Static monitors for assessing the fluid status during major surgeries and in critically ill patients have been gradually replaced by more accurate dynamic monitors in modern-day anaesthesia practice. Pulse pressure variation (PPV) and systolic pressure variation (SPV) are the two commonly used dynamic indices for assessing fluid responsiveness. In this prospective observational study, 50 patients undergoing major surgeries were monitored for PPV and SPV: after the induction of anaesthesia and after the administration of 500 mL of isotonic crystalloid bolus. Following the fluid bolus, patients with a cardiac output increase of more than 15% were classified as responders and those with an increase of less than 15% were classified as non-responders. There were no significant differences in the heart rate (HR), mean arterial pressure (MAP), PPV, SVV, central venous pressure (CVP) and cardiac index (CI) between responders and non-responders. Before fluid bolus, the stroke volume was significantly lower in responders (p=0.030). After fluid bolus, MAP was significantly higher in responders but there were no significant changes in HR, CVP, CI, PPV and SVV. In both responders and non-responders, PPV strongly correlated with SVV before and after fluid bolus. Both PPV and SVV are useful to predict cardiac response to fluid loading. In both responders and non-responders, PPV has a greater association with fluid responsiveness than SVV.
Recently, there has been a trend favouring the use of supraglottic airway devices over endotracheal tubes (ETT) during short surgical procedures. In this study, we are going to assess the suitability of one such supraglottic airway device, i-gel, for pressure-controlled ventilation (PCV) during routine surgical procedures. The airway management for 60 patients was done with either i-gel (Group I) or cuffed tracheal tube (Group E) for this prospective, randomised, double-blinded study. Insertion time, number of attempts, ease of insertion and haemodynamic monitoring were recorded before, during and after insertion of these devices. Airway leak tests, leak volume and leak fraction were measured at 15, 20 and 25 cm H2O PCV, and pharyngolaryngeal morbidity was evaluated postoperatively. I-gel is easier to insert than a tracheal tube (p=0.0056). The increase in heart rate and MAP was higher following insertion of tracheal tube in the first few minutes (p<0.001) and subsequently became comparable between the two groups. The leak volume and leak fraction between the two groups were comparable at 15 cm H2O PCV, but significant difference was seen at 20 and 25 H2O PCV between the two groups (p=0.232, p<0.001, p<0.001). Thirty minutes later, the leak volume and leak fraction between groups were comparable at 15 cm H2O PCV (p=0.495, p=0.104) but not at 20 and 25 H2O PCV (p<0.001, p<0.001). Pharyngolaryngeal morbidity was significantly lesser in the i-gel group. I-gel provides a reasonable alternative to cuffed ETT for pressure-controlled ventilation provided the pressures can be limited to 15 to 20 cm H2O.
1 April 2019 in Medical Journal Armed Forces India