The severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) has a major impact on transplant recipients, with mortality rates up to 20%. Therefore, the effect of established messenger RNA (mRNA)-based SARS-CoV-2 vaccines have to be evaluated for solid organ transplant patients (SOT) since they are known to have poor responses after vaccination. We investigated the SARS-CoV-2 immune response via SARS-CoV-2 IgG detection in 23 renal transplant recipients after two doses of the mRNA-based SARS-CoV-2 vaccine BNT162b2 following the standard protocol. The antibody response was evaluated once with an anti-SARS-CoV-2 IgG CLIA 15.8 +/− 3.0 days after the second dose. As a control, SARS-CoV-2 IgG was determined in 23 healthcare workers (HCW) and compared to the patient cohort. Only 5 of 23 (22%) renal transplant recipients were tested positive for SARS-CoV-2 IgG antibodies after the second dose of vaccine. In contrast, all 23 (100%) HCWs were tested positive for antibodies after the second dose. Thus, the humoral response of renal transplant recipients after two doses of the mRNA-based vaccine BNT162b2 (Pfizer-BioNTech, Kronach, Germany) is impaired and significantly lower compared to healthy controls (22% vs. 100%; p = 0.0001). Individual vaccination strategies might be beneficial in these vulnerable patients.
MRNA-based SARS-CoV-2 vaccines offer a preventive strategy against severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infections that is of interest in the care of patients on hemodialysis (HDP). We measured humoral immune responses in 72 HDP after standard vaccination with two doses of the mRNA-based SARS-CoV-2 vaccine BNT162b2 (Pfizer-BioNTech). Antibody responses were evaluated with an anti-SARS-CoV-2 IgG ChemiLuminescent ImmunoAssay (CLIA) two weeks after the second dose. In addition, SARS-CoV-2 IgG was determined in a control of 16 healthy healthcare workers (HCW). The control group of HCW has shown a strong antibody response with a median (MD (Q1; Q3)) antibody titer of 800.0 AU/mL (520.5; 800.0). In comparison to HCW, HDP under 60 years of age responded equally (597.0 AU/mL (410.5; 800.0), p = 0.051). However, the antibody responses of the HDP negatively correlated with age (r2 = 0.2954 p < 0.0001), leading to significantly lower antibody titers in HDP over 60 years (280.0 AU/mL (45.7; 477.0), p < 0.0001). To thoroughly understand the immunogenicity of the new mRNA-based vaccines in HDP, longitudinal data on the effectiveness and durability of antibody responses are needed. Modifications of immunization schedules should be considered in HDP with low or without antibody responsiveness after standard vaccination to boost immune reactivity and prolong protective effects in these vulnerable patients.
Vaccination against SARS-CoV-2 infection is currently approved and shows favorable outcomes, but little known about antibody responses in solid organ transplant recipients, since these patients are known to have an impaired immune response upon vaccination and have not been included in admission studies. We therefore analyzed immunogenicity in 43 liver transplant (LT) recipients in a median of 15 days (IQR, 12–24) after receiving two doses of the mRNA-based SARS-CoV-2 vaccine BNT162b2 following the standard protocol, and compared these results to a control group consisting of 20 healthcare workers (HCWs). Thirty-four of the 43 (79%) LT recipients developed antibodies, compared to 20 out of 20 (100%) in the control group (p = 0.047). The median SARS-CoV-2 IgG titer was significantly lower in the LT recipients compared to the control group (216 vs. >2080 BAU/mL, p = 0.0001). Age and sex distribution was similar in the LT patients that developed antibodies after vaccination compared to those who did not. Interestingly, the patients who received mycophenolate mofetil exhibited a reduced vaccination response compared to the other LT patients (5 of 11 (45.5%) vs. 29 of 32 (90.6%), p = 0.004). In conclusion, our data reveal lower immunogenicity of SARS-CoV-2 vaccine BNT162b2 in LT patients compared to the control group, but still show superior results compared to other solid organ transplant recipients reported so far.
