Cristina Pistea

Dr. Cristina Pistea


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
MRMarianne Riou
Marianne Riou
ACAnne-Laure Charles
Anne-Laure Charles
IEIrina Enache
Irina Enache
ECEvrard Charles
Evrard Charles
CPCristina Pistea
Cristina Pistea
BGBernard Geny
Bernard Geny
Peripheral blood mononuclear cells’ (PBMCs) mitochondrial respiration is impaired and likely involved in myocardial injury and heart failure pathophysiology, but its response to acute and severe hypoxia, often associated with such diseases, is largely unknown in humans. We therefore determined the effects of acute hypoxia on PBMC mitochondrial respiration and ROS production in healthy volunteers exposed to controlled oxygen reduction, achieving an inspired oxygen fraction of 10.5%. We also investigated potential relationships with gene expression of key biomarkers of hypoxia, succinate and inflammation, as hypoxia and inflammation share common mechanisms involved in cardiovascular disease. Unlike global mitochondrial respiration, hypoxemia with a spO2 ≤ 80% significantly reduced PBMC complex II respiration (from 6.5 ± 1.2 to 3.1 ± 0.5 pmol/s/106 cell, p = 0.04). Complex II activity correlated positively with spO2 (r = 0.63, p = 0.02) and inversely correlated with the succinate receptor SUCNR1 (r = −0.68), the alpha-subunit of the hypoxia-inducible factor (HIF-1α, r = −0.61), the chemokine ligand-9 (r = −0.68) and interferon-stimulated gene 15 (r = −0.75). In conclusion, severe hypoxia specifically impairs complex II respiration in association with succinate, inflammation and HIF-1α pathway interactions in human PBMCs. These results support further studies investigating whether modulation of complex II activity might modify the inflammatory and metabolic alterations observed in heart failure.

28 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
ECEvrard Charles
Evrard Charles
AAAmina ATTAOUI
Amina ATTAOUI
CPCristina Pistea
Cristina Pistea
IEIrina Enache
Irina Enache
MMMark Marriott
Mark Marriott
BGBernard Geny
Bernard Geny
The continuous monitoring of oxygen saturation (SpO2) and respiratory rates (RRs) are major clinical issues in many cardio-respiratory diseases and have been of tremendous importance during the COVID-19 pandemic. The early detection of hypoxemia was crucial since it precedes significant complications, and SpO2 follow-up allowed early hospital discharge in patients needing oxygen therapy. Nevertheless, fingertip devices showed some practical limitations. In this study, we investigated the reliability of the new Multisense® pulse oximetry system compared to a reference pulse oximeter (Vyntus CPX Pulse Oximeter) during hypoxia. In a population of sixteen healthy male subjects (mean age: 31.5 ± 7.0 years, BMI: 24.9 ± 3.6 kg/m², and 35% with darker skin tones), simultaneous SpO2 and RR measurements were collected over 12.4 h, during which FiO2 was progressively reduced from 21% to 10.5%. The average root mean square error (ARMS) of SpO2 for Multisense® placed on the back and chest was 2.94% and 2.98%, respectively, with permutation testing confirming a significant ARMS below 3.5% for both positions and no statistically significant difference in the ARMS between patch placements. Positive correlations and acceptable accuracy between devices were observed at both locations (r = 0.92, p < 0.001 and r = 0.90, p < 0.001 for back and chest placements, respectively). Bland–Altman analysis further indicated limits of agreement that support consistency across placements, with similar agreement levels noted across skin tones. Similar findings were obtained with the RR measurements. In conclusion, Multisense® demonstrated robust accuracy in measuring SpO2 and RRs during hypoxia in humans comparable to standard hospital-grade equipment. The effectiveness of the findings suggests that this wearable device is a valuable tool for the continuous monitoring of SpO2 and RRs, potentially enhancing patient safety and optimizing hospital resource allocation. Nevertheless, to overcome study limitations and allow generalized use, further work on a larger population sample, including more subjects with a high phototype and desaturation below 80%, would be useful.