Rong Hu

Dr. Rong Hu

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2012 in Energy and Buildings
Verified
Journal Article
Closed access
Rong HuRong Hu
Rong Hu
JNJ.L. Niu
J.L. Niu

14 March 2020 in Energies
Verified
Journal Article
Open access
PDF file
Rong HuRong Hu
Rong Hu
GLGang Liu
Gang Liu
JNJianlei Niu
Jianlei Niu
Cooling load is difficult to predict for a radiant system, because the interaction between a building’s thermal mass and radiation heat gain has not been well defined in a zone with a cooling surface. This study aims to reveal the effect of thermal mass in an external wall on the transmission load in a space with an active cooling surface. We investigated the thermal performances in a typical office building under various weather conditions by dynamic simulation with Energy-Plus. It was found that the thermal mass in the inside concrete layer had positives in terms of indoor temperature performance and energy conservation. The peak cooling load of the hydronic system decreases 28% in the proper operating state, taking into account the effect of the thermal mass in an external wall. Compared to the performances in zones with equivalent convective air systems (CASs), the peak cooling load and the accumulated load of the combined system (radiant system coupled by fresh air system) are higher by 9%–11% and 3%–4%, respectively. The effect of thermal mass is evident in a transient season with mild weather, when the relative effects are about 45% and 60%, respectively, for a building with radiant systems and a building with equivalent CASs.

4 August 2023 in Buildings
Verified
Journal Article
Open access
PDF file
Rong HuRong Hu
Rong Hu
SLSun shi Lin
Sun shi Lin
JLJincan Liang
Jincan Liang
ZZZhiping Zhou
Zhiping Zhou
YYYingde Yin
Yingde Yin
Due to their benefits in interior thermal comfort, energy saving, and noise reduction, radiant cooling systems have received wide attention. Radiant cooling systems can be viewed as a part of buildings’ maintenance structure and a component of cooling systems, depending on their construction. This article reviews studies on heat exchange in rooms utilizing radiant cooling systems, including research on conduction in radiant system structures, system cooling loads, cooling capacity, heat transfer coefficients of cooling surfaces, buildings’ thermal performance, and radiant system control strategy, with the goal of maximizing the benefits of energy conservation. Few studies have examined how radiant cooling systems interact with the indoor environment; instead, earlier research has focused on the thermal performance of radiant cooling systems themselves. Although several investigations have noted variations between the operating dynamics of radiant systems and conventional air conditioning systems, the cause has not yet been identified and quantified. According to heat transfer theory, the authors suggest that additional research on the performance of radiant systems should consider the thermal properties of inactive surfaces and that buildings’ thermal inertia should be used to coordinate radiant system operation.

2 November 2023 in Applied Thermal Engineering
Verified
Journal Article
Closed access
Rong HuRong Hu
Rong Hu
HCHao Chen
Hao Chen
TLTing Lan
Ting Lan
CZChunwei Zhou
Chunwei Zhou
GLGang Liu
Gang Liu

26 April 2025 in Buildings
Verified
Journal Article
Open access
PDF file
YLYi Nong Liu
Yi Nong Liu
LBLufang Bi
Lufang Bi
Rong HuRong Hu
Rong Hu
LYLingjiang Ye
Lingjiang Ye
WZWenheng Zheng
Wenheng Zheng
YLYuncheng Lan
Yuncheng Lan
Tree-lined spaces as informal communication areas and important pathways for pedestrians are the second largest zones on university campuses, and they have a large impact on the microclimate. At present, the effects of the spatial form for tree-lined boulevards on microclimates have not been investigated. Thus, this study applied experimental and simulation methods to investigate the effects of tree-lined boulevards on microclimates in hot summer and cold winter regions. The main meteorological parameters including air temperature, relative humidity, wind speed, and solar radiation of the boulevard were obtained by experiments. Furthermore, the experimental data as a boundary condition were input into ENVI-met software to investigate the effects of the aspect ratio and canopy diameter of double-row open-canopy boulevards on microclimate regulation. The results showed that when the aspect ratio was reduced from 1.5 to 0.9, the temperature and UTCI increased by 0.047 °C and 0.21 °C, while relative humidity decreased by 0.227%. Decreasing the aspect ratio can effectively improve the microenvironment. As the canopy diameter increased from 7 m to 11 m, the temperature and UTCI of the boulevard space decreased by 0.064 °C and 0.45 °C, while relative humidity increased by 0.245%. An increase in canopy diameter is unfavorable to the improvement of microclimates. This study aims to provide a scientific basis for the design and improvement of tree-lined boulevards on university campuses.

9 May 2024 in Buildings
Verified
Journal Article
Open access
PDF file
Rong HuRong Hu
Rong Hu
HWHaolin Wang
Haolin Wang
JLJunqi Liang
Junqi Liang
Xiaoping LiXiaoping Li
Xiaoping Li
WZWenheng Zheng
Wenheng Zheng
GLGang Liu
Gang Liu
Radiant cooling floors combined with ventilation systems have been widely applied in large space buildings. However, there has been a lack of research on system control strategies for their adaptation to weather changes. This study aimed to find control strategies for radiant cooling floors combined with displacement ventilation systems used in large space buildings in order to achieve energy conservation and environmental improvement. Supply air temperature and cooling surface temperature were determined to be the control variables. It was found that cooling capacity of the combined system and the comfort index, PMV (predicted mean vote), were linear in relation to the supply air temperature and cooling surface temperature. The linear equations regarding cooling capacity and PMV were established separately using environment data, and then the optimal region was determined. A case study on Terminal 3 of Xi’an Xianyang International Airport was conducted. The thermal environment was investigated through on-site measurements, questionnaires, and numerical simulations with CFD (computational fluid dynamics). It was found that supply air temperature and cooling surface temperature had a significant impact on PMV, and less impact on the cooling capacity. Therefore, it was determined that the supply air temperature should be altered first when the indoor temperature exceeds the upper limit, and then the cooling surface temperature should be changed if the indoor environment continues to overheat with the supply air temperature set to 18 °C. Thus, the supply air temperature was kept at 18 °C, and the floor surface temperature was set to be 22 °C on a high-temperature day. The average PMV was 0.87, and the cooling capacity of the combined system was 200 W/(m2·K), according to the CFD simulation. In addition, the surface heat transfer coefficient of the cooling floor was found to be 10.26 W/(m2·K). This research provides important references for the design and operational management of radiant cooling floors in large space buildings.