Aleksandar Janjic

Dr. Aleksandar Janjic

University of Niš, Faculty of Electronic Engineering, Niš, Serbia
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2007 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
AJAleksandar Janjic
Aleksandar Janjic
DPDragan S. Popovic
Dragan S. Popovic
This paper presents a methodology for optimal long-term maintenance schedule of distribution networks. The methodology is based on risk management approach and the new model of decoupled risk factors and state transition based on decision tree diagram. Risk approach provides more realistic modeling of component failure and estimation of expected consequences, while decoupled risk factors enable definition of selective plan for preventive actions. The proposed methodology is tested on a real overhead distribution network, but it can be used for other parts of distribution system as well. Obtained results have shown that the expected costs of distribution network maintenance can be reduced and the risk of emerging of significant operation costs minimized, by detailed and realistic modeling of risk factors

1 June 2017 in Electric Power Systems Research
Verified
Journal Article
Closed access
AJAleksandar Janjic
Aleksandar Janjic
LVLazar Velimirovic
Lazar Velimirovic
MSMiomir Stankovic
Miomir Stankovic
APAndrija Petrusic
Andrija Petrusic

29 December 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
APAndrija Petrusic
Andrija Petrusic
AJAleksandar Janjic
Aleksandar Janjic
The increasing electric vehicle fleet requires an upgrade and expansion of the available charging infrastructure. The uncontrolled charging cycles greatly affect the electric grid, and for this reason, renewable energy sources and battery storage are getting incorporated into a hybrid charging station solution. Adding a renewable source and a battery to the charging station can help to “buffer” the power required from the grid, thus avoiding peaks and related grid constraints. To date, the origin of the energy coming from the battery has not been traced. In this paper, a solution of the hybrid electric vehicle charging station coupled with the small-scale photovoltaic system and battery energy storage is proposed to eliminate the adverse effects of uncontrolled electric vehicle charging, with the exact calculation of renewable energy share coming from energy stored in the battery. The methodology for the multicriteria optimization of the charging/discharging schedule of a battery and electric vehicle charging level is based on multi-attribute utility theory. The optimization criteria include the minimization of charging costs, maximization of renewable energy (from both the solar plant and the battery), and the minimization of battery degradation. The problem is solved using a genetic algorithm optimization procedure adapted to the multicriteria optimization function. The methodology is tested on an illustrative example, and it is proven that the decision-maker’s preferences greatly affects the choice of the optimal strategy and the optimal battery capacity.

1 March 2020 in Electric Power Systems Research
Verified
Journal Article
Closed access
AJAleksandar Janjic
Aleksandar Janjic
LVLazar Velimirovic
Lazar Velimirovic

18 August 2021 in Symmetry
Verified
Journal Article
Open access
PDF file
LVLazar Z. Velimirović
Lazar Z. Velimirović
RBRadmila Janković Babić
Radmila Janković Babić
JVJelena Velimirovic
Jelena Velimirovic
AJAleksandar Janjic
Aleksandar Janjic
One way to optimize wastewater treatment system infrastructure, its operations, monitoring, maintenance and management is through development of smart forecasting, monitoring and failure prediction systems using machine learning modeling. The aim of this paper was to develop a model that was able to predict a water pump failure based on the asymmetrical type of data obtained from sensors such as water levels, capacity, current and flow values. Several machine learning classification algorithms were used for predicting water pump failure. Using the classification algorithms, it was possible to make predictions of future values with a simple input of current values, as well as predicting probabilities of each sample belonging to each class. In order to build a prediction model, an asymmetrical type dataset containing the aforementioned variables was used.

1 January 2005 in Acta chirurgica Iugoslavica
Verified
Journal Article
Open access
PDF file
TPTomislav Pejcic
Tomislav Pejcic
JHJ. Hadzi-Djokic
J. Hadzi-Djokic
MAM. Acimovic
M. Acimovic
CTC. Topuzovic
C. Topuzovic
BMB. Milkovic
B. Milkovic
AJAleksandar Janjic
Aleksandar Janjic
Prostate specific antigen (PSA) blood test represents the standard procedure in prostate cancer (CaP) diagnosis and follow-up. However, determination of PSA in the urine, where PSA is present in much higher concentrations than in the blood, still remains in the field of research. Objectives: To determine urinary concentrations of PSA (uPSA) in different groups of patients (pts.), and to estimate is it possible to differentiate benign and malignant prostate diseases and to follow-up the results of treatment. Methods: Between January 2001. and November 2003., urinary concentrations of PSA were determined at 142 pts. divided in seven groups: 1. young and healthy volunteers, 2. "BPH-24": pts. with benign prostatic hyperplasia (BPH) who collected the sample of 24- hour voided urine, 3. "BPH-I": pts. with BPH who collected the first portion of first urinary voiding, 4. "TRUS-CaP": pts. with CaP which gave the first portion of urine just prior to transrectal ultrasound guided prostate biopsy (TRUS- biopsy), 5. "TRUSnon- CaP": pts. who gave first portion of urine prior to TRUS-biopsy, but biopsy did not prove the presence of CaP, 6. "RRP": pts. who underwent radical retropubic prostatectomy (RRP), 7. "AAT": pts. who underwent androgen deprivation therapy. Results: Average uPSA value in the group of young and healthy volunteers, was 13.8+19.6 ng/ml, in "BPH-24": 38.0+ 44.4 ng/ml, in "BPH-I": 140.8+140.9 ng/ml, in "TRUSCaP": 234.8+277.7 ng/ml, in TRUS-non-CaP: 113.1 +148.5 ng/ml, and in the group "RRP": 4.4+4.7 ng/ml. There was no statistically significant difference of average uPSA values between "BPH-I" and "TRUSCaP" groups. The significant difference was found between the group of young volunteers and "BPH-I". In "TRUS-CaP" group, there was strong correlation between tumor size and aggressiveness and uPSA concentration. Finally, PSA and uPSA decline during androgen deprivation therapy, strongly correlated (up to r=0.95). Conclusions: Determination of uPSA cannot differentiate BPH and CaP. However, in the group of pts. with proven localized CaP, uPSA can provide additional information concerning T-staging. Moreover, simultaneous monitoring of PSA and uPSA response on hormonal therapy, can provide an early recognition of androgen-in different CaP (AIPCA) and hormone resistant CaP (HRPCA).