal Article
Open access
PDF file
YCYi-Pin Chen
Yi-Pin Chen
TLTsia-Shu Lo
Tsia-Shu Lo
CYChien Yuhan
Chien Yuhan
YKYi-Hua Kuo
Yi-Hua Kuo
Shih-Jung LiuShih-Jung Liu
Shih-Jung Liu
Pelvic prolapse stands as a substantial medical concern, notably impacting a significant segment of the population, predominantly women. This condition, characterized by the descent of pelvic organs, such as the uterus, bladder, or rectum, from their normal positions, can lead to a range of distressing symptoms, including pelvic pressure, urinary incontinence, and discomfort during intercourse. Clinical challenges abound in the treatment landscape of pelvic prolapse, stemming from its multifactorial etiology and the diverse array of symptoms experienced by affected individuals. Current treatment options, while offering relief to some extent, often fall short in addressing the full spectrum of symptoms and may pose risks of complications or recurrence. Consequently, there exists a palpable need for innovative solutions that can provide more effective, durable, and patient-tailored interventions for pelvic prolapse. We manufactured an integrated polycaprolactone (PCL) mesh, reinforced with nano-hydroxyapatite (nHA), along with drug-eluting poly(lactic-co-glycolic acid) (PLGA) nanofibers for a prolapse scaffold. This aims to offer a promising avenue for enhanced treatment outcomes and improved quality of life for individuals grappling with pelvic prolapse. Solution extrusion additive manufacturing and electrospinning methods were utilized to prepare the nHA filled PCL mesh and drug-incorporated PLGA nanofibers, respectively. The pharmaceuticals employed included metronidazole, ketorolac, bleomycin, and estrone. Properties of fabricated resorbable scaffolds were assessed. The in vitro release characteristics of various pharmaceuticals from the meshes/nanofibers were evaluated. Furthermore, the in vivo drug elution pattern was also estimated on a rat model. The empirical data show that nHA reinforced PCL mesh exhibited superior mechanical strength to virgin PCL mesh. Electrospun resorbable nanofibers possessed diameters ranging from 85 to 540 nm, and released effective metronidazole, ketorolac, bleomycin, and estradiol, respectively, for 9, 30, 3, and over 30 days in vitro. Further, the mesh/nanofiber scaffolds also liberated high drug levels at the target site for more than 28 days in vivo, while the drug concentrations in blood remained low. This discovery suggests that resorbable scaffold can serve as a viable option for treating female pelvic organ prolapse.

23 August 2024 in Food Hydrocolloids
Verified
Journal Article
Open access
SWShang-Ta Wang
Shang-Ta Wang
PHPo-Jou Huang
Po-Jou Huang
SCSzu-Kai Chen
Szu-Kai Chen
CSChia-Rui Shen
Chia-Rui Shen
YCYi-Pin Chen
Yi-Pin Chen
Min-Lang TsaiMin-Lang Tsai
Min-Lang Tsai

17 December 2021 in Electronics
Verified
Journal Article
Open access
PDF file
YCYi-Pin Chen
Yi-Pin Chen
ARAnisha Roy
Anisha Roy
PWPing-Hsuan Wu
Ping-Hsuan Wu
SHShih-Yin Huang
Shih-Yin Huang
SMSiddheswar Maikap
Siddheswar Maikap
Dopamine detection by using N2/O2 annealing in a Pt/Ti/n-Si structure is investigated for the first time. To achieve repeatable and stable dopamine detection, a Pt membrane is annealed at elevated temperatures of 500 to 700 °C. N2/O2 gas ambient is used to optimize the membrane. The Pt membrane with thicknesses from 5 to 2 nm is optimized. Novel Pt/Ti/n-Si Schottky contact in a metal–electrolyte–membrane–silicon (MEMS) structure detects dopamine with a low concentration of 1 pM. The Pt membrane with N2 ambient annealing shows the lowest concentration of dopamine sensing with a small volume of 10 µL, acceptable stability, and repeatability. Scan rate-dependent dopamine concentration sensing is also investigated in the two-terminal measurement method. This study is useful for the early diagnosis of Parkinson’s disease in the near future.

1 January 2021 in Journal of Minimally Invasive Gynecology
Verified
Journal Article
Closed access
TLTsia-Shu Lo
Tsia-Shu Lo
KNKai Lyn Ng
Kai Lyn Ng
THTing-Xuan Huang
Ting-Xuan Huang
YCYi-Pin Chen
Yi-Pin Chen
YLYi-Hao Lin
Yi-Hao Lin
WHWu-Chiao Hsieh
Wu-Chiao Hsieh