The online and continuous measurement of velocity, concentration and mass flow rate of pneumatically conveyed solid particles for the high-efficiency utilization of energy and raw materials has become increasingly significant. In this paper, an integrated instrumentation system for the velocity, concentration and mass flow rate measurement of dense phase pneumatically conveyed solid particles based on electrostatic and capacitance sensorsis developed. The electrostatic sensors are used for particle mean velocity measurement in combination with the cross-correlation technique, while the capacitance sensor with helical surface-plate electrodes, which has relatively homogeneous sensitivity distribution, is employed for the measurement of particle concentration and its capacitance is measured by an electrostatic-immune AC-based circuit. The solid mass flow rate can be further calculated from the measured velocity and concentration. The developed instrumentation system for velocity and concentration measurement is verified and calibrated on a pulley rig and through static experiments, respectively. Finally the system is evaluated with glass beads on a gravity-fed rig. The experimental results demonstrate that the system is capable of the accurate solid mass flow rate measurement, and the relative error is within −3%–8% for glass bead mass flow rates ranging from 0.13 kg/s to 0.9 kg/s.
The deflectometry provides a powerful metrological technique enabling the high-precision testing of reflective surfaces with high dynamic range, such as aspheric and freeform surfaces. In the fringe-illumination deflectometry based on reverse-Hartmann-test configuration, the calibration of system geometry is required to achieve “null” testing. However, the system miscalibration can introduce a significant systematic error in the testing results. A general double-step calibration method, which is based on the low-order Zernike aberration optimization and high-order aberration separation, is proposed to separate and eliminate the geometrical error due to system miscalibration. Both the numerical simulation and experiments have been performed to validate the feasibility of the proposed calibration method. The proposed method provides a general way for the accurate calibration of system geometrical error, avoids the over-correction and is feasible for the testing of various complex freeform surfaces.
The numerical aperture (NA) and power of diffraction wave in point-diffraction interferometer (PDI) could significantly limit the measurement range of the system. A fiber point-diffraction interferometer with high NA is proposed for the measurement of absolute three-dimensional coordinates. Based on the single-mode fiber with submicron aperture, the diffraction wave with both high NA and high power is obtained, by which the achievable measurement range of the PDI can be extended. A double-iterative method based on Levenbery-Marquardt algorithm is proposed to determine the three-dimensional coordinates under measurement. Numerical simulation and comparison experiments have been carried out to demonstrate the accuracy and feasibility of the proposed PDI system, with both high measurement precision and nice repeatability achieved.
Fixed exposure will lead to underexposure or overexposure of collected flame radiation images using CCD, which has a great influence on the temperature measuring accuracy. A temperature measurement method was proposed by image fusion with multi-exposure, which can eliminate the influence of insufficient underexposure and overexposure. The approach was first to acquire a group of flame radiation images during different exposures. Then a partial region with good exposure effect in each radiation image was obtained by segmentation, with which the complete flame image can be spliced together. An experimental system was built to calibrate the temperature measurement parameters by two-color pyrometry through a blackbody furnace. The relation between exposure time and monochromatic gray level, as well as the relation between the temperature and temperature measurement coefficient were obtained. A candle flame was selected as the measuring object and the complete and accurate flame temperature distribution was acquired following our proposed method. The experimental results show that, compared with the temperature measurement using a single exposure time, our method can effectively avoid the measurement error caused by underexposure and overexposure, and improve the measurement accuracy.