To analyze and compare the performance of the Simplified-Acute-Physiology-Score (SAPS) 2 and SAPS 3 among intermediate care patients with internal disorders. We conducted a retrospective single-center analysis in patients (n = 305) admitted to an intermediate-care-unit (ImCU) for internal medicine at the University Hospital Essen, Germany. We employed and compared the SAPS 2 vs. the SAPS 3 scoring system for the assessment of disease severity and prediction of mortality rates among patients admitted to the ImCU within an 18-month period. Both scores, which utilize parameters recorded at admission to the intensive-care-unit (ICU), represent the most widely applied scoring systems in European intensive care medicine. The area-under-the-receiver-operating-characteristic-curve (AUROC) was used to evaluate the SAPS 2 and SAPS 3 discrimination performance. Ultimately, standardized-mortality-ratios (SMRs) were calculated alongside their respective 95%-confidence-intervals (95% CI) in order to determine the observed-to-expected death ratio and calibration belt plots were generated to evaluate the SAPS 2 and SAPS 3 calibration performance. Both scores provided acceptable discrimination performance, i.e., the AUROC was 0.71 (95% CI, 0.65–0.77) for SAPS 2 and 0.77 (95% CI, 0.72–0.82) for SAPS 3. Against the observed in-hospital mortality of 30.2%, SAPS 2 showed a weak performance with a predicted mortality of 17.4% and a SMR of 1.74 (95% CI, 1.38–2.09), especially in association with liver diseases and/or sepsis. SAPS 3 performed accurately, resulting in a predicted mortality of 29.9% and a SMR of 1.01 (95% CI, 0.8–1.21). Based on Calibration belt plots, SAPS 2 showed a poor calibration-performance especially in patients with low mortality risk (P<0.001), while SAPS 3 exhibited a highly accurate calibration performance (P = 0.906) across all risk levels. In our study, the SAPS 3 exhibited high accuracy in prediction of mortality in ImCU patients with internal disorders. In contrast, the SAPS 2 underestimated mortality particularly in patients with liver diseases and sepsis.
Different therapeutic apheresis techniques have been clinically tested to delay preterm delivery in the case of eoPE (early-onset preeclampsia). Our study evaluated the feasibility of TPE (therapeutic plasma exchange) compared to standard-of-care treatment. Twenty patients treated with 95 TPE sessions were included in the final analysis and retrospectively matched with 21 patients with comparable placental dysfunction. Gestational age at admission was 23.75 ± 2.26 versus 27.57 ± 2.68 weeks of gestation (WoG) in the control group (p = < 0.001), mean sFlt-1/PlGF ratio was 1946.26 ± 2301.63 versus 2146.70 ± 3273.63 (p = 0.821) and mean sEng was 87.63 ± 108.2 ng/mL versus 114.48 ± 88.78 ng/mL (p = 0.445). Pregnancy was prolonged for 8.25 ± 5.97 days when TPE was started, compared to 3.14 ± 4.57 days (p = 0.004). The median sFlt-1/PlGF Ratio was 1430 before and 1153 after TPE (−18.02%). Median sEng fell from 55.96 ng/mL to 47.62 mg/mL (−27.73%). The fetal survival rate was higher in TPE-treated cases. NICU (Neonatal Intensive Center Unit) stay was in the median of 63 days in the TPE group versus 48 days in the standard-of-care group (p = 0.248). To date, this monocentric retrospective study, reports the largest experience with extracorporeal treatments in eoPE worldwide. TPE could improve pregnancy duration and reduce sFlt-1 and sEng in maternal serum without impairing neonatal outcomes.
SARS-CoV-2 is a worldwide challenge for the medical sector. Healthcare workers (HCW) are a cohort vulnerable to SARS-CoV-2 infection due to frequent and close contact with COVID-19 patients. However, they are also well trained and equipped with protective gear. The SARS-CoV-2 IgG antibody status was assessed at three different time points in 450 HCW of the University Hospital Essen in Germany. HCW were stratified according to contact frequencies with COVID-19 patients in (I) a high-risk group with daily contacts with known COVID-19 patients (n = 338), (II) an intermediate-risk group with daily contacts with non-COVID-19 patients (n = 78), and (III) a low-risk group without patient contacts (n = 34). The overall seroprevalence increased from 2.2% in March–May to 4.0% in June–July to 5.1% in October–December. The SARS-CoV-2 IgG detection rate was not significantly different between the high-risk group (1.8%; 3.8%; 5.5%), the intermediate-risk group (5.1%; 6.3%; 6.1%), and the low-risk group (0%, 0%, 0%). The overall SARS-CoV-2 seroprevalence remained low in HCW in western Germany one year after the outbreak of COVID-19 in Germany, and hygiene standards seemed to be effective in preventing patient-to-staff virus transmission.