He Zheng

Dr. He Zheng

State Key Laboratory of NBC Protection for Civilian

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2023 in Journal of the American Chemical Society
Verified
Journal Article
Closed access
YLYoucong Li
Youcong Li
JSJian Su
Jian Su
YZYue Zhao
Yue Zhao
LFLiang Feng
Liang Feng
LGLei Gao
Lei Gao
Jing-Lin ZuoJing-Lin Zuo
Jing-Lin Zuo

1 September 2018 in Plant Physiology and Biochemistry
Verified
Journal Article
Closed access
JLJia-Qi Li
Jia-Qi Li
XWXiaoyun Wang
Xiaoyun Wang
XLXinpeng Lin
Xinpeng Lin
GYGuofu Yan
Guofu Yan
LLlun liu
lun liu
Yang-Dong GuoYang-Dong Guo
Yang-Dong Guo

10 July 2020 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
HZHe Zheng
He Zheng
SYSheng-Jiang Yang
Sheng-Jiang Yang
YZYong-Chao Zheng
Yong-Chao Zheng
YCYan Cui
Yan Cui
ZZZhe Zhang
Zhe Zhang
JZJian Zhou
Jian Zhou

30 January 2020 in Nanoscale
Verified
Journal Article
Closed access
PDF file
SYShengjiang Yang
Shengjiang Yang
JLJie Liu
Jie Liu
HZHe Zheng
He Zheng
JZJinyi Zhong
Jinyi Zhong
JZJian Zhou
Jian Zhou
An acetylcholinesterase (AChE)-based electrochemical biosensor, as a promising alternative to detect organophosphates (OPs) and carbamate pesticides, has gained considerable attention in recent years, due to the advantages of simplicity, rapidity, reliability and low cost. The bio-activity of AChE immobilized on the surface and the direct electron transfer (DET) rate between an enzyme and an electrode directly determined the analytical performances of the AChE-based biosensor, and experimental studies have shown that the charged surfaces have a strong impact on the detectability of the AChE-based biosensor. Therefore, it is very important to reveal the behaviour of AChE in bulk solution and on charged surfaces at the molecular level. In this work, the adsorption orientation and conformation of AChE from Torpedo californica (TcAChE) on oppositely charged self-assembled monolayers (SAMs), COOH-SAM and NH2-SAM with different surface charge densities, were investigated by parallel tempering Monte Carlo (PTMC) and all-atom molecular dynamics simulations (AAMD). Simulation results show that TcAChE could spontaneously and stably adsorb on two oppositely charged surfaces by the synergy of an electric dipole and charged residue patch, and opposite orientations were observed. The active-site gorge of TcAChE is oriented toward the surface with the “end-on” orientation and the active sites are close to the surface when it is adsorbed on the positively charged surface and the tunnel cost for the substrate is lower than that on the negatively charged surface and in bulk solution, while for TcAChE adsorbed on the negatively charged surface, the active site of TcAChE is far away from the surface and the active-site gorge is oriented toward the solution with a “back-on” orientation. It suggests that the positively charged surface could provide a better microenvironment for the efficient bio-catalytic reaction and quick DET between TcAChE and the electrode surface. Moreover, the RMSD, RMSF, dipole moment, gyration radius, eccentricity and superimposed structures show that only a slight conformational change occurred on the relatively flexible structure of TcAChE during simulations, and the native conformation is well preserved after adsorption. This work helps us better comprehend the adsorption mechanism of TcAChE on charged surfaces and might provide some guidelines for the development of new TcAChE-based amperometric biosensors for the detection of organophosphorus pesticides.

26 February 2019 in Molecules
Verified
Journal Article
Open access
PDF file
SLShengsong Li
Shengsong Li
YZYongchao Zheng
Yongchao Zheng
WCWeiqiang Chen
Weiqiang Chen
ZMZheng Meiling
Zheng Meiling
HZHe Zheng
He Zheng
CZChong-Lin Zhao
Chong-Lin Zhao
Here, we introduced a novel thiourea-based rhodamine compound as a chromo-fluorogenic indicator of nerve agent Soman and its simulant diethyl chlorophosphate (DCP). The synthesized probe N-(rhodamine B)-lactam-2-(4-cyanophenyl) thiourea (RB-CT), which has a rhodamine core linked by a cyanophenyl thiosemicarbazide group, enabled a rapidly and highly sensitive response to DCP with clear fluorescence and color changes. The detection limit was as low as 2 × 10−6 M. The sensing mechanism showed that opening of the spirolactam ring following the phosphorylation of thiosemicarbazides group formed a seven-membered heterocycle adduct, according to MS analysis and TD-DFT calculations. RB-CT exhibited high detecting selectivity for DCP, among other organophosphorus compounds. Moreover, two test kits were employed and successfully used to detect real nerve agent Soman in liquid and gas phase.

19 November 2024 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
Wen ZhangWen Zhang
Wen Zhang
WSWenhao Sang
Wenhao Sang
YCYan Cui
Yan Cui
HWHongmei Wang
Hongmei Wang
LYLing Yuan
Ling Yuan
HZHe Zheng
He Zheng