In the current standards, wind loads on lattice transmission tower (LTT) bodies only account for the action of horizontal winds, which may not be suitable for an LTT under the action of extreme winds. The wind load coefficients of LTT bodies subjected the skewed wind with both horizontal and vertical components were measured via several well-designed wind tunnel tests. The test results and standard calculations of the skewed wind load factors (SWLF) at a wind attack angle of 0° were compared and analyzed. A new parameter—combined wind load factor (CWLF) was introduced, and a suggested formula is proposed for it. The results showed that the standard-recommended formula was unable to accurately reflect the characteristics of SWLF, and its calculated results were significantly smaller than the test results, indicating that the actual wind loads were underestimated. The CWLF could correctly describe how wind load factors changed with the yaw angles or the attack angles. The CWLF effectively improved the calculation accuracy of the SWLF, and the absolute error between the calculations and test results under the critical yaw and attack angles was less than 7%.
1 November 2021 in Journal of Physics: Conference Series
At present, the wind tunnel test results will have certain deviation and distortion when the wind tunnel test is conducted on certain mountainous terrain with complex local terrain and large variation of wind field characteristics due to the accuracy range of the measuring instruments used in wind tunnel test. In order to correct and obtain correct wind tunnel test results, the wind tunnel tests and numerical simulations were conducted on a super-large bridge in the mountainous area of Southwest China, and the wind parameters of the wind field at the bridge site were obtained. The CFD results were compared with the wind tunnel test results to confirm the credibility of the CFD results; a method was proposed to correct the deviated wind tunnel test data based on the CFD simulation results; the deviated wind tunnel test data were corrected and predicted with the above method, and a more satisfactory correction result was obtained.
17 August 2024 in Journal of Wind Engineering and Industrial Aerodynamics
Field observations and previous studies have shown that vertical vortex-induced vibration (VIV) of long-span bridge girders may involve the coexistence and competition of two modes within the same lock-in region. Existing wind-tunnel testing approaches, however, have difficulty reproducing this dual-mode behavior in a controlled manner while retaining adequate representation of cross-sectional details. With the Humen Bridge girder as the prototype, a mid-scale dual-mode aeroelastic model comprising a spanwise series of narrow strips was developed by combining an equivalent-girder concept with a two-step distorted-scaling strategy. Synchronous force and vibration measurements across multiple strips were then employed to investigate modal competition within the lock-in region and to evaluate the effects of ancillary components on VIV. The frequencies, equivalent masses, and mode shapes of the two target modes agreed well with their design targets. After conversion to the prototype scale, the lock-in wind-speed ranges and peak amplitudes were broadly consistent with field measurements and previous sectional-model test results, demonstrating that competition between two vertical VIV modes could be reproduced in a controlled manner. The tests further showed that the side maintenance rail increased VIV amplitudes at low wind speeds and reduced the onset wind speed, whereas the middle maintenance rail significantly suppressed the response. The water-filled barriers mainly broadened the low-speed lock-in region and could induce an additional high-speed VIV response.
3 June 2025 in Journal of Wind Engineering and Industrial Aerodynamics