A finding of reduced aortic-valve leaflet motion was noted on computed tomography (CT) in a patient who had a stroke after transcatheter aortic-valve replacement (TAVR) during an ongoing clinical trial. This finding raised a concern about possible subclinical leaflet thrombosis and prompted further investigation. We analyzed data obtained from 55 patients in a clinical trial of TAVR and from two single-center registries that included 132 patients who were undergoing either TAVR or surgical aortic-valve bioprosthesis implantation. We obtained four-dimensional, volume-rendered CT scans along with data on anticoagulation and clinical outcomes (including strokes and transient ischemic attacks [TIAs]). Reduced leaflet motion was noted on CT in 22 of 55 patients (40%) in the clinical trial and in 17 of 132 patients (13%) in the two registries. Reduced leaflet motion was detected among patients with multiple bioprosthesis types, including transcatheter and surgical bioprostheses. Therapeutic anticoagulation with warfarin, as compared with dual antiplatelet therapy, was associated with a decreased incidence of reduced leaflet motion (0% and 55%, respectively, P=0.01 in the clinical trial; and 0% and 29%, respectively, P=0.04 in the pooled registries). In patients who were reevaluated with follow-up CT, restoration of leaflet motion was noted in all 11 patients who were receiving anticoagulation and in 1 of 10 patients who were not receiving anticoagulation (P<0.001). There was no significant difference in the incidence of stroke or TIA between patients with reduced leaflet motion and those with normal leaflet motion in the clinical trial (2 of 22 patients and 0 of 33 patients, respectively; P=0.16), although in the pooled registries, a significant difference was detected (3 of 17 patients and 1 of 115 patients, respectively; P=0.007). Reduced aortic-valve leaflet motion was shown in patients with bioprosthetic aortic valves. The condition resolved with therapeutic anticoagulation. The effect of this finding on clinical outcomes including stroke needs further investigation. (Funded by St. Jude Medical and Cedars–Sinai Heart Institute; Portico-IDE ClinicalTrials.gov number, NCT02000115; SAVORY registry, NCT02426307; and RESOLVE registry, NCT02318342.)
1 November 2012 in Journal of the American Society of Echocardiography
Background— Tissue Doppler imaging (TDI) detects left ventricular dysfunction in patients with heart failure and normal ejection fraction, but the prognostic significance of left ventricular dysfunction by TDI in the general population is unknown. Methods and Results— Within the Copenhagen City Heart Study, a large community-based population study, cardiac function was evaluated in 1036 participants by both conventional echocardiography and TDI. Averages of peak systolic (s′), early diastolic (e′), and late diastolic (a′) velocities from 6 mitral annular sites were used. TDI was furthermore quantified by a combined index (eas index) of diastolic and systolic performance: e′/(a′×s′). During follow-up (median, 5.3 years), 90 participants died. Left ventricular dysfunction by TDI, in terms of low s′ (hazard ratio, 1.23 per 1-cm/s decrease; P <0.05) and a′ (hazard ratio, 1.20 per 1-cm/s decrease; P =0.001), were significant predictors of death in Cox proportional-hazards models adjusted for clinical variables (age, sex, body mass index, heart rate, hypertension, diabetes mellitus, and ischemic heart disease) and conventional echocardiography. The adjusted hazard ratio for death in the third tertile compared with the first tertile of the combined index of systolic and diastolic performance by TDI was 2.5 ( P <0.005). Conclusions— In the general population, in which most are free of left ventricular systolic dysfunction and restrictive diastolic filling using conventional echocardiographic parameters, left ventricular dysfunction by TDI is a powerful and independent predictor of death, especially when systolic performance and diastolic performance are considered together, recognizing their interdependency and their complex relation to deteriorating cardiac function.
1 June 2016 in Circulation: Cardiovascular Interventions
Background—: The Nordic Aortic Valve Intervention (NOTION) trial was the first to randomize all-comers with severe native aortic valve stenosis to either transcatheter aortic valve replacement (TAVR) with the CoreValve self-expanding bioprosthesis or surgical aortic valve replacement (SAVR), including a lower-risk patient population than previous trials. This article reports 2-year clinical and echocardiographic outcomes from the NOTION trial. Methods and Results—: Two-hundred eighty patients from 3 centers in Denmark and Sweden were randomized to either TAVR (n=145) or SAVR (n=135) with follow-up planned for 5 years. There was no difference in all-cause mortality at 2 years between TAVR and SAVR (8.0% versus 9.8%, respectively; P =0.54) or cardiovascular mortality (6.5% versus 9.1%; P =0.40). The composite outcome of all-cause mortality, stroke, or myocardial infarction was also similar (15.8% versus 18.8%, P =0.43). Forward-flow hemodynamics were improved following both procedures, with effective orifice area significantly more improved after TAVR than SAVR (effective orifice area, 1.7 versus 1.4 cm 2 at 3 months). Mean valve gradients were similar after TAVR and SAVR. When patients were categorized according to Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) (<4% versus ≥4%), there was no statistically significant difference for TAVR and SAVR groups in the composite outcome for low-risk (14.7%, 95% confidence interval, 8.3–21.2 versus 16.8%; 95% confidence interval, 9.7–23.8; P =0.58) or intermediate-risk patients (21.1% versus 27.1%; P =0.59). Conclusions—: Two-year results from the NOTION trial demonstrate the continuing safety and effectiveness of TAVR in lower-risk patients. Longer-term data are needed to verify the durability of this procedure in this patient population. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT01057173.
To test the hypothesis that echocardiographic tissue Doppler imaging (TDI) reveals reduced myocardial function in hypertension, diabetes, and ischaemic heart disease (IHD) in the general population. Within a large, community-based population study, cardiac function was evaluated in 1036 participants by both conventional echocardiography and colour TDI. Peak systolic (s′) and early diastolic (e′) velocities, longitudinal displacement (LD), and the ratio of mitral inflow E-wave to e′ (E/e′) were measured. TDI revealed significantly impaired parameters of systolic and diastolic cardiac function in hypertension [n = 345; LD 10.1 (±standard deviation, SD 2.0 mm), P < 0.001; E/e′ 12.4 (×÷SD 1.4), P < 0.001], diabetes [n = 65; LD 9.8 (±SD 2.2 mm), P < 0.001; E/e′ 12.7 (×÷SD 1.5), P < 0.001], and IHD [n = 93; LD 9.4 (±SD 2.5 mm), P < 0.001; E/e′ 13.0 (×÷SD 1.5), P < 0.001] compared with controls [n = 533; LD 11.4 (±SD 2.0 mm); E/e′ 9.0 (×÷SD 1.3)]. This pattern remained significant after adjusting for age, sex, body mass index, heart rate, and the results of conventional echocardiography. In the general population, persons with hypertension, diabetes, or IHD have impaired cardiac function by TDI independently of the result of conventional echocardiography.