Min Hu

Min Hu


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
BZBingjing Zhao
Bingjing Zhao
HWHong Wang
Hong Wang
NQNing Qiao
Ning Qiao
CWChao Wang
Chao Wang
MHMin Hu
Min Hu

9 October 2017 in Neurochemical Research
Verified
Journal Article
Closed access
PDF file
HHHaitao Huang
Haitao Huang
HLHuawei Liu
Huawei Liu
RYRongzeng Yan
Rongzeng Yan
MHMin Hu
Min Hu

8 July 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HWHong Wang
Hong Wang
BZBingjing Zhao
Bingjing Zhao
CLChangkui Liu
Changkui Liu
CWChao Wang
Chao Wang
XTXinying Tan
Xinying Tan
MHMin Hu
Min Hu
Electron beam melting (EBM) and selective laser melting (SLM) are two advanced rapid prototyping manufacturing technologies capable of fabricating complex structures and geometric shapes from metallic materials using computer tomography (CT) and Computer-aided Design (CAD) data. Compared to traditional technologies used for metallic products, EBM and SLM alter the mechanical, physical and chemical properties, which are closely related to the biocompatibility of metallic products. In this study, we evaluate and compare the biocompatibility, including cytocompatibility, haemocompatibility, skin irritation and skin sensitivity of Ti6Al4V fabricated by EBM and SLM. The results were analysed using one-way ANOVA and Tukey’s multiple comparison test. Both the EBM and SLM Ti6Al4V exhibited good cytobiocompatibility. The haemolytic ratios of the SLM and EBM were 2.24% and 2.46%, respectively, which demonstrated good haemocompatibility. The EBM and SLM Ti6Al4V samples showed no dermal irritation when exposed to rabbits. In a delayed hypersensitivity test, no skin allergic reaction from the EBM or the SLM Ti6Al4V was observed in guinea pigs. Based on these results, Ti6Al4V fabricated by EBM and SLM were good cytobiocompatible, haemocompatible, non-irritant and non-sensitizing materials. Although the data for cell adhesion, proliferation, ALP activity and the haemolytic ratio was higher for the SLM group, there were no significant differences between the different manufacturing methods.

15 January 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RYRongzeng Yan
Rongzeng Yan
DLDanmei Luo
Danmei Luo
HHHaitao Huang
Haitao Huang
RLRunxin Li
Runxin Li
NYNiu Yu
Niu Yu
Qiguo RongQiguo Rong
Qiguo Rong
The study was designed to fulfill effective work-flow to fabricate three-dimensional mesh titanium scaffold for mandibular reconstruction. The 3D titanium mesh scaffold was designed based on a volunteer with whole mandible defect. (1) acquisition of the CT data; (2) design with computer aided design (CAD) and finite element analysis (FEA). The pore size and intervals with the best mechanic strength was also calculated using FEA. (3) fabrication of the scaffold using electron beam melting (EBM); (4) implantation surgery. The case recovered well, without loosening and rejection. Additionally, 12 mandibular defect model beagles were used to verify the results. The model was established via tooth extraction and mandibular resection surgeries, and the scaffold was designed individually based on CT data obtained at 2 weeks after extraction operation. Then scaffolds were fabricated using 3D EBM, and the implantation surgery was performed at 2 months after extraction operation. All the animals healed well after implantation, and the grafted mandibular recovered well with time. The relevant parameters of the grafted mandibular were nearly to the native mandibular at postoperative 12 months. It is feasible to fabricate mesh titanium scaffold for repairing mandibular defects individually using reverse engineering, CAD and EBM techniques.

8 January 2018 in Molecular Medicine Reports
Verified
Journal Article
Open access
PDF file
RLRunxin Li
Runxin Li
HLHuawei Liu
Huawei Liu
HHHaitao Huang
Haitao Huang
WBWenting Bi
Wenting Bi
RYRongzeng Yan
Rongzeng Yan
MHMin Hu
Min Hu
In the present study, the effects of hyaluronic acid (HA) combined with chitosan conduit on peripheral nerve scarring and regeneration were investigated in a rat model of peripheral nerve crush injury. A total of 60 Sprague-Dawley rats were randomly distributed into four groups (15 rats in each group), in which the nerve was either not treated (control group) or treated with chitosan conduit, hyaluronic acid, or chitosan conduit coupled with hyaluronic acid following clamp injury to the sciatic nerve. The surgical sites were evaluated by assessing the sciatic functional index, the degree of scar adhesions, the numbers of myelinated nerve fibers, the average diameter of myelinated nerve fibers and the myelin sheath thickness. Larger epineurial scar thickness was observed in the control groups compared with the treatment groups at 4, 8 and 12 weeks following surgery. There was no significant difference in scar adhesion among the four groups at 4 weeks following surgery. However, animals receiving chitosan coupled with HA demonstrated better neural recovery, as measured by reduced nerve adherence to surrounding tissues, less scar adhesion, increased number of axons, nerve fiber diameter and myelin thickness. In conclusion, the application of chitosan conduit combined with HA, to a certain extent, inhibited sciatic nerve extraneural scaring and adhesion, and promoted neural regeneration and recovery.

24 July 2023 in npj Regenerative Medicine
Verified
Journal Article
Open access
PDF file
YLYongfeng Li
Yongfeng Li
HLHuawei Liu
Huawei Liu
CWChao Wang
Chao Wang
RYRongzeng Yan
Rongzeng Yan
LXLei Xiang
Lei Xiang
MHMin Hu
Min Hu
Bone fusion of defect broken ends is the basis of the functional reconstruction of critical maxillofacial segmental bone defects. However, the currently available treatments do not easily achieve this goal. Therefore, this study aimed to fabricate 3D-printing titanium grid scaffolds, which possess sufficient pores and basic biomechanical strength to facilitate osteogenesis in order to accomplish bone fusion in mandibular segmental bone defects. The clinical trial was approved and supervised by the Medical Ethics Committee of the Chinese PLA General Hospital on March 28th, 2019 (Beijing, China. approval No. S2019–065–01), and registered in the clinical trials registry platform (registration number: ChiCTR2300072209). Titanium grid scaffolds were manufactured using selective laser melting and implanted in 20 beagle dogs with mandibular segmental defects. Half of the animals were treated with autologous bone chips and bone substances incorporated into the scaffolds; no additional filling was used for the rest of the animals. After 18 months of observation, radiological scanning and histological analysis in canine models revealed that the pores of regenerated bone were filled with titanium grid scaffolds and bone broken ends were integrated. Furthermore, three patients were treated with similar titanium grid scaffold implants in mandibular segmental defects; no mechanical complications were observed, and similar bone regeneration was observed in the reconstructed patients’ mandibles in the clinic. These results demonstrated that 3D-printing titanium grid scaffolds with sufficient pores and basic biomechanical strength could facilitate bone regeneration in large-segment mandibular bone defects.