Marcin Abramski

Prof. Dr. Marcin Abramski

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2018 in Archives of Civil and Mechanical Engineering
Verified
Journal Article
Closed access
MAMarcin Abramski
Marcin Abramski

2 June 2010 in Beton- und Stahlbetonbau
Verified
Journal Article
Closed access
PDF file
MAMarcin Abramski
Marcin Abramski
AAAndrej Albert
Andrej Albert
KPKarsten Pfeffer
Karsten Pfeffer
JSJürgen Schnell
Jürgen Schnell

9 April 2010 in Stahlbau
Verified
Journal Article
Closed access
PDF file
MAMarcin Abramski
Marcin Abramski
TFThomas Friedrich
Thomas Friedrich
WKWolfgang Kurz
Wolfgang Kurz
JSJürgen Schnell
Jürgen Schnell

1 May 2020 in Materials
Verified
Journal Article
Open access
PDF file
MAMarcin Abramski
Marcin Abramski
PKPiotr Korzeniowski
Piotr Korzeniowski
KKKrzysztof Klempka
Krzysztof Klempka
The paper presents experimental studies on axially compressed columns made of concrete-filled glass fiber reinforced polymer (GFRP) tubes. The infill concrete was C30/37 according to Eurocode 2. The investigated composite pipes were characterized by different angles of fiber winding in relation to the longitudinal axis of the element: 20, 55 and 85 degrees. Columns of two lengths, 0.4 m and 2.0 m, were studied. The internal diameter and wall thickness of all the pipes were identical and amounted to 200 mm and 6 mm, respectively. The mean values of two mechanical properties, elasticity modulus and compression strength, were determined. These properties were determined for longitudinal compression and for circumferential tension. The graphs of longitudinal and peripheral deformations of polymer shells as a function of load level are presented both for empty tubes and for concrete-filled ones. The results of long-term investigations of three identically made 0.4 m high concrete-filled GFRP tubes are also presented.

1 January 2010
Verified
Conference Paper
Closed access
MAMarcin Abramski
Marcin Abramski
AAAndrej Albert
Andrej Albert
ANAndreas Nitsch
Andreas Nitsch
JSJürgen Schnell
Jürgen Schnell
Two way hollow core slabs with void formers between the upper and lower static reinforcement are getting more and more popular in Germany. The reduction of the dead load of the slab resulting from the cavities allows larger spans compared to solid slabs with the same depth. Since the void formers are spherical or ellipsoid shaped the slab maintains its biaxial strength. However some open questions regarding the bearing behaviour of two way hollow core slabs still prevent a wider spread of these innovative structural elements. The goal of this research project was to answer these open questions.While the bending strength of a two way hollow core slab is almost the same like for a solid slab its shear strength is significantly smaller. Therefore in this research project the shear strength of two way hollow core slabs was investigated. 13 large scale tests and corresponding nonlinear finite element calculations were conducted to prove that the shear strength of a two way hollow core slab is at least 50% of the shear strength of an equivalent solid slab.Another open question was the stiffness of the slab in arbitrary directions which leads to the question whether the internal forces of a two way hollow core slab should be determined like they are determined for a solid slab or rather like they are determined for a ribbed slab. The test and the nonlinear finite element calculations of this research project have shown that it is correct to calculate the internal forces of a two way hollow core slab in the same way like they are calculated for a solid slab.

1 October 2017 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
MAMarcin Abramski
Marcin Abramski
Porous concrete is commonly used in civil engineering due to its good thermal insulation properties in comparison with normal concrete and high compression strength in comparison with other building materials. Reducing of the concrete density can be obviously obtained by using lightweight aggregate (e.g. pumice). The concrete density can be further minimized by using specially graded coarse aggregate and little-to-no fine aggregates. In this way a large number of air voids arise. The aggregate particles are coated by a cement paste and bonded together with it just in contact points. Such an extremely porous concrete, called 'lightweight aggregate concrete with open structure' (LAC), is used in some German plants to produce prefabricated wall components. They are used mainly in hall buildings, e.g. supermarkets. The need of improving thermal insulation properties was an inspiration for the prefabrication plant managers, engineers and a scientific staff of the Technical University of Kaiserslautern / Germany to realise an interesting project. Its aim was to reduce the heat transfer coefficient for the wall components. Three different wall structure types were designed and compared in full-scale laboratory tests with originally produced wall components in terms of load-carrying capacity and stiffness. The load was applied perpendicularly to the wall plane. As the components are not originally used for load-bearing walls, but for curtain walls only, the wind load is the main load for them. The wall components were tested in horizontal position and the load was applied vertically. Totally twelve wall components 8.00 × 2.00 × 0.25m (three for every series) were produced in the prefabrication plant and tested in the University of Kaiserslautern laboratory. The designed and tested components differed from each other in the amount of expanded polystyrene (EPS), which was placed in the plant inside the wall structure. The minimal amount of it was designed in the original wall component type. Besides, two improved types of prefabricated wall had built-in steel lattice girders. The failure mode was the same for all the tested components: diagonal cracks occurred on the sides of each component due to their insufficient shear-force-capacity. The span deflection was measured during all the tests by means of LVDTs. Load-carrying capacities obtained in the tests were for all wall structure types similar and much higher (many times) than internal forces (i.e. bending moments and shear forces) calculated for a wind load acting on a typical hall building according to the German codes. An increased amount of EPS (up to 30 per cent in volume) did not influence significantly the wall structural strength. The use of the steel lattice girders caused some technological problems and led to a quality loss of the produced components. The future use of the lattice girders would require a change in the production process: it would have to be more labour consuming.