Biological hazardous substances such as certain fungi and bacteria represent a high risk for the broad public if fallen into wrong hands. Incidents based on bio-agents are commonly considered to have unpredictable and complex consequences for first responders and people. The impact of such an event can be minimized by an early and fast detection of hazards. The presented approach is based on optical standoff detection applying laser-induced fluorescence (LIF) on bacteria. The LIF bio-detector has been designed for outdoor operation at standoff distances from 20 m up to more than 100 m. The detector acquires LIF spectral data for two different excitation wavelengths (280 and 355 nm) which can be used to classify suspicious samples. A correlation analysis and spectral classification by a decision tree is used to discriminate between the measured samples. In order to demonstrate the capabilities of the system, suspensions of the low-risk and non-pathogenic bacteriaBacillus thuringiensis,Bacillus atrophaeus,Bacillus subtilis,Brevibacillus brevis,Micrococcus luteus,Oligella urethralis,Paenibacillus polymyxaandEscherichia coli(K12) have been investigated with the system, resulting in a discrimination accuracy of about 90%.
1 January 1995 in Journal of the Chemical Society, Chemical Communications
4-Dimethylaminopyridine-N-oxid 2 and 2′,3′,5′-triacetyladenosine-N1-oxide 4 are partially deoxygenated by dimethyldioxirane (DMD) to the corresponding amines 1 and 3; the formation of singlet oxygen suggests a polar rather than a radical mechanism, in which we propose SN2 attack of the N-oxide on the dioxirane peroxide bond.
Laser-induced fluorescence (LIF) is a well-established technique for monitoring chemical processes and for the standoff detection of biological substances because of its simple technical implementation and high sensitivity. Frequently, standoff LIF spectra from large molecules and bio-agents are only slightly structured and a gain of deeper information, such as classification, let alone identification, might become challenging. Improving the LIF technology by recording spectral and additionally time-resolved fluorescence emission, a significant gain of information can be achieved. This work presents results from a LIF based detection system and an analysis of the influence of time-resolved data on the classification accuracy. A multi-wavelength sub-nanosecond laser source is used to acquire spectral and time-resolved data from a standoff distance of 3.5 m. The data set contains data from seven different bacterial species and six types of oil. Classification is performed with a decision tree algorithm separately for spectral data, time-resolved data and the combination of both. The first findings show a valuable contribution of time-resolved fluorescence data to the classification of the investigated chemical and biological agents to their species level. Temporal and spectral data have been proven as partly complementary. The classification accuracy is increased from 86% for spectral data only to more than 92%.
1 August 1997 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
A new type of unstable resonator, suitable for a laser with a large medium cross section and a small or median output coupling, is presented. The resonator configuration, a modification of a negative-branch confocal unstable resonator, is numerically investigated. The basis of the theory is the Fresnel–Kirchhoff integral equation, and the calculations describe a passive resonator. With respect to output mirror tilting, the calculations confirm that the modified negative-branch confocal unstable resonator is less sensitive to mirror misalignments than the conventional negative-branch confocal unstable resonator. Furthermore, the modified resonator improves the beam quality in comparison with the conventional unstable resonator.