Pawel Kelm

Dr. Pawel Kelm

Lodz University of Technology, Lodz, Poland
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2022 in Applied Energy
Verified
Journal Article
Open access
IWIrena Wasiak
Irena Wasiak
MSMichal Szypowski
Michal Szypowski
PKPawel Kelm
Pawel Kelm
RMRozmysław Mieński
Rozmysław Mieński
AWAndrzej Wędzik
Andrzej Wędzik
PUPrzemysław Urbanek
Przemysław Urbanek

1 April 2022 in Energies
Verified
Journal Article
Open access
PDF file
PKPawel Kelm
Pawel Kelm
IWIrena Wasiak
Irena Wasiak
RMRozmysław Mieński
Rozmysław Mieński
AWAndrzej Wędzik
Andrzej Wędzik
MSMichał Szypowski
Michał Szypowski
KSKrzysztof Szaniawski
Krzysztof Szaniawski
This paper presents the use of real-time digital simulator (RTDS) and hardware-in-the-loop (HIL) methods for the validation of an energy management system designed for real low-voltage (LV) distribution networks with a high penetration of renewable energy sources. The system is used to address voltage violations and current overloading issues and allows the network operator to maintain safe and controllable network operations. The applied control strategy and the system software were verified by means of simulations. In this paper, the next stage of system validation using the HIL method is presented. A testbed was designed and developed to test the operation of prototype controllers of the system in flexible and reproducible conditions before installing them in the network. The presented testing platform not only includes the LV network simulator with the power amplifiers needed for closed-loop setup but also additional elements of a real network to which the system is dedicated, i.e., the advanced metering infrastructure, photovoltaic source, and energy storage inverters and load devices. Furthermore, the real cellular network of the distribution network operator is used in the communication between the controllers. In addition, the article contains discussions on communication issues, including limitations related to selected protocols. Finally, examples of the experimental validation of the controller prototypes are presented.

28 May 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PKPawel Kelm
Pawel Kelm
RMRozmysław Mieński
Rozmysław Mieński
IWIrena Wasiak
Irena Wasiak
Modern consumer installations can be equipped with renewable power sources (RESs) and stationary energy storage systems (ESSs). In addition, electric vehicles (EVs) are expected to become part of such installations in the not-too-distant future. The paper presents the control strategy that allows for efficient energy management and the option of EV “fast-home” charging. The novelty of this approach includes the use of the “time-dependent energy storage” (EV battery) together with ESS and PV sources with the focus on prosumer benefits. All goals can be achieved without the need for extensive expenses in the home electric infrastructure. To enable the synergy effect, it was necessary to develop a controller algorithm that uses the operating status of the prosumer infrastructure (current power generation and consumption), the state of charge of both the stationary storage and the EV battery, and the possibility to control the EV drive inverter during the parking state. The paper presents a developed simulator built in the PSCAD environment and the simulation results.

16 April 2023 in Energies
Verified
Journal Article
Open access
PDF file
RMRozmysław Mieński
Rozmysław Mieński
IWIrena Wasiak
Irena Wasiak
PKPawel Kelm
Pawel Kelm
This paper concerns the mitigation of voltage disturbances deteriorating power quality and disrupting the operation of LV distribution grids due to the high penetration of PV energy sources in prosumer installations. A novel control strategy for 3-phase 4-wire PV inverters is proposed, which ensures the transmission of PV active power and simultaneous compensation of load unbalance and reactive power, making the prosumer installation balanced and purely active. It results in the balance of phase voltages and the mitigation of their variability. Unlike other methods used for voltage regulation in LV grids, the proposed solution contributes to the reduction in losses, is simple, and does not require additional costs. In the paper, a control algorithm for the PV inverter is described. Its effectiveness was tested by simulation using a model of the real LV distribution grid developed in the PSCAD/EMTDC program. The results of the simulations are presented and evaluated.

1 December 2014
Verified
Conference Paper
Closed access
RPRyszard Pawelek
Ryszard Pawelek
PKPawel Kelm
Pawel Kelm
IWIrena Wasiak
Irena Wasiak
This paper present the results of measurements of EV fast charging process in ABB Terra 52 charging station installed in Aleksandrow Lodzki (Poland) and it is impact on the power quality of supplying network. For the reference purposes, the results of AC slow charging measurements were evaluated.

26 March 2024 in Energies
Verified
Journal Article
Open access
PDF file
PKPawel Kelm
Pawel Kelm
RMRozmysław Mieński
Rozmysław Mieński
IWIrena Wasiak
Irena Wasiak
This article proposes a modular system for prosumer installations composed of photovoltaic (PV) panels and energy storage (ES) integrated with the low voltage (LV) network through a common 4-wire AC/DC inverter. The novel idea is a control strategy for the inverter in which additional functionalities are incorporated. Apart from transmitting an active power generated by the PV source, the same inverter is used to manage energy generated by the PV and to compensate for the current unbalance, harmonics (including subharmonics and interharmonics) and reactive power of the prosumer loads. As a result of the algorithm operation, the currents flowing to the prosumer installation are sinusoidal, symmetrical and purely active, which results in voltage balancing and improving voltage waveforms at the point of common coupling (PCC). In this way, with the widespread use of this solution among prosumers, the impact of the prosumer installation on the distribution network is minimized, and power quality (PQ) disturbances such as unacceptable voltage rises, voltage unbalance and harmonics are avoided. The presented approach may be a solution to the problems network operators face nowadays due to the uncontrolled connection of PV sources. The proposed modular system is also beneficial for the prosumer as the instances of unacceptable overvoltage and, consequently, shutdowns of prosumer installations are reduced. The features of the proposed method are shown in relation to other means applied for PQ improvement in the networks with distributed generation. A principle of the control and the involving algorithm for the inverter is presented. The efficiency of the control strategy was tested in a simulation developed in the PSCAD/EMTDC program. The results of simulations are presented, and the proposed solution is concluded.