Smart City is a cutting edge technology driven city aimed at making our everyday lives safer and more convenient. Like every city it is comprised of structures. To uphold their safety these structures have to undergo periodical maintenance checks. However, checks are done manually, thus consume a significant amount of time and financial resources. Remote Structural Health Monitoring (RSHM) is a perfect solution for a Smart City, however limited research is done in applying Internet of Things (IoT) sensor nodes for permanent RSHM in applications that use bolted joints as a main fastening method. Most of the proposed solutions are not suitable, since either additional structural modifications are required, they violate standards, provide poor wireless communication range or still require human intervention. Therefore, this paper proposes an IoT sensor node named TenSense M30, which leverages Long Range (LoRa) communication technology to enable wide communication coverage and long life for monitoring the health of bolted joints in a Smart City environment. TenSense M30 has a miniature footprint and can be used as an add-on to current structures. Mechanical, hardware and embedded designs are presented and evaluated by means of simulation and practical tests. Results show that TenSense M30 is capable of precisely monitoring the pre-tension load of bolted joints, has a secured non-line of sight communication channel with a distance of 800 meters, has an expected lifetime of greater than 5 years powered by a number of coin cell batteries, and is safe under the pre-tension load.
With the advent of Internet of Things (IoT) a slow shift is happening from manual checks of capital intensive assets such as bridges, wind turbines, etc., where bolted joint is used as a main fastening method, towards unattended Structural Health Monitoring (SHM). Numerous approaches are proposed for monitoring the looseness of bolted joint assemblies, however, the majority of them can only be used for looseness detection purposes and not viable for monitoring since these approaches contain design impracticalities, not scalable or hard to implement outside of the laboratory environment. Furthermore, remote unattended monitoring is still very much in its infancy. Thus, to solve this issue, we propose a TenSense M20, a custom designed smart sensor node for continuous remote SHM of bolted joints. Complete node design is presented. Each aspect of the design is evaluated both by simulation and practical tests. Long Range (LoRa) is used as a means of wireless communication and the network can cover 3.8 km. The results show that TenSense M20 is able to precisely track the pre-tension force of a bolted joint with the approach being robust and scalable. Several transmission scenarios are analyzed and in the worst case scenario the node is estimated to last more than 5 years powered by several LiSOCl2 primary batteries. Received data is securely stored in a blockchain and is easily accessible for services targeting integration with a Smart City.
Pultruded Glass Fiber Reinforced Polymers (PGFRPs) are becoming a new mainstream in civil construction because of their advantageous properties. One of two main elements, glass fibers, have been constructed by unidirectional glass roving in applicate progress. PGFRPs do not have high shear strength, which is determined by another element is the matrix. In the future, the demand for enhanced serviceability of existing PGFRP structures could be seen as unavoidable. Therefore, multi-bolted connection being the most typical type of connecting member, strengthening the connection performance of PGFRPs through connection is necessary. Previous researchers have studied several methods for improving connection capacity, including pasting glass fiber sheets (GFS). However, experimental research is lacking for multi-bolted connection. This study investigated several strategies of specimens, including the quantity of bolts (two bolts, four bolts, and five bolts); the end distance/diameter ratio (e = 2d; e = 3d) under tensile load; and three types of glass fiber sheets (GFS) (0°/90°, ±45° and chopped strand mat (CSM)). The experiment’s results showed the strengthening effects and the failure mode on the specimens. These findings could address the gap in knowledge that needs to be resolved with respect to PGFRPs’ composite design, through evaluation and discussion of their behavior.
In this study, the strengthening effects of different lamination conditions on carbon fiber reinforced polymers (CFRPs) for thin-walled storage tanks (TSTs) subjected to internal pressure under dynamic loads were experimentally investigated. A total of three small-scale models of TSTs were used for the investigation, including non-strengthened specimens, specimens strengthened with 0° CFRP layers, and specimens strengthened with 0°/90° CFRP layers. There were two types of tests for every specimen: the static and dynamic tests. A new experimental method using small steel balls was applied to create internal pressure in the TSTs. The results show that small steel balls could be used to increase the internal pressure compared to a normal liquid. Furthermore, the similarity rules for small-scale TSTs with small steel balls inside were also studied to consider the applicability of the models. The experimental results indicated that the CFRP layer could effectively restrain both static and dynamic hoop strains in the TSTs. Moreover, the CFRP layer could also remarkably reduce the impact of sloshing on the TST shells. The 0° CFRP layer proved to have better effects than the 0°/90° CFRP layers on the strengthening of the TSTs against dynamic loads.