Extracellular polymeric substances (EPS) are the main causative agents of membrane fouling, and the use of a hybrid membrane bioreactor (HMBR) can mitigate this by reducing the EPS content. Four bench scale sets of HMBRs were used simultaneously to treat domestic wastewater. The effect of sludge retention times (SRT) on membrane fouling in HMBRs and the underlying mechanism were investigated by comparing and analyzing the changes in sludge load, microbial characteristics, EPS distribution characteristics, and transmembrane pressure under different SRTs. Results revealed that, among the four SRTs (10 d, 20 d, 30 d, and 60 d), the best removal rates of chemical oxygen demand and total nitrogen were observed for an SRT of 30 d, with average removal rates of 95.0% and 57.1%, respectively. The best results for ammonia nitrogen and total phosphorus removal were observed at an SRT of 20 d, with average removal rates of 84.3% and 99.5%, respectively. SRT can affect sludge load by altering the biomass, which significantly impacts the microbial communities. The highest microbial diversity was observed at an SRT of 30 d (with a BOD sludge load of 0.0310 kg/kg∙d), with Sphingobacteriales exhibiting the highest relative abundance at 19.6%. At this SRT setting, the microorganisms produced the least amount of soluble EPS and loosely bond EPS by metabolism, 3.41 mg/g and 4.52 mg/g, respectively. Owing to the reduced EPS content, membrane fouling was effectively controlled and the membrane module working cycle was effectively enhanced up to 99 d, the longest duration among the four SRTs.
A hybrid membrane bioreactor (HMBR) employing activated sludge and biofilm simultaneously is proved to represent a good performance on membrane fouling control compared to conventional membrane bioreactor (CMBR) by reducing extracellular polymeric substances (EPS), especially bound EPS (B-EPS). In order to better understand the mechanism of membrane fouling control by the HMBR in regard of microbial community composition, a pilot scale HMBR operated to treat domestic wastewater for six months, and a CMBR operated at the same time as control group. Results showed that HMBR can effectively control membrane fouling. When transmembrane pressure reached 0.1 MPa, the membrane module in the HMBR operated for about 26.7% longer than that in the CMBR. In the HMBR, the quantity of EPS was significantly lower than that in the CMBR. In this paper, soluble EPS was also found to have a close relationship with cake layer resistance. The species richness and diversity in the HMBR were higher than those in the CMBR, and a certain difference between the compositions of microbial communities in the two reactors was confirmed. Therefore, the difference in microbial community compositions may be the direct reason why EPS in the HMBR was lower than that in the CMBR.