Recent therapeutic strategies to suppress restenosis after biliary stent placement are insufficient. Here, we demonstrate the usefulness of a self-expandable metal stent (SEMS), a stent mesh coated with silver nanoparticles (AgNPs), for suppression of both stent-induced tissue hyperplasia and biliary sludge formation in the rabbit bile duct. The AgNP-coated SEMSs were prepared using a simple bio-inspired surface modification process. Then, the prepared SEMSs were successfully placed in 22 of 24 rabbits. Sludge formation in the AgNP-coated SEMS groups was significantly decreased compared to the control group on gross findings. Cholangiographic and histologic examinations demonstrated significantly decreased tissue hyperplasia in the AgNP-coated SEMS groups compared with the control group (p < 0.05 for all). There were no differences between the AgNP-coated SEMS groups (p > 0.05 for all). However, in the group coated with the greatest concentration of AgNPs (Group D), submucosal fibrosis was thicker than in the other AgNP-coated groups (p < 0.05 for all). The AgNP-coated metallic stent mesh significantly suppressed stent-induced tissue hyperplasia and biliary sludge formation in the rabbit bile duct. Taken together, the AgNP coating strategy developed in this study could be widely utilized in non-vascular medical devices for anti-bacterial and anti-inflammatory responses.
This study was conducted to investigate the efficacy of a self-expandable retainer (SER) for endoscopic visualization of the external auditory canal (EAC). Tympanomeatal flap (TMF) elevation was performed in six cadaveric heads. Two different types of SER were placed. The procedural feasibility was assessed by endoscopic images. Technical success rate, procedure time, endoscopy lens cleaning, and presence of mucosal injuries were analyzed. TMF elevation and SER placement were successful in all specimens and there were no procedure-related complications. The mean procedure time with the SERs was significantly shorter than without (p < 0.001). The mean number of times the endoscopy lens was cleaned during the procedure was significantly lower in the SER group (p < 0.001). In the SER group, endoscopy insertion into the EAC was easier without tissue contact with the lens during the TMF elevation compared with the non-SER group. There were no mucosal injuries. SER placement is effective for endoscopic visualization via the expanded and straightened EAC. A fully covered type of SER is preferable. The device can be useful for endoscopic ear surgery, reducing procedure time and reducing the need for endoscopy lens cleaning during the procedure